77
Views
2
CrossRef citations to date
0
Altmetric
Atomic Spectroscopy

Trace Level Direct Determination of Phosphorus in Petroleum Products with High Particulate Content

, , ORCID Icon, ORCID Icon &
Pages 2081-2095 | Received 25 Aug 2020, Accepted 16 Oct 2020, Published online: 29 Oct 2020

References

  • Almagro, B. 2008. Pneumatic nebulizers development based on Flow focusing and Flow blurring technologies for their used in analytical techniques based on ICP-OES/MS. Ph.D. Dissertation. University of Alicante.
  • American Standard Test Method (ASTM) D473-07e1. 2017. Standard Test Method for Sediment in Crude Oils and Fuel Oils by the Extraction Method, www.astm.org [Consulted: 07/10/20].
  • American Standard Test Method (ASTM) D5185-18. 2018. Standard Test Method for Multielement Determination of Used and Unused Lubricating Oils and Base Oils by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES), www.astm.org [Consulted: 07/10/20].
  • American Standard Test Method (ASTM) D7111-15a. 2015. Standard Test Method for Determination of Trace Elements in Middle Distillate Fuels by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES), www.astm.org [Consulted: 07/10/20].
  • American Standard Test Method (ASTM) D7691-16. 2016. Standard Test Method for Multielement Analysis of Crude Oils Using Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES), www.astm.org [Consulted: 07/10/20].
  • Arkis, J. W., and J. K. Carpenter. 1968. Refinary process stream anti-foulant. U.S. Patent Number 3,405,054. USA.
  • Barwick, V. L., and S. L. R. Ellison. 2000. VAM Project 3.2.1 Development and Harmonisation of Measurement Uncertainty Principles, Part(d): Protocol for uncertainty evaluation form validation data, version 5.1.
  • Botto, R. I. 1987. Matrix interferences in the analysis of organic solutions by inductively coupled plasma-atomic emission spectrometry. Spectrochimica Acta Part B: Atomic Spectroscopy 42 (1–2):181–9. doi:10.1016/0584-8547(87)80060-5.
  • Botto, R. I., and J. J. Zhu. 1996. Universal calibration for analysis of organic solutions by inductively coupled plasma atomic spectrometry. Journal of Analytical Atomic Spectrometry 11 (9):675–81. doi:10.1039/ja9961100675.
  • Burgener, J. A., and Y. Makonnen. 2020. Nebulization systems. In Sample introduction systems in ICPMS and ICPOES, 57–142. (D. Beauchemin, Ed.) Amsterdam: Elsevier B.V.
  • Burns, D. T., K. Danzer, and A. Townshend. 2002. Use of the terms “Recovery” and “Apparent recovery” in analytical procedures, (IUPAC recommendations 2002). Pure and Applied Chemistry 74 (11):2201–5. doi:10.1351/pac200274112201.
  • Currie, L. A. 1999. Nomenclature in evaluation of analytical methods, including detection and quantification capabilities (IUPAC Recommendations 1995). Analytica Chimica Acta 391 (2):105–26. doi:10.1016/S0003-2670(99)00104-X.
  • Energy Institute IP 501. 2005. Determination of aluminium, silicon, vanadium, nickel, iron, sodium, calcium, zinc and phosphorus in residual fuel oil by ashing, fusion and inductively coupled plasma emission spectrometry. https://law.resource.org/pub/us/cfr/ibr/003/ei.501.2005.pdf [Consulted on 07/10/20].
  • Gazulla, M. F., M. Rodrigo, M. Orduña, M. J. Ventura, and C. Andreu. 2017a. Determination of phosphorus in crude oil and middle distillate petroleum products by inductively coupled plasma-atomic emission spectrometry. Analytical Letters 50 (15):2465–74. doi:10.1080/00032719.2017.1296853.
  • Gazulla, M. F., M. Rodrigo, M. Orduña, M. J. Ventura, and C. Andreu. 2017b. High precision measurement of silicon in naphthas by ICP-OES using isooctane as diluent. Talanta 164:563–9. doi:10.1016/j.talanta.2016.12.023.
  • Joint Committee for Guides in Metrology.2008. JCGM 100. Evaluation of measurement data – Guide to the expression of uncertainty in measurement.
  • McLean, J., M. G. Minnich, L. A. Iacone, H. Liu, and A. Montaser. 1998. Nebulizer diagnostics: Fundamental parameters, challenges, and techniques on the horizon. Invited lecture. Journal of Analytical Atomic Spectrometry 13 (9):829–42. doi:10.1039/a804202k.
  • Suddendorf, R. F., and K. W. Boyer. 1978. Nebulizer for analysis of high salt content samples with inductively coupled plasma emission spectrometry. Analytical Chemistry 50 (13):1769–71. doi:10.1021/ac50035a014.
  • Todolí, J. L. 1994. Analytical Chemistry Department. Design and characterization of a new pressurized pneumatic nebulizer for ICP-OES. Ph.D. diss., University of Alicante.
  • Todolí, J. L., and J. M. Mermet. 2008. Specifications of a sample introduction system to be used with an ICP. In Liquid sample introduction in ICP spectrometry: A practical guide. 1st ed. Amsterdam: Elsevier Science.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.