References
- Rose JS, Nanna M, Rahimtoola SH, et al. Accuracy of determination of changes in cardiac output by transcutaneous continuous-wave Doppler computer. Am J Cardiol 1984: 54(8): 1099–101
- Huntsman LL, Stewart DK, Barnes SR, et al. Noninvasive Doppler determination of cardiac output in man: clinical validation. Circulation 1983: 67(3): 593–602
- Nishimura RA, Callahan MJ, Schaff HV, et al. Noninvasive measurement of cardiac output by continuous-wave Doppler echocardiography: initial experience and review of the literature. Mayo Clin Proc 1984: 59(7): 484–9
- Voyles WF, Greene ER, Miranda IP, et al. Observer variability in serial noninvasive measurements of stroke index using pulsed Doppler flowmetry. Biomed Sci Instrum 1982: 18: 67–75
- Gardin JM, Dabestanl A, Matin K, et al. Reproducibility of Doppler aortic blood flow measurements: studies on intraobserver, interobserver and day-to-day variability in normal subjects. Am J Cardiol 1984: 54(8): 1092–8
- Loeber CP, Goldberg SJ, Allen HD. Doppler echocardiographic comparison of flows distal to the four cardiac valves. J Am Coll Cardiol 1984: 4(2): 268–72
- Fisher DC, Sahn DJ, Friedman MJ, et al. The mitral valve orifice method for noninvasive two-dimensional echo Doppler determinations of cardiac output. Circulation 1983: 67(4): 872–7
- Gardin JM, Burn CS, Childs WJ, et al. Evaluation of blood flow velocity in the ascending aorta and main pulmonary artery of normal subjects by Doppler echocardiography. Am Heart J 1984: 107(2): 310–9
- Waters J, Kwan OL, Kerns G, et al. Limitations of Doppler echocardiography In the calculation of cardiac output. Circulation 1982: 66(2): 122
- Gardin JM, Dabestani A, Rohan MK, et al. Noninvasive studies of ventricular filling with Doppler echocardiography: effects of aging on early and late transmitral flow. J Am Coll Cardiol 1984: 3: 613
- Reed KL, Sahn DJ, Scagnelli S, et al. Diastolic atrio-ventricular valve Doppler flow velocity patterns in human fetuses. J Am Coll Cardiol 1985: 5: 528
- Fisher DC, Voyles WF, Sikes W, et al. Left ventricular filling patterns during ischemia: an echo Doppler study in open chest dogs. J Am Coll Cardiol 1985: 5: 426
- Hatle L, Angelsen B. Pulsed and continuous wave Doppler in diagnosis and assessment of various heart lesions. In: Hatley L. Doppler ultrasound in cardiology: physical principles and clinical practice. 2nd ed. Philadelphia: Lea & Febiger. 1985: 97–204
- Smith M, Dawson P, Elion JL, et al. Systematic correlation of Doppler aortic gradient with specific catheter pressure measurements in experimental aortic stenosis: mean Doppler gradient is optimal. J Am Coll Cardiol 1985: 5: 402
- Ryan T, Armstrong WF, Dillon JC, et al. Doppler evaluation of patients with porcine mitral valves. J Am Coll Cardiol 1985: 5: 526
- Valdes-Cruz LM, Mesel E, Horowitz S, et al. Validation of two-dimensional echo Doppler for calculating pulmonary and systemic flows in a canine model with variable sized ventricular septal defect. Circulation 1983: 68: 597–602
- Barron JV, Sahn DJ, Valdes-Cruz LM, et al. Clinical utility of two-dimensional Doppler echocardiographic techniques for estimating pulmonary to systemic blood flow ratios In children with left to right shunting, atrial septal defect, ventricular septal defect, or patent ductus arteriosus. J Am Coll Cardiol 1984: 3: 169–78
- Levine RA, Stewart WJ, Ascah KJ, et al. How often does Doppler echocardiography provide information otherwise unavailable by imaging studies: experience in 100 patients. J Am Coll Cardiol 1985: 5: 388