References
- Hubbell JH, Seltzer SM. Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients from 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest. The Physical Measurement Laboratory; 2010. Available from: http://www.nist.gov/pml/data/xraycoef/index.cfm.
- Birch R, Marshall M. Computation of Bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector. Phys Med Biol. 1979;24:505–517.
- Brooks RA, Di Chiro G. Beam hardening in X-ray reconstructive tomography. Phys Med Biol. 1976;21:390–398.
- Xu C, Danielsson M, Karlsson S, Svensson C, Bornefalk H. Preliminary evaluation of a silicon strip detector for photon-counting spectral CT. Nucl Instruments Methods Phys Res A. 2012;677:45–51.
- Kanno I, Imamura R, Mikami K, Uesaka A, Hashimoto M, Ohtaka M, Ara K, Nomiya S, Onabe H. A current mode detector for unfolding X-ray energy distribution. J Nucl Sci Technol. 2008;45:1165–1170.
- Imamura R, Mikami K, Minami Y, Kanno I, Ohtaka M, Hashimoto M, Ara K, Onabe H. Unfolding method with X-ray path length-dependent response functions for computed tomography using X-ray energy information. J Nucl Sci Technol. 2010;47:1075–1082.
- Kanno I, Imamura R, Yamashita Y, Ohtaka M, Hashimoto M, Ara K, Onabe H. Using energy-resolved X-ray computed tomography with a current mode detector to distinguish materials. Jpn J Appl Phys. 2014;53: 056601–056604.
- Yamashita Y, Kimura M, Kitahara M, Hamaguchi T, Kanno I, Ohtaka M, Hashimoto M, Ara K, Onabe H. Measurement of effective atomic numbers using energy-resolved computed tomography. J Nucl Sci Technol. 2014;51:1256–1263.
- Yamashita Y, Shima K, Kanno I, Ohtaka M, Hashimoto M, Ara K, Onabe H. Low-dose exposure energy-resolved X-ray computed tomography using a contrast agent with a high-energy K-edge. J Nucl Sci Technol. 2014;51:91–97.
- Shinsho K, Kawaji Y, Otsubo K, Koba Y, Wakabayashi G, Matsumoto K, Ushiba H. Thermoluminescence properties of commercial Al2O3 ceramics plate (Kyocera corp., A476). Radiat Meas., submitted.
- Shinsho K, Koba Y, Wakabayashi G, Tamatsu S, Fukuda S, Morimoto R, Maruyama D, Saitoh H, Sakurai N. Basic characteristics of tissue-equivalent phantom thermoluminescence slab dosimeter using new TL phosphor Li3B7012:Cu. Radiat Meas. 2014;62:15–21.
- McElroy W, Berg S, Crockes T, Hawkins G. A computer-automated iterative method for neutron flux spectra determination by foil activation. Albuquerque (NM): Air Force Weapons Laboratory; 1967. p. 8–16.
- Shepp LA, Logan BF. Fourier reconstruction of a head section. IEEE Trans Nucl Sci. 1974;NS21:21–43.