REFERENCES
- Hansen AM, Omlandy O, Poulsen OM, Sherson D, Sigsgaard T, Christensen JM, Overgaard E. Correlation between work process-related expo-sure to polycyclic aromatic hydrocarbons and urinary levels of a-naphthol, b-naphthylamine and 1-hydroxypyrene in iron foundry workers. Int Arch Occup Environ Health 1994; 65: 385–94.
- Kraus T, Schramel P, Schaller KH, Zobelein P, Weber A, Angerer J. Exposure assessment in the hard metal manufacturing industry with special regard to tungsten and its compounds. Occup Environ Med 2001; 58: 631–4.
- European Cooperation for Accreditation, EURACHEM. EA-4/05 Accreditation for Chemical Laboratories 1993; 1–34.
- ISO 5725–2 Accuracy (trueness and precision) of measurement methods and results. Part 2: Basic methods for the determination of repeatability and reproducibility of a standard measurement method. Int Organizat Standard 1994; 1–42.
- Bartels H, Bohmer M. Eine mikrometode zur kreatinin bestimmung. Clin Chim Acta 1971; 32: 81–5.
- Christensen JM, Poulsen OM, Anglov T. Method evaluation, quality control, and external quality assurance systems of analytical procedures. In: Seiler HG, Sigel A, Sigel H, editors. Handbook on metals in clinical and analytical chemistry. New York: Marcel Dekker, Inc.; 1994. p. 45–61.
- Christensen JM, Poulsen OM, Anglov T. Protocol for the design and interpretation of method evaluation in atomic absorption spectrometric analysis. Application to the determination of lead and manganese in blood. J Anal Atomic Spectrometry 1992; 7: 329–33.
- Christensen JM, Olsen E, Kristiansen J. AMIQAS PC-Program. Method evaluation quality control profiency testing. Copenhagen, Denmark: National Institute of Occupational Health; 1998.
- Fraser CG, Petersen PH, Libeer JC, Ricos C. Proposals for setting generally applicable quality goals solely based on biology. Ann Clin Biochem 1997; 34: 8–12.
- Sebastian-Gambaro MA, Liron-Hernandez FJ, Fuentes-Arderiu X. Intra- and inter-individual biological variability data bank. Eur J Clin Chem Clin Biochem 1997; 35: 845–52.
- Berg KJ, Kristoffersen DT, Djoseland O, Hartmann A, Breistein E, Lund KK, Narverud J, Nossen JO, Stenstrom J. Reference range of some enzymes and proteins in untimed overnight urine and their stability after freezing. Clin Chim Acta 1998; 272: 225–30.
- Schultz CJ, Dalton RN, Turner C, Neil HAW, Dunger DB. Freezing method affects the concen-tration and variability of urine proteins and the interpretation of data on microalbuminuria. Diabet Med 2000; 17: 7–14.
- Schneider U, Schober EA, Streich NA, Breusch SJ. Urinary creatinine instability falsely increases the deoxypyridinoline/creatinine quotient. Clin Chim Acta 2002; 324: 81–88.