- Aglietti P, Buzzi R, De Felice R, Giron F. The Insall-Burstein total knee replacement in osteoarthritis: a 10-year minimum follow-up. J Arthroplasty 1999; 14: 560–5
- Ahlback S. Osteoarthrosis of the knee. A radiographic investigation. Acta Radiol Diagn (Stockh) 1968, (Suppl 72)
- Bartel D L, Bicknell V L. , Wright T M. The effect of Conformity, thickness, and material on stresses in ultra- high molecular weight components for total joint replacement. J Bone Joint Surg (Am) 1986; 68: 1041–51
- Buechel F F, Pappas M J. Long-term survivorship analysis of cruciate-sparing versus cruciate- sacrificing knee prostheses using meniscal bearings. Clin Orthop 1990, 260: 162–9
- Callaghan J J, Insall J N, Greenwald A S, Dennis D, Komistek R D, Murray D, Bourne R B, Rorabeck C H, Dorr L D. Mobile-bearing knee replacement: concepts and results. Instr Course Lect 2001; 50: 431–49
- Collier J P, Mayor M B, McNamara J L, Surprenant V A, Jensen R E. Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components. Clin Orthop 1991, 273: 232–42
- Ewald F C. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop 1989, 248: 9–12
- Goodfellow J, O'Connor J. The anterior cruciate ligament in knee arthroplasty. A risk-factor with unconstrained meniscal prostheses. Clin Orthop 1992, 276: 245–52
- Grewal R, Rimmer M G, Freeman M A. Early migration of prostheses related to long-term survivorship. Comparison of tibial components in knee replacement. J Bone Joint Surg (Br) 1992; 74(2)239–42
- Hartford J M, Hunt T, Kaufer H. Low contact stress mobile bearing total knee arthroplasty: results at 5 to 13 years. J Arthroplasty 2001; 16: 977–8
- Jones V C, Barton D C, Fitzpatrick D P, Auger D D, Stone M H, Fisher J. An experimental model of tibial counterface polyethylene wear in mobile bearing knees: the influence of design and kinematics. Biomed Mater Eng 1999; 9: 189–96
- Jordan L R, Olivo J L, Voorhorst P E. Survivorship analysis of cementless meniscal bearing total knee arthroplasty. Clin Orthop 1997, 338: 119–23
- Kärrholm J, Borssen B, Lowenhielm G, Snorrason F. Does early micromotion of femoral stem prostheses matter? 4–7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg (Br) 1994; 76: 912–7
- Lafortune M A, Cavanagh P R, Sommer H J, III, Kalenak A. Three-dimensional kinematics of the human knee during walking. J Biomech 1992; 25: 347–57
- Larsen A, Dale K, Eek M. Radiographic evaluation of rheumatoid arthritis and related conditions by standard reference films. Acta Radiol Diagn (Stockh) 1977; 18: 481–91
- Lewandowski P J, Askew M J, Lin D F, Hurst F W, Melby A. Kinematics of posterior cruciate ligament-retaining and -sacrificing mobile bearing total knee arthroplasties. An in vitro comparison of the New Jersey LCS meniscal bearing and rotating platform prostheses. J Arthroplasty 1997; 12: 777–84
- Li P L, Zamora J, Bentley G. The results at ten years of the Insall-Burstein II total knee replacement. Clinical, radiological and survivorship studies. J Bone Joint Surg (Br) 1999; 81: 647–53
- Liau J J, Cheng C K, Huang C H, Lo W H. The effect of malalignment on stresses in polyethylene component of total knee prostheses. A finite element analysis. Clin Biomech. Avon, Bristol 2002; 17: 140–6
- Malone T R, Mc Poil T G, Nitz A J. Orthopaedic and sports physical therapy. Mosby, St. Louis, MO 2002
- Nelissen R G H H. Fundamental aspects of the clinical evaluation of total joint prostheses. The total condylar knee prosthesis. Leiden 1995, Thesis Groen
- Nelissen R G, Valstar E R, Rozing P M. The effect of hydroxyapatite on the micromotion of total knee prostheses. A prospective, randomized, double-blind study. J Bone Joint Surg (Am) 1998; 80: 1665–72
- Perillo-Marcone A, Barrett D S, Taylor M. The importance of tibial alignment: finite element analysis of tibial malalignment. J Arthroplasty 2000; 15: 1020–7
- Pilliar R M, Lee J M, Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous- surfaced implants. Clin Orthop 1986, 208: 108–13
