501
Views
1
CrossRef citations to date
0
Altmetric
Review

Attenuation correction of polychromatic L-shell X-ray fluorescence computed tomography imaging

ORCID Icon, , &
Pages 376-384 | Received 13 Jul 2018, Accepted 19 Feb 2019, Published online: 01 Mar 2019

References

  • Bazalova-Carter M. The potential of L-shell X-ray fluorescence CT (XFCT) for molecular imaging. Br J Radiol. 2015;88:20140308.
  • Simionovici A, Chukalina M, Schroer C, et al. High-resolution X-ray fluorescence microtomography of homogeneous samples. IEEE Trans Nucl Sci. 2000;47:2736–2740.
  • Cheong SK, Jones BL, Siddiqi AK, et al. X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp X-rays. Phys Med Biol. 2010;55:647–662.
  • Manohar N, Reynoso FJ, Diagaradjane P, et al. Quantitative imaging of gold nanoparticle distribution in a tumor-bearing mouse using benchtop X-ray fluorescence computed tomography. Sci Rep. 2016;6:22079.
  • Ricketts K, Guazzoni C, Castoldi A, et al. A bench-top K X-ray fluorescence system for quantitative measurement of gold nanoparticles for biological sample diagnostics. Nucl Instrum Methods Phys Res A. 2016;816:25–32.
  • Yoon C, Kim Y, Lee W. 3D non-destructive fluorescent X-ray computed tomography with a CdTe array. IEEE Trans Nucl Sci. 2016;63:1844–1853.
  • Deng B, Yang Q, Xie H-L, et al. First X-ray fluorescence CT experimental results at the SSRF X-ray imaging beamline. Chin Phys C. 2011;35:402–404.
  • Bazalova M, Ahmad M, Pratx G, et al. L-shell X-ray fluorescence computed tomography (XFCT) imaging of Cisplatin. Phys Med Biol. 2014;59:219–232.
  • Chen WR, Ren L, Wu D, et al. Background estimation methods for quantitative X-ray fluorescence analysis of gold nanoparticles in biomedical applications. Proc SPIE. 2014;8944:89440H.
  • Yang Q, Deng B, Du G, et al. X-ray fluorescence computed tomography with absorption correction for biomedical samples. X-Ray Spectrom. 2014;43:278–285.
  • Huang R, Limburg K, Rohtla M. Quantitative X-ray fluorescence computed tomography for low-Z samples using an iterative absorption correction algorithm. AIP Adv. 2017;7:055111.
  • Liu L, Huang Y, Xu Q, et al. Attenuation correction of L-shell X-ray fluorescence computed tomography imaging. Chin Phys C. 2015;39:038203.
  • Jones BL, Cho SH. The feasibility of polychromatic cone-beam X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects: a Monte Carlo study. Phys Med Biol. 2011;56:3719–3730.
  • Li L, Zhang S, Li R, et al. Full-field fan-beam X-ray fluorescence computed tomography with a conventional X-ray tube and photoncounting detectors for fast nanoparticle bioimaging. Opt Eng. 2017;56:043106.
  • Jiang S, He P, Deng L, et al. Monte Carlo simulation for polychromatic X-ray fluorescence computed tomography with sheet-beam geometry. Int J Biomed Imaging. 2017;2017:1–10.
  • Jiang S, Wei B, Feng P, et al. Numerical and Monte Carlo simulation on X-ray fluorescence computed tomography with self-absorption correction. J Med Imaging Health Inf. 2016;6:1720–1726.
  • La Rivière PJ, Vargas PA. Monotonic penalized-likelihood image reconstruction for X-ray fluorescence computed tomography. IEEE Trans Med Imaging. 2006;25:1117–1129.
  • Leroux J. Method for finding mass-absorption coefficients by empirical equations and graphs. Adv X-Ray Anal. 1962;5:153–160.
  • Wieczorek H. The image quality of FBP and MLEM reconstruction. Phys Med Biol. 2010;55:3161–3176.
  • Hebert TJ, Leahy R. Fast methods for including attenuation in the EM algorithm. IEEE Trans Nucl Sci. 1990;37:754–758.
  • Agostinelli S, Allison J, Amako K, et al. Geant4—a simulation toolkit. Nucl Instrum Methods Phys Res A. 2003;506:250–303.
  • Allison J, Amako K, Apostolakis J, et al. Geant4 developments and applications. IEEE Trans Nucl Sci. 2006;52:270–278.
  • Kadri O, Ivanchenko VN, Gharbi F, et al. GEANT4 simulation of electron energy deposition in extended media. Nucl Instrum Methods Phys Res A. 2007;258:381–387.
  • Chauvie S, Guatelli S, Ivanchenko V, et al. Geant4 low energy electromagnetic physics. IEEE Nucl Sci Symp Conf Rec. 2004;3:1881–1885.
  • Miceli A, Thierry R, Bettuzzi M, et al. Comparison of simulated and measured spectra of an industrial 450kV X-ray tube. Nucl Instrum Methods Phys Res, Sect A. 2007;580:123–126.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.