15
Views
5
CrossRef citations to date
0
Altmetric
Poster presentations

Determination of chloride in soils by flow injection potentiometric pseudo‐titration

, &
Pages 1437-1445 | Published online: 11 Nov 2008

References

  • Alegret , S. , Alonso , J. , Bartroli , J. , Machado , A. A. S. C. , Lima , J. L. F. C. and Paulis , J. M. 1987 . Construction of equipment for potentiometric determinations in flow injection analysis . Quim. Anal. , 6 : 278 – 292 .
  • Alegret , S. , Lima , J. L. F. C. , Machado , A. A. S. C. , Martinez‐Fabregas , E. and Paulis , J. M. 1987 . A new procedure for construction of mouldable shape membrane ion‐selective electrodes accommodating crystalline sensors dispersed in epoxy resin . Quim. Anal. , 6 : 176 – 191 .
  • Alegret , S. , Florido , A. , Lima , J. L. F. C. and Machado , A. A. S. C. 1989 . Flow‐through tubular iodide and bromide ion‐selective electrodes based on epoxy resin heterogeneous membrane . Talanta , 36 : 825 – 829 .
  • Anderson , R. 1987 . Sample Pretreatment and Separation , London , , England : John Wiley .
  • Ferreira , I. M. P. L. V. O. and Lima , J. L. F. C. 1993 . Tubular electrodes and other devices for potentiometric detection in FIA . J. Flow Inj. Anal. , 1 (1) : 17 – 32 .
  • Ferreira , I. M. P. L. V. O. , Lima , J. L. F. C. and Rangel , A. O. S. S. 1994 . Flow injection titration of chloride in food products with a silver tubular electrode based on an homogeneous crystalline membrane . Food Chem. , 50 : 211 – 217 .
  • Hesse , P. R. 1972 . A Textbook of Soil Chemical Analysis , New York , NY : Chemical Publishing .
  • Hongbo , C. and Junyan , S. 1991 . Potassium sodium chloride integrated micro‐conduits in a potentiometric analytical system . Talanta , 38 (9) : 989 – 993 .
  • Lima , J. L. F. C. and Rangel , A. O. S. S. 1989 . Chloride pseudotitration in wines by FIA with a Ag2S/Ag tubular electrode as detector . J. Food Comp. Anal. , 2 : 356 – 363 .
  • Lima , J. L. F. C. and Rocha , L. S. M. 1990 . FIA tubular potentiometric detectors based on homogeneous crystalline membranes. Their use in the determination of chloride and sulfide ions in water . Int. J. Environ. Anal. Chem. , 38 : 127 – 133 .
  • Ramsing , A. U. , Ruzicka , J. and Hansen , E. H. 1981 . The principles and theory of high‐speed titrations by flow injection analysis . Anal. Chim. Acta , 129 : 1 – 17 .
  • Sekerka , I. and Lechner , J. F. 1978 . Ion selective electrode for determination of chloride ion in biological materials, food products, soils and waste waters . J. Assoc. Off. Anal. Chem. , 61 (6) : 1493 – 1495 .
  • Selmer‐Olsen , A. R. and Oien , A. 1973 . Determination of chloride in aqueous soil extracts and water samples by means of a chloride‐selective electrode . Analyst , 98 : 412 – 415 .
  • Sikora , F. J. and Stevenson , F. J. 1987 . Interference of humic substances on chloride analysis using the chloride ion‐selective electrode . Soil. Sci. Soc. Amer. J. , 51 : 924 – 929 .
  • Valcárcel , M. and Luque de Castro , M. D. 1987 . Flow‐Injection Analysis: Principles and Applications , New York , NY : John Wiley .
  • To whom correspondence should be addressed.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.