2
Views
3
CrossRef citations to date
0
Altmetric
Original Articles

Quantitative Microwave Tomography for Non-invasive Control of Hyperthermia. Preliminary Numerical ResultsFootnote

, , , , , & show all
Pages 149-153 | Published online: 21 Jul 2016

References

  • Bolomey, J. Ch., Peronnet, G., Jofre, L., “On the possible use of active microwave imaging for remote thermal sensing,” IEEE Trans. Microwave Theory and Techniques, MTT-31, 9, 777-781 (1983).
  • Guo, T. C., Guo, W. W„ Larsen, L. E., “A local field study of a water-immersed microwave antenna array for medical imagery and therapy,” IEEE Trans. Microwave Theory and Techniques, MTT-32, 10, 844-854 (1984).
  • Miyakawa, M., “A study of the temperature dependency of the permittivity of biological tissues,” 5th International Symp. on Hyperthermic Oncology, p 287, Kyoto, August 29-September 3, 1988.
  • Lin, J. C., “Frequency optimization for microwave imaging in biological tissues,” Proc IEEE, 73, 374-375 (1985).
  • Gaboriaud, G„ Lavergne, C., Bolomey, J. Ch., Hawley, M. S., Berthaud, P., Gau- therie, M., Lavoine C., “Microwave tomography in non-invasive control of hyperthermia,” Proc. 9-th IEEE, EMB-S Int. Symp., Boston, 1618-1619, Nov. 1987.
  • Bolomey, J. Ch., Hawley, M. S., Talhouet, H. de, Lavergne, C., Gaboriaud, G., “Comparison of active and passive microwave imaging for non-invasive thermal sensing during hyperthermia,” Proc. 9-th IEEE EMB-S Int. Symp., Boston, 1933-1934, Nov. 1987.
  • Gaboriaud, G., Bolomey, J. Ch., Pichot, Ch., “Control of deep hyperthermia by means of active microwave imaging,” 10th ESHO Conference, Amsterdam, 22, September 1989.
  • Gaboriaud, G., Bolomey, J. Ch., “2.45 GHz microwave camera for biomedical applications,” Technical report, Institut Curie/ Ecole Superieure d’Electricite, January 1989.
  • Broquetas, A., Ferrando, M., Rius, J. M„ Jofre, L. de los Reyes, E., Cardama, A„ Elias, A., Ibanez, J., “Temperature and permittivity measurements using a cylindrical microwave imaging system,” 17th European Microwave Conference, Rome, 892-895, September 1987.
  • Yamaura, L, “Non-invasive thermometry using microwave transmision CT,” Auto- medica, 8, 233-246 (1987).
  • Mueller, R. K., Kaveh, M., Wade, G., “Reconstructive tomography and applications to ultrasounds,” Proc. IEEE, 67, 567-587 (1979).
  • Pichot, Ch., Jofre, L„ Peronnet, G., Bolomey, J. Ch., “Active microwave imaging of inhomogeneous bodies,” IEEE Trans. Antemías and Propagation, AP-33, 4, 416-425 (1985).
  • Rius, J. M., Ferando, M., Jofre, L, Broque¬tas, A., “Microwave tomography: an algor¬ithm for cylindrical geometries,” Electronics Letters, 23, 564-565 (1987).
  • Ermert, H„ Dohlus, M., “Microwave dif¬fraction tomography of cylindrical objects using 3-dimensional wave-fields,” NTZ Ar¬chili, 8, 111-117 (1986).
  • Joachimowicz, N., Thesis, University of Paris, January 1990.
  • Barber, D. C, “A review of image recon-struction techniques for electrical impe¬dance tomography,” Medical Physics, 16, 162-169 (1989).
  • Wang, Y. M„ Chew, W. C, “An iterative solution of the two-dimensional electro-magnetic inverse scattering problem,” Int. J. Imaging Systems and Technology, 1, 100-108 (1989).
  • Tan, D. G. H., Murch, R. D„ Bates, R. H. T. “Inverse scattering for penetrable objects,” URSI Int. Symp., Stockholm, August 1989, 160-162. ‘
  • Ney, M. M„ Smith, A. M., Stuchly, S. S., “A solution of electromagnetic imaging using pseudo-inverse transformation,” IEEE Trans. Medical Imaging, MI-3, 155-163 (1984).
  • Schueller, M„ Chaloupka, H., “Improved reconstruction in diffraction tomography by means of a non-linear scattering model,” URSI Int. Symp., Stockholm, August 1989, 584-586.
  • Habbashy, T. M., Dudley, D. G., “Simulta-neous inversion of permittivity and con-ductivity profiles using a renormalized source-type integral equation approach,” URSI Int. Symp., Stockholm, August 1989, 578-580.
  • Caorsi, S., Gragnani, G. L, Pastorino, M., “Electromagnetic vision-oriented numerical solution to three dimensional inverse scat-tering,” Radio Science, 23, 1094-1106 (1988).
  • Guo, T. C., Guo, W. W„ “Physics of image formation by microwave scattering,” Medi¬cal Imaging, SPIE, Proc., 767, n°2.
  • Hugonin, j. P„ Pichot, Ch., Joachimowicz, N., “Quantitative reconstruction of complex permittivity distributions by means of microwave tomography,” RCP-264, Mont-pellier, December 1990, to be published by Springer Verlag.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.