188
Views
33
CrossRef citations to date
0
Altmetric
Research Article

Occlusal caries detection and quantification by DIAGNOdent and Electronic Caries Monitor: in vitro comparison

, &
Pages 360-364 | Published online: 02 Jul 2009

  • Marthlar TM. Caries status in Europe and predictions of futuretrends. Caries Res 1990;24:381-98.
  • Majáre I, Källestäl C, Stenlund H, Johansson H. Cariesdevelopment from 11 to 22 years of age: a prospective radiography study. Prevalance and distribution. Caries Res 1998;32:10-6.
  • Wenzel A. Fejerskow O, Kidd E, Joyston-Bechal S, Groeneveld A. Depth of occlusal caries assessed clinically, by conventional film radiographs, and by digitized, processed radiographs. Caries Res 1990;24:327-33.
  • Lussi A. Comparrision of different methoods for the diagnosis of fissure caries without cavitation. Caries Res. 1993;27:409-16.
  • Ie YL, Verdonchot EH. Performance of diagnostic systems in occlusal caries detection compared. Comm Dent OralEpidermiol 1994;22:187-91.
  • Sawle RF, Andlaw RJ. Has occlusal caries become more difficult to diagnose? Br. Dent J 1988;164:209-11.
  • Pitts NB. The diagnosis for dental caries Diagnosis methoods for assessing buccal, lingual and occlusal surface. Dent update 1991;18:393-6.
  • Kidd EAM, Ricketts DNJ, Pitts NB. Occlusal caries diagnosis: a changing challenge for clinicians and epidermiologits. J Dent Res 1993;21:323-31.
  • Angmar-M?nsson B, ten Bosh JJ. Advances in methooss for diagnosing coronal caries: a review. Adv Dent Res 1993;7:70-9.
  • Angmar-M?nsson B, Al-Khateeb S, Tranacus S. Monitoring the caries process optical methods for clinical diagnosis and quantification of enamel caries. Eur J Oral Sci 1996;104:480-5.
  • Pine CM, ten Bosch JJ. Dynamics of and diagnostic methoss for detecting small caries lesions. Caries Res 1996;30:381-8.
  • Ekstrand K, Ricketts DNJ, Kidd EAM. Reproducibility and accuracy of three methods for assessment of demineralization depth on the occlusal surface: an in vitro examination. Caries Res 1997;31:224-31.
  • Huysmans M-CDNJM, Longbottom C, Pitts NB. electrical methods in occlusal caries diagnosis: an in vitro comarison with visual inspection and bitewing radiography. Caries Res 1998;32:324-9.
  • Huysmans M-CDNJM, Longbottom C, Hintze H, Verdonschot EH. Surface-specific electrical occlusal caries diagnosis: reproducibility, correlation with histological lesion depth, and tooth type dependence. Caries Res 1998;32:330-6.
  • Verdonschot EH, Angmar-M?nsson B, ten Bosch JJ, Dcery CH, Huysmans M-CDNJM, Pitts NB, et al. Developments in caries diagnosis and their relationship to treatment decisions and quality of care. Caries Res 1999;33:32-40.
  • Lussi A, Firestone A, Schoenberg V, Hotz P, Stich H. In vivo diagnosis of figure caries using a new electrical resistance monitor. Caries Res 1995;29:81-7.
  • Ie YL, Verdonchot EH, Schaeken MJM, vant Hof MA. Electrical conductance of fissure enamel in recently crupted molar teeth as related to caries status. Caries Res 1995;29:94-9.
  • Ricketts D. Electrical conduction detection methods. In: Stookey G, editor. Early detection of dental caries. Indianapolis, Indiana: 1996. p. 67-80.
  • Hibst R, Gall R. Development of a diode laser-based fluorescence caries detector. Caries Res 1998;32:294.
  • Hibst R, Paulus R, Lussi A. Detection of occlusal caries by lasetr fluorescence: basic and clinical investigation. Med Laser Appl 2001;16:205-13.
  • Hibst R, Paulus R. Caries detection by red excited fluorescence investigation on flurophores. Caries Res 1999;33:295.
  • Hibst R, Paulus R. Molecular basis of red excited caries fluorescence. Caries Res 2000;34:323.
  • Lussi A, Imwinkelried S, Pitts NB, Longbottom C, Reich E. Performance and Reproducibility of laser fluorescence system for detection of occlusal caries in vitro. Caries Res 1999;33:261-6.
  • Shi X-Q, Welander U, Angmar-m?nsson B. Occlusal caries detection with Ka Vo DIAGNOdent and radiographic examination: an in vitro comparison. Caries Res 2000;34:151-8.
  • Attrill DC, Ashley PF. Occlual caries detection in primary teeth: a comparison of DIAGNOdent with conventional methods. Br Dent J 2001;190:440-3.
  • Lussi A, Megert B, Longbottom C, Reich E, Francescut P. Clinical performance of a laser fluorescence device for detection of occlusal caries lesions. Eur J Oral Sci 2001;109:14-9.
  • Shi X-Q, Tranaeus S, Angmar-M?nsson B. Comparision of QLF and DIAGNOdent for quantification of smooth caries. Caries Res 2001;35:21-6.
  • Shi X-Q, Tranaeus S, Angmar-M?nsson B. Validation of DIAGNOdent for quantification of smooth surface caries: an in vitro study. Acta Odontol Scand 2001;59:74-8.
  • Huysmans M-CDNJM. Electrical measurement for early caries detection. In: Stookey G, editor Early detection of dental caries. Indianapolis: 1999. p. 123-42.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.