1,706
Views
39
CrossRef citations to date
0
Altmetric
Original

Poor results from the isoelastic total hip replacement

14-17-year follow-up of 149 cementless prostheses

, , , &
Pages 169-176 | Received 15 Oct 2003, Accepted 19 Jun 2004, Published online: 08 Jul 2009

  • Andrew T A, Flanagan J P, Gerundini M, Bombelli R. The isoelastic, noncemented total hip arthroplasty. Preliminary experience with 400 cases. Clin Orthop 1986; (206): 127–38
  • Archibeck M J, Berger R A, Jacobs J J, Quigley L R, Gitelis S, Rosenberg A G, Galante J O. Second-generation cementless total hip arthroplasty. Eight to eleven-year results. J Bone Joint Surg (Am) 2001; 83: 1666–73
  • Bombelli R, Mathys R. Cementless isoelastic RM total hip prosthesis. J R Soc Med 1982; 75: 588–97
  • Burke D W, O′Connor D, Zalenski E B, Jasty M, Harris W H. Micromotion of cemented and uncemented femoral components. J Bone Joint Surg (Br) 1991; 73: 33–7
  • DeLee J G, Charnley J. Radiographical demarcation of cemented sockets in total hip replacement. Clin Orthop 1976; (121): 20–32
  • Dickob M, Martini T. The cementless PM hip arthroplasty. J Bone Joint Surgery (Br) 1996; 78: 195–9
  • Duffy G P, Berry D J, Rowland C, Cabanela M E. Primary uncemented total hip arthroplasty in patients <40 years old. 10 to 14-year result using first-generation proximally porous-coated implants. J Arthroplasty (Suppl 1) 2001; 16: 140–4
  • Engh C A, Bobyn J D, Glassman A H. Porous coated hip replacement: the factors governing bone ingrowth, stress shielding and clinical results. J Bone Joint Surg (Br) 1987; 69: 45–55
  • Engh A, Culpepper W J, Engh C A. Long-term results of use of th e anatomic medullary locking prosthesis in total hip artroplasty. J Bone Joint Surg (Am) 1997; 79: 177–84
  • Fitzgerald R H Jr, Brindley G W, Kavanagh B F. The uncemented total hip arthroplasty. Intraoperative femoral fractures. Clin Orthop 1988; (235): 61–6
  • Glassman A H, Crowninshield R D, Schenck R, Herberts P. A low stiffness composite biologically fixed prosthesis. Clin Orthop 2001; (393): 128–36
  • Grübl A, Chiari C, Gruber M, Kaider A, Gottsauner-Wolf F. Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up. J Bone Joint Surg (Am) 2002; 84: 425–31
  • Gruen T A, McNeice G M, Amstutz H C. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 1979; (141): 17–27
  • Hardinge K. The direct lateral approach to the hip. J Bone Joint Surg (Br) 1982; 64: 17–19
  • Harris W H. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of results evaluation. J Bone Joint Surg (Am) 1969; 51: 737–55
  • Hartofilakidis G, Karachalios T, Zacharakis N. Charnley low friction arthroplasty in young patients with osteoarthritis. A 12- to 24-year clinical and radiographic follow-up study of 84 cases. Clin Orthop 1997; (341): 51–4
  • Herberts P, Malchau H. Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases. Acta Orthop Scand 2000; 71: 111–21
  • Horne G, Berry N, Collis D. Isoelastic uncemented hip arthroplasty - early experience Aust N Z J Surg. 1987; 57: 461–6
  • Huiskes R, Weinans H, van Rietbergen B. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthop 1992; (274): 124–34
  • Kärrholm J, Anderber C, Snorrason F, Thanner J, Langeland N, Malchau H, Herberts P. Evaluation of a Femoral Stem with Reduced Stiffness. A Randomized Study with Use of Radiostereometry and Bone Densitometry. J Bone Joint Surg (Am) 2002; 84: 1651–8
  • Kawamura H, Dunbar M J, Murray P, Bourne R B, Rorabeck C H. The porous coated anatomic total hip replacement. A ten to fourteen year follow-up study of a cementless total hip arthroplasty. J Bone Joint Surg (Am) 2001; 83: 1333–8
  • Kim Y H, Kim J S, Cho S H. Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis: 10- to 12-year results of prospective and consecutive series. J. Arthroplasty 1999; 14: 538–48
  • Kubo T, Inoue S, Maeda T, Arai Y, Hirakawa K, Wu Y, Suehara M, Ogura T, Hirasawa Y. Cementless Lord total hip arthroplasty: cup loosening common after minimum 10years follow-up of 103 hips. Acta Orthop Scand 2001; 72: 585–90
  • McFarland B, Osborne G. Approach to the hip: a suggested improvement on Koher′s method. J Bone Joint Surg (Br) 1954; 36: 364–7
  • Minovic A, Milošev I, Pisot V, Cör A, Antolic V. Isolation of polyacetal wear particles from periprosthetic tissue of isoelastic femoral stems. J Bone Joint Surg (Br) 2001; 83: 1182–90
  • Morscher E, Mathys R. Total isoelastic hip prosthesis implanted without cement. Initial results. Acta Orthop Belg 1974; 40: 639–47
  • Morscher E, Mathys R. First experiences with a cementless isoelastic total hip prosthesis. Z Orthop Ihre Grenzgeb 1975; 113: 745–9
  • Morscher E W, Dick W, Kernen V. Cementless fixation of polyethylene acetabular components in total hip arthroplasty. Arch Orthop Traumat Surg 1982; 99: 223–30
  • Niinimaki T, Jalovaara P. Bone loss from the proximal femur after arthroplasty with an isoelastic femoral stem. BMD measurements in 25 patients after 9 years. 1995; 66: 347–51
  • Niinimaki T, Puranen J, Jalovaara P. Total hip arthroplasty using isoelastic femoral stems. A seven- to nine-year follow-up in 108 patients. J Bone Joint Surg (Br) 1994; 76: 413–8
  • Paprosky W G, Lawrence J, Cameron H. Femoral defect classification; clinical application. Orthop Rev (Suppl 9) 1990; 19: 9–15
  • Paprosky W G, Perona P G, Laurence J M. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6 year follow-up evaluation. J Arthroplasty 1994; 9: 33–44
  • Pisot V. The evaluation of isoelastic and RCM cementless endoprostheses. Thesis, University of Zagreb, Croatia 1993
  • Rosso R. Five-year review of the isoelastic RM total hip endoprosthesis. Arch Orthop Trauma Surg 1988; 107: 86–8
  • Siebold R, Scheller G, Schrener U, Jani L. Long-term results with the cement-free Spotorno CLS shaft. Orthopade 2001; 30: 317–22
  • Sochart D H, Porter M L. Long-term results of cemented Charnley low-friction arthroplasty in patients aged less than 30 years. J Arthroplasty 1998; 13: 123–31
  • Torchia M E, Klassen R A, Bianco A J. Total hip arthroplasty with cement in patients less than twenty years old. Long-term results. J Bone Joint Surg (Am) 1996; 78: 995–1003
  • Träger D. Results of 5–7 year follow-up of implantation of RM isoelastic hip endoprosthesis. Unfallchirurg 1989; 92: 301–4
  • Trauslen F C, Hassenpfiug J, Hahne H J. Long-term results with cement-free total hip prostheses. Z Orthop Ihre Grenzgeb 2001; 139: 206–11

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.