References
- Abowei, J. N., and F. D. Sikoki. 2005. Water pollution management and control. Port Harcourt: Double Trust Publications Company.
- Adeloju, S. B. 2013. Progress and recent advances in phosphate sensors: A review. Talanta 114:191–203. doi:10.1016/j.talanta.2013.03.031
- Alexander, P. W., and J. Koopetngarm. 1987. Flow-injection determination of phosphate species in detergents with a calcium ion-selective electrode. Analytica Chimica Acta 197:353–59. doi:10.1016/s0003-2670(00)84750-9
- Berchmans, S. T., B. Issa, and P. Singh. 2012. Determination of inorganic phosphate by electroanalytical methods: A review. Analytica Chimica Acta 729:7–20. doi:10.1016/j.aca.2012.03.060
- Chaston, J. C. 1965. Reactions of oxygen with the platinum metals. Platinum Metals Review 9:51–56.
- Chen, Z. L., R. DeMarco, and P. W. Alexander. 1997. Flow-injection potentiometric detection of phosphates using a metallic cobalt wire ion-selective electrode. Analytica Chimica Acta 34:93–95. doi:10.1039/a700771j
- Engblom, S. 1999. Determination of inorganic phosphate in a soil extract using a cobalt electrode. Plant and Soil 206:173–79.
- Hanrahan, G., T. M. Salmassi, C. S. Khachikian, and K. L. Foster. 2005. Reduced inorganic phosphorus in the natural environment: significance, speciation and determination. Talanta 66:435–44. doi:10.1016/j.talanta.2004.10.004
- Kasem, K. K., and S. Jones. 2008. Platinum as a reference electrode in electrochemical measurements. Platinum Metals Review 52:100–06. doi:10.1595/147106708x297855
- Kim, J., D. M. Kang, S. C. Shin, M. Y. Choi, J. Kim, S. S. Lee, and J. S. Kim. 2008. Functional polyterthiophene-appended uranyl-salophen complex: Electropolymerization and ion-selective response for monohydrogen phosphate. Analytica Chimica Acta 614:85–92. doi:10.1016/j.aca.2008.03.008
- Lee, W. H., Y. Seo, and P. L. Bishop. 2009. Characteristics of a cobalt-based phosphate microelectrode for in situ monitoring of phosphate and its biological application. Sensors and Actuators B 137:121–28. doi:10.1016/j.snb.2008.10.032
- Marco. 1998. Flow injection potentiometric determination of phosphate in waste waters and fertilisers using a cobalt wire ion-selective electrode. Analyst 123 (7):1635–40.
- Mckelvie, I. D., D. M. W. Peat, and P. J. Worsfold. 1995. Techniques for the quantification and speciation of phosphorus in natural-waters. Analytical Proceedings 32:437–445. doi:10.1039/ai9953200437
- Meruva, R. K., and M. E. Meyerhoff. 1996. Mixed potential response mechanism of cobalt electrode towards inorganic phosphate. Analytical Chemistry 68:2022–26. doi:10.1021/ac951086v
- Midgley, D. 1979. Solid-state ion-selective electrodes for the potentiometric determination of phosphate. Talanta 26:261–66. doi:10.1016/0039-9140(79)80063-6
- Midgley, D. 1986. Sulfate and phosphate ion-selective electrodes. Ion-Selective Electrodes Review 8:3–54.
- Motomizu, S., T. Wakimoto, and K. Toei. 1983. Determination of trace amounts of phosphate in river water by flow-injection analysis. Talanta 30:333–338. doi:10.1016/0039-9140(83)80076-9
- Murphy, J., and H. P. Riley. 1962. A modified single method for the determination of phosphate in natural waters. Analytica Chimica Acta 27:31–36. doi:10.1016/s0003-2670(00)88444-5
- Pierzynski, G., H. Zhang, A. Wolf, P. Kleinman, A. Mallarino, and D. Sullivan. 2005. Phosphorus determination in waters and extracts of soils and by-products: Inductively coupled plasma spectrometry versus colorimetric procedures. SERA-17 policy workgroup paper [Online]. SERA-17. http://www.sera17.ext.vt.edu/Documents/P_Analysis_Comparisons.pdf (accessed March 20, 2012).
- Quintana, J. C., L. Idrissi, G. Palleschi, P. Albertano, A. Amine, M. El Rhazi, and D. Moscone. 2004. Investigation of amperometric detection of phosphate Application in seawater and cyanobacterial biofilm samples. Talanta 63:567–74. doi:10.1016/j.talanta.2003.11.040
- Sims, T. 2000. Soil fertility evaluation. In Hand book of soil science, ed. M. Sumner, 25–65. Boca Raton, London, New York, Washington, DC: CRC Press.
- Thompson, M., and J. N. Walsh. 2003. Handbook of inductively coupled plasma atomic emission spectrometry. Woking, Surrey: Viridian Publishing.
- UK Environmental Agency. 2012. Water quality. Reading, UK: Environmental Agency (Online).
- USEPA, Method 3050. 1989. Acid digestion of sediments, sludge and soils. Test methods for evaluating solid waste, vol. 1A, 3rd ed. Rep EPA/SW-846. Springfield, VA: National Technical Information Service.
- Van Staden, J. F. 1993. Behaviour of silver orthophosphate as the electroactive sensor of a coated tubular solid-state phosphate-selective electrode in flow injection analysis (FIA). South African Journal of Chemistry 46:14–19.
- Warwick, C., A. Guerreiro, and A. Soares. 2013. Sensing and analysis of soluble phosphates in environmental samples: A review. Biosensors and Bioelectronics 41:1–11. doi:10.1016/j.bios.2012.07.012
- Worsfold, P. J., L. J. Gimbert, U. Mankasingh, O. N. Omaka, G. Hanrahan, P. C. F. C. Gardolinski, P. M. Haygarth, B. L. Turner, M. J. Keith-Roach, and I. D. McKelvie. 2005. Sampling, sample treatment and quality assurance issues for the determination of phosphorus species in natural waters and soils. Talanta 66:273–93. doi:10.1016/j.talanta.2004.09.006
- Xiao, D., H. Y. Yuan, J. Li, and R. Q. Yu. 1995. Surface-modified cobalt-based sensor as a phosphate-sensitive electrode. Analytical Chemistry 67:288–91. doi:10.1021/ac00098a009