- Andrew T A, Flanagan J P, Gerundini M, Bombelli R. The isoelastic, noncemented total hip arthroplasty. Preliminary experience with 400 cases. Clin Orthop 1986; (206): 127–38
- Archibeck M J, Berger R A, Jacobs J J, Quigley L R, Gitelis S, Rosenberg A G, Galante J O. Second-generation cementless total hip arthroplasty. Eight to eleven-year results. J Bone Joint Surg (Am) 2001; 83: 1666–73
- Bombelli R, Mathys R. Cementless isoelastic RM total hip prosthesis. J R Soc Med 1982; 75: 588–97
- Burke D W, O′Connor D, Zalenski E B, Jasty M, Harris W H. Micromotion of cemented and uncemented femoral components. J Bone Joint Surg (Br) 1991; 73: 33–7
- DeLee J G, Charnley J. Radiographical demarcation of cemented sockets in total hip replacement. Clin Orthop 1976; (121): 20–32
- Dickob M, Martini T. The cementless PM hip arthroplasty. J Bone Joint Surgery (Br) 1996; 78: 195–9
- Duffy G P, Berry D J, Rowland C, Cabanela M E. Primary uncemented total hip arthroplasty in patients <40 years old. 10 to 14-year result using first-generation proximally porous-coated implants. J Arthroplasty (Suppl 1) 2001; 16: 140–4
- Engh C A, Bobyn J D, Glassman A H. Porous coated hip replacement: the factors governing bone ingrowth, stress shielding and clinical results. J Bone Joint Surg (Br) 1987; 69: 45–55
- Engh A, Culpepper W J, Engh C A. Long-term results of use of th e anatomic medullary locking prosthesis in total hip artroplasty. J Bone Joint Surg (Am) 1997; 79: 177–84
- Fitzgerald R H Jr, Brindley G W, Kavanagh B F. The uncemented total hip arthroplasty. Intraoperative femoral fractures. Clin Orthop 1988; (235): 61–6
- Glassman A H, Crowninshield R D, Schenck R, Herberts P. A low stiffness composite biologically fixed prosthesis. Clin Orthop 2001; (393): 128–36
- Grübl A, Chiari C, Gruber M, Kaider A, Gottsauner-Wolf F. Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up. J Bone Joint Surg (Am) 2002; 84: 425–31
- Gruen T A, McNeice G M, Amstutz H C. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 1979; (141): 17–27
- Hardinge K. The direct lateral approach to the hip. J Bone Joint Surg (Br) 1982; 64: 17–19
- Harris W H. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of results evaluation. J Bone Joint Surg (Am) 1969; 51: 737–55
- Hartofilakidis G, Karachalios T, Zacharakis N. Charnley low friction arthroplasty in young patients with osteoarthritis. A 12- to 24-year clinical and radiographic follow-up study of 84 cases. Clin Orthop 1997; (341): 51–4
- Herberts P, Malchau H. Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases. Acta Orthop Scand 2000; 71: 111–21
- Horne G, Berry N, Collis D. Isoelastic uncemented hip arthroplasty - early experience Aust N Z J Surg. 1987; 57: 461–6
- Huiskes R, Weinans H, van Rietbergen B. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin Orthop 1992; (274): 124–34
- Kärrholm J, Anderber C, Snorrason F, Thanner J, Langeland N, Malchau H, Herberts P. Evaluation of a Femoral Stem with Reduced Stiffness. A Randomized Study with Use of Radiostereometry and Bone Densitometry. J Bone Joint Surg (Am) 2002; 84: 1651–8
- Kawamura H, Dunbar M J, Murray P, Bourne R B, Rorabeck C H. The porous coated anatomic total hip replacement. A ten to fourteen year follow-up study of a cementless total hip arthroplasty. J Bone Joint Surg (Am) 2001; 83: 1333–8
- Kim Y H, Kim J S, Cho S H. Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis: 10- to 12-year results of prospective and consecutive series. J. Arthroplasty 1999; 14: 538–48
- Kubo T, Inoue S, Maeda T, Arai Y, Hirakawa K, Wu Y, Suehara M, Ogura T, Hirasawa Y. Cementless Lord total hip arthroplasty: cup loosening common after minimum 10years follow-up of 103 hips. Acta Orthop Scand 2001; 72: 585–90
- McFarland B, Osborne G. Approach to the hip: a suggested improvement on Koher′s method. J Bone Joint Surg (Br) 1954; 36: 364–7
- Minovic A, Milošev I, Pisot V, Cör A, Antolic V. Isolation of polyacetal wear particles from periprosthetic tissue of isoelastic femoral stems. J Bone Joint Surg (Br) 2001; 83: 1182–90
- Morscher E, Mathys R. Total isoelastic hip prosthesis implanted without cement. Initial results. Acta Orthop Belg 1974; 40: 639–47
- Morscher E, Mathys R. First experiences with a cementless isoelastic total hip prosthesis. Z Orthop Ihre Grenzgeb 1975; 113: 745–9
- Morscher E W, Dick W, Kernen V. Cementless fixation of polyethylene acetabular components in total hip arthroplasty. Arch Orthop Traumat Surg 1982; 99: 223–30
- Niinimaki T, Jalovaara P. Bone loss from the proximal femur after arthroplasty with an isoelastic femoral stem. BMD measurements in 25 patients after 9 years. 1995; 66: 347–51
- Niinimaki T, Puranen J, Jalovaara P. Total hip arthroplasty using isoelastic femoral stems. A seven- to nine-year follow-up in 108 patients. J Bone Joint Surg (Br) 1994; 76: 413–8
- Paprosky W G, Lawrence J, Cameron H. Femoral defect classification; clinical application. Orthop Rev (Suppl 9) 1990; 19: 9–15
- Paprosky W G, Perona P G, Laurence J M. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6 year follow-up evaluation. J Arthroplasty 1994; 9: 33–44
- Pisot V. The evaluation of isoelastic and RCM cementless endoprostheses. Thesis, University of Zagreb, Croatia 1993
- Rosso R. Five-year review of the isoelastic RM total hip endoprosthesis. Arch Orthop Trauma Surg 1988; 107: 86–8
- Siebold R, Scheller G, Schrener U, Jani L. Long-term results with the cement-free Spotorno CLS shaft. Orthopade 2001; 30: 317–22
- Sochart D H, Porter M L. Long-term results of cemented Charnley low-friction arthroplasty in patients aged less than 30 years. J Arthroplasty 1998; 13: 123–31
- Torchia M E, Klassen R A, Bianco A J. Total hip arthroplasty with cement in patients less than twenty years old. Long-term results. J Bone Joint Surg (Am) 1996; 78: 995–1003
- Träger D. Results of 5–7 year follow-up of implantation of RM isoelastic hip endoprosthesis. Unfallchirurg 1989; 92: 301–4
- Trauslen F C, Hassenpfiug J, Hahne H J. Long-term results with cement-free total hip prostheses. Z Orthop Ihre Grenzgeb 2001; 139: 206–11
Free access
Poor results from the isoelastic total hip replacement
14-17-year follow-up of 149 cementless prostheses
Reprints and Corporate Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
To request a reprint or corporate permissions for this article, please click on the relevant link below:
Academic Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
Obtain permissions instantly via Rightslink by clicking on the button below:
If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.