References
- V. SCHÖNFELDER, A. HIRNER, and K. SCHNEIDER, “A Telescope for Soft Gamma Ray Astronomy,” Nucl. Instrum. Methods, 107, 2, 385 (1973); https://doi.org/10.1016/0029-554X(73)90257-7.
- R. TODD, J. NIGHTINGALE, and D. EVERETT, “A Proposed Gamma Camera,” Nature, 251, 132 (1974); https://doi.org/10.1038/251132a0.
- V. SCHONFELDER et al., “The Imaging Compton Telescope Comptel on the Gamma Ray Observatory,” IEEE Trans. Nucl. Sci., 31, 1, 766 (1984); https://doi.org/10.1109/TNS.1984.4333363.
- R. ANDRITSCHKE et al., “The Compton and Pair Creation Telescope MEGA,” Exp. Astron., 20, 1, 395 (2006); https://doi.org/10.1007/s10686-006-9040-7.
- S. WATANABE et al., “The Si/CdTe Semiconductor Compton Camera of the ASTRO-H Soft Gamma-Ray Detector (SGD),” Nucl. Instrum. Methods Phys. Res. A, 765, 192 (2014); https://doi.org/10.1016/j.nima.2014.05.127.
- T. KAMAE, N. HANADA, and R. ENOMOTO, “Prototype Design of Multiple Compton Gamma-Ray Camera,” IEEE Trans. Nucl. Sci., 35, 1, 352 (1988); https://doi.org/10.1109/23.12741.
- T. O. TÜMER, S. YIN, and S. KRAVIS, “A High Sensitivity, Electronically Collimated Gamma Camera,” IEEE Trans. Nucl. Sci., 44, 3, 899 (1997); https://doi.org/10.1109/23.603774.
- A. STUDEN et al., “First Coincidences in Pre-Clinical Compton Camera Prototype for Medical Imaging,” Nucl. Instrum. Methods Phys. Res. Sec. A, 531, 1, 258 (2004); https://doi.org/10.1016/j.nima.2004.06.014.
- S. W. PETERSON, D. ROBERTSON, and J. POLF, “Optimizing a Three-Stage Compton Camera for Measuring Prompt Gamma Rays Emitted During Proton Radiotherapy,” Phys. Med. Biol., 55, 22, 6841 (2010); https://doi.org/10.1088/0031-9155/55/22/015.
- J. C. POLF et al., “Imaging of Prompt Gamma Rays Emitted During Delivery of Clinical Proton Beams with a Compton Camera: Feasibility Studies for Range Verification,” Phys. Med. Biol., 60, 18, 7085 (2015); https://doi.org/10.1088/0031-9155/60/18/7085.
- J. KATAOKA et al., “Handy Compton Camera Using 3D Position-Sensitive Scintillators Coupled with Large-Area Monolithic MPPC Arrays,” Nucl. Instrum. Methods Phys. Res. Sec. A, 732, 403 (2013); https://doi.org/10.1016/j.nima.2013.07.018.
- Y. SHIKAZE et al., “Field Test Around Fukushima Daiichi Nuclear Power Plant Site Using Improved Ce: Gd3(Al, Ga)5O12 Scintillator Compton Camera Mounted on an Unmanned Helicopter,” J. Nucl. Sci. Technol., 53, 12, 1907 (2016); https://doi.org/10.1080/00223131.2016.1185980.
- E. A. WULF et al., “A Silicon Compton Imager,” Nuclear Science Symp. Conf. Record, 2005 IEEE, Vol. 1, p. 1, IEEE (2005); https://doi.org/10.1109/NSSMIC.2005.1596195.
- S. JAN et al., “GATE: A Simulation Toolkit for PET and SPECT,” Phys. Med. Biol., 49, 19, 4543 (2004); https://doi.org/10.1088/0031-9155/49/19/007.
- S. H. LEE et al., “CIS: A GUI-Based Software System for Monte Carlo Simulation of Compton Camera,” Nucl. Technol., 168, 1, 55 (2009); https://doi.org/10.13182/NT09-A9101.
- G. SCHMID et al., “Gamma-Ray Compton Camera Imaging with a Segmented HPGe,” Nucl. Instrum. Methods Phys. Res. Sec. A, 459, 3, 565 (2001); https://doi.org/10.1016/S0168-9002(00)01028-7.
- B. F. PHLIPS et al., “Comparison of Shielded Uranium Passive Gamma-Ray Detection Methods,” Proc. of SPIE, the Int. Society for Optical Engineering, p. 62130H–1, Society of Photo-Optical Instrumentation Engineers (2006).
- E. A. WULF et al., “Compton Imager for Detection of Special Nuclear Material,” Nucl. Instrum. Methods Phys. Res. Sec. A, 579, 1, 371 (2007); https://doi.org/10.1016/j.nima.2007.04.085.
- J. D. KURFESS et al., “Compton Imager Using Room Temperature Silicon Detectors,” Nucl. Instrum. Methods Phys. Res. Sec. A, 579, 1, 367 (2007); https://doi.org/10.1016/j.nima.2007.04.077.
- E. A. WULF et al., “Thick Silicon Strip Detector Compton Imager,” IEEE Trans. Nucl. Sci., 51, 5, 1997 (2004); https://doi.org/10.1109/TNS.2004.835904.
- S. FETTER et al., “Detecting Nuclear Warheads,” Sci. Glob. Sec., 1, 3–4, 225 (1990); https://doi.org/10.1080/08929889008426333.
- S. AGOSTINELLI et al., “GEANT4—A Simulation Toolkit,” Nucl. Instrum. Methods Phys. Res. Sec. A, 506, 3, 250 (2003); https://doi.org/10.1016/S0168-9002(03)01368-8.