References
- Feldman H. A., Longcope C., Derby C. A., Johannes C. B., Araujo A. B., Coviello A. D., et al. Age trends in the level of serum testosterone and other hormones in middle‐aged men: longitudinal results from the Massachusetts male aging study. J Clin Endocrinol Metab 2002; 87: 589–98
- Jänne O., Apter D., Vihko R. Assay of testosterone, progesterone and 17‐α‐hydroxyprogesterone in human plasma by radioimmunoassay after separation on hydroxyalkoxypropyl Sephadex. J Steroid Biochem 1974; 5: 155–62
- Apter D., Jänne O., Karvonen P., Vihko R. Simultaneous determination of five sex hormones in human serum by radioimmunoassay after chromatography on Lipidex‐5000. Clin Chem 1976; 22: 32–8
- Herold D. A., Fitzgerald R. L. Immunoassays for testosterone in women: better than a guess?. Clin Chem 2003; 49: 1250–1
- Taieb J., Mathian B., Millot F., Patricot M‐C., Mathieu E., Queyrel N., et al. Testosterone measured by 10 immunoassays and by isotope‐dilution gas chromatography‐mass spectrometry in sera from 116 men, women and children. Clin Chem 2003; 49: 1381–95
- Wang C., Catlin D. H., Demers L. M., Starcevic B., Swerdloff R. S. Measurement of total serum testosterone in adult men: comparison of current laboratory methods versus liquid chromatography‐tandem mass spectrometry. J Clin Endocrinol Metab 2004; 89: 534–43
- Boots L. R., Potter S., Downing Potter H., Azziz R. Measurement of total serum testosterone levels using commercially available kits: high degree of between‐kit variability. Fertil Steril 1998; 69: 286–92
- Ismail A. A. A., Walker P. L., Cawood M. L., Barth J. H. Interference in immunoassay is an underestimated problem. Ann Clin Biochem 2002; 39: 366–73
- Cawood M. L., Field H. P., Ford C. G., Gillingwater S., Kickman A., Cowan D., et al. Testosterone measurement by isotope‐dilution liquid chromatography‐tandem mass spectrometry: validation of a method for routine clinical practice. Clin Chem 2005; 51: 1472–9
- Siekmann L. Determination of steroid hormones by the use of isotope dilution‐mass spectrometry: a definitive method in clinical chemistry. J Steroid Biochem 1979; 11: 117–23
- Guide to the expression of uncertainty in measurement. ISO, Geneva 1995
- Linko S., Örnemark U., Kessel R., Taylor P. D. P. Evaluation on uncertainty of measurement in routine clinical chemistry. Applications to determination of substance concentration of calcium and glucose in serum. Clin Chem Lab Med 2002; 40: 391–8
- Rustad P., Felding P., Franzson L., Kairisto V., Lahti A., Mårtensson A., et al. The Nordic Reference Interval Project 2000: recommended reference intervals for 25 common biochemical properties. Scand J Clin Lab Invest 2004; 64: 271–84
- Felding P., Rustad P., Mårtensson A., Kairisto V., Franzson L., Hyltoft Petersen P., et al. Reference individuals, blood collection, treatment of samples and descriptive data from the questionnaire in the Nordic Reference Interval Project 2000. Scand J Clin Lab Invest 2004; 64: 327–42
- Matsumoto A. M., Bremner W. J. Editorial: Serum testosterone assays – accuracy matters. J Clin Endocrinol Metab 2004; 89: 520–4
- Kushnir M. M., Rockwood A. L., Roberts W. L., Pattison E. G., Bunker A. M., Fitzgerald R. L., et al. Performance characteristics of a novel tandem mass spectrometry assay for serum testosterone. Clin Chem 2006; 52: 120–8
- Mohr B. A., Guay A. T., O'Donnell A. B., McKinlay J. B. Normal, bound and nonbound testosterone levels in normally ageing men: results from the Massachusetts male ageing study. Clin Endocrinol 2005; 62: 64–73