REFERENCES
- Barnett , N.W. , Hindson , B.J. , and Lewis , S.W. 1999 . Determination of ranitidine and salbutamol by flow injection analysis with chemiluminescence detection . Anal. Chim. Acta , 384 : 151 – 158 .
- Bergamin-Filho , H. , Zagatto , E.A.G. , Krug , F.J. , and Reis , B.F. 1978 . Merging zones in flow injection analysis. Part 1. Double proportional injector and reagent consumption . Anal. Chim. Acta , 101 : 17 – 23 .
- Borges , E.P. , Fernandes , E.N. , Rocha , F.R.P. , and Reis , B.F. 2002 . Desenvolvimento de um dispositivo de baixo custo para medidas de quimiluminescência . Quim. Nova , 25 : 1191 – 1193 .
- Campins-Falcó , P. , Tortajada-Genaro , L.A. , and Bosch-Reig , F. 2001 . A new flow cell design for chemiluminescence analysis . Talanta , 55 : 403 – 413 .
- Dallas , T. and Dasgupta , P.K. 2004 . Light at the end of the tunnel: Recent analytical application of liquid-core waveguides . Trends Anal. Chem. , 23 : 385 – 392 .
- Dol , I. and Knochen , M. 2004 . Flow-injection spectrophotometric determination of salbutamol with 4-aminoantipiryne . Talanta , 64 : 1233 – 1236 .
- et al. . 2001 . Standard Methods for the Examination of Water and Wastewater . Washington , USA : Am. Pub. Health Assoc .
- Felix , F.S. , Quintino , M.S.M. , Carvalho , A.Z. , Coelho , L.H.G. , Lago , C.L. , and Angnes , L. 2006 . Determination of salbutamol in syrups by capillary electrophoresis with contactless conductivity detection (CE-C4D) . J. Pharm. Biomed. Anal. , 40 : 1288 – 1292 .
- Gordon , G. , Sweetin , D.L. , Smith , K. , and Pacey , G.E. 1991 . Improvements in the N,N-diethyl-p-phenylenediamine method for the determination of free and combined residual chlorine through the use of FIA . Talanta , 38 : 145 – 149 .
- Huclová , J. , Satinský , D. , and Sklenárová , H. 2003. Determination of salbutamol using on-line solid-phase extraction and sequential injection analysis. Comparison of chemiluminescence and fluorescence detection. Anal. Bioanal. Chem. , 376: 448–454.
- Ingle , Jr. , J.D. and Crouch , S.R. 1988 . Spectrochemical Analysis . Englewood , New Jersey : Prentice Hall .
- Isacsson , U. and Wettermark , G. 1976 . The determination of inorganic chlorine compounds by chemiluminescence reactions . Anal. Chim. Acta , 83 : 227 – 239 .
- Karuwan , C. , Mantim , T. , Chaisuwan , P. , Wilairat , P. , Grudpan , K. , Juttangprasert , P. , Einaga , Y. , Chailapakul , O. , Suntornsuk , L. , Anurukvorakun , O. , and Nacapricha , D. 2006 . Pulsed amperometry for anti-fouling of boron-doped diamond in electroanalysis of β-agonists: application to flow injection for pharmaceutical analysis . Sensors , 6 : 1837 – 1850 .
- Mukherji , G. and Aggarwal , N. 1991 . Derivative UV-spectroscopic determination of salbutamol sulphate in the presence of gelatin . Int. J. Pharm. , 71 : 187 – 191 .
- Reynolds , J.E.F. 1993 . Martindale : The Extra Pharmacopoeia . London , UK : The Pharmaceutical Press .
- Rocha , F.R.P. , Ródenas-Torralba , E. , Reis , B.F. , Morales-Rubio , A. , and de la Guardia , M. 2005 . A portable and low cost equipment for flow injection chemiluminescence measurements . Talanta , 67 : 673 – 677 .
- Sadler , N.P. and Jacobs , H. 1995 . Application of the Folin-Ciocalteau reagent to the determination of salbutamol in pharmaceutical preparations . Talanta , 42 : 1385 – 1388 .
- Sanchez , M.A. and Rocha , F.R.P. (in press) . Critical evaluation of a TeflonTM AF-2400 liquid-core waveguide for flow-injection chemiluminescent measurements . Luminescence .
- Shi , Y. , Huang , Y. , Duan , J. , Chen , H. , and Chen , G. 2006 . Field-amplified on-line sample stacking for separation and determination of cimaterol, clenbuterol and salbutamol using capillary electrophoresis . J. Chromatogr., A , 1125 : 124 – 128 .
- Yadamini , Y. Reimann , C.T. , Vatanara , A. , and Jönson , J.A. 2006 . Extraction and preconcentration of salbutamol and terbutaline from aqueous samples using hollow fiber supported liquid membrane containing anionic carrier . J. Chromatogr., A , 1124 : 57 – 67 .
- Zagatto , E.A.G. , Jacintho , A.O. , Mortatti , J. , and Bergamin-Filho , H. 1980 . An improved flow injection determination of nitrite in waters by using intermittent flows . Anal. Chim. Acta , 120 : 399 – 403 .
- Zhou , H. , Zhang , Z. , He , D. , and Xiong , Y. 2005 . Flow-through chemiluminescence sensor using molecularly imprinted polymer as recognition elements for detection of salbutamol . Sens. Actuators, B , 107 : 798 – 804 .