- Puloski S K, McCalden R W, MacDonald S J, Rorabeck C H, Bourne R B. Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris. J Bone Joint Surg (Am) 2001; 83: 390–7
- Ranstam J, Ryd L, Onsten I. Accurate accuracy assessment: review of basic principles. Acta Orthop Scand 2000; 71: 106–8
- Reading A D, McCaskie A W, Gregg P J. The inadequacy of standard radiographs in detecting flaws in the cement mantle. J Bone Joint Surg (Br) 1999; 81: 167–70
- Ryd L, Albrektsson B E, Carlsson L, Dansgard F, Herberts P, Lindstrand A, Regner L, Toksvig-Larsen S. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Joint Surg (Br) 1995; 77: 377–83
- Santavirta S, Nordstrom D, Metsarinne K, Konttinen Y T. Biocompatibility of polyethylene and host response to loosening of cementless total hip replacement. Clin Orthop 1993, 297: 100–10
- Schipplein O D, Andriacchi T P. Interaction between active and passive knee stabilizers during level walking. J Orthop Res 1991; 9: 113–9
- Schmalzried T P, Jasty M, Harris W H. Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg (Am) 1992; 74: 849–63
- Selvik G. Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Acta Orthop Scand, 1989: 1–51, (Suppl 232)
- Søballe K, Hansen E S, Brockstedt-Rasmussen H, Bunger C. Hydroxyapatite coating converts fibrous tissue to bone around loaded implants. J Bone Joint Surg (Br) 1993; 75: 270–8
- Stern S H, Insall J N. Posterior stabilized prosthesis. Results after follow-up of nine to twelve years. J Bone Joint Surg (Am) 1992; 74: 980–6
- Stiehl J B, Dennis D A, Komistek R D, Crane H S. In vivo determination of condylar lift-off and screw-home in a mobile-bearing total knee arthroplasty. J Arthroplasty 1999; 14: 293–9
- Stukenborg-Colsman C, Ostermeier S, Wenger K H, Wirth C J. Relative motion of a mobile bearing inlay after total knee arthroplasty. Dynamic in vitro study. Clin Biomech. Avon, Bristol 2002; 17: 49–55
- Uvehammer J, Kärrholm J. Inducible displacements of cemented tibial components during weight- bearing and knee extension observations during dynamic radiostere-ometry related to joint positions and 2 years history of migration in 16 TKR. J Orthop Res 2001; 19: 1168–77
- Valstar E R. Digital Roentgen Stereophotogrammetry. Development, validation, and clinical application. Leiden University, Den Haag 2001, Thesis
- Valstar E R, Vrooman H A, Toksvig-Larsen S, Ryd L, Nelissen R G. Digital automated RSA compared to manually operated RSA. J Biomech 2000; 33: 593–9
- Vedi V, Williams A, Tennant S J, Spouse E, Hunt D M, Gedroyc W M. Meniscal movement. An invivo study using dynamic MRI. J Bone Joint Surg (Br) 1999; 81: 37–41
- Vis H M. Wear, particles, and physical factors in loosening of hip prostheses. University of Amsterdam, the Netherlands 1997, Thesis
- Vrooman H A, Valstar E R, Brand G J, Admiraal D R, Rozing P M, Reiber J H. Fast and accurate automated measurements in digitized stereophotogrammetric radiographs. J Biomech 1998; 31: 491–8
- Wright T M, Rimnac C M, Stulberg S D, Mintz L, Tsao A K, Klein R W, McCrae C. Wear of polyethylene in total joint replacements. Observations from retrieved PCA knee implants. Clin Orthop 1992, 276: 126–34
- Yu B, Stuart M J, Kienbacher T, Growney E S, An K N. Valgus-varus motion of the knee in normal level walking and stair climbing. jClin Biomech. Avon, Bristol 1997; 12: 286–93
Free access
Comparison of micromotion in mobile bearing and posterior stabilized total knee prostheses
A randomized RSA study of 40 knees followed for 2 years
Reprints and Corporate Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
To request a reprint or corporate permissions for this article, please click on the relevant link below:
Academic Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
Obtain permissions instantly via Rightslink by clicking on the button below:
If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.