References
- Miedema K. Standardization of HbA1c and optimal range of monitoring. Scand J Clin Lab Invest 2005;65:61–72.
- Nathan DM, Kuenen J, Borg R, Zheng H, Schoenfeld D, Heine RJ. Translating the A1C assay into estimated average glucose values. Diabetes Care 2008;31:1473–8.
- Use of glycated haemoglobin (HbA1c) in the diagnosis of diabetes mellitus Abbreviated report of a WHO consultation. Available from: http://www.who.int/diabetes/publications/diagnosis_diabetes2011/en/ [last accessed Dec 2016].
- List of NGSP Certified Methods. Available from: http://www.ngsp.org/certified.asp [last accessed Dec 2016].
- Jaisson S, Leroy N, Meurice J, Guillard E, Gillery P. First evaluation of Capillarys 2 Flex Piercing(R) (Sebia) as a new analyzer for HbA1c assay by capillary electrophoresis. Clin Chem Lab Med 2012;50:1769–75.
- Weykamp C, Waenink-Wieggers H, Kemna E, Siebelder C. HbA1c: performance of the Sebia Capillarys 2 Flex Piercing. Clin Chem Lab Med 2013;51:e129–31.
- Marinova M, Altinier S, Caldini A, Passerini G, Pizzagalli G, Brogi M, Zaninotto M, Ceriotti F, Plebani M. Multicenter evaluation of hemoglobin A1c assay on capillary electrophoresis. Clin Chim Acta 2013;424:207–11.
- Rollborn N, Akerfeldt T, Nordin G, Xu XY, Mandic-Havelka A, Hansson LO, Larsson A. Analysis of HbA1c on an automated multicapillary zone electrophoresis system. Scand J Clin Lab Invest 2017;77:15–18.
- Sebia. Capillarys Hb A1c Using the Capillarys 2 flex-piercing instrument. Available from: http://www.ilexmedical.com/files/Sebia%20inserts/CAPILLARYS_Hb_A1c.pdf [last accessed 29 Dec 2016].
- Little RR, Rohlfing CL, Sacks DB. Status of hemoglobin A1c measurement and goals for improvement: from chaos to order for improving diabetes care. Clin Chem 2011;57:205–14.
- Letter from NKK (Norwegian Clinical Chemistry EQA Program) 29th of February, 2012; 2012.
- NGSP. HbA1c Assay Interferences. Available from: http://www.ngsp.org/interf.asp [last accessed Dec 2016].
- HbVar: A Database of Human Hemoglobin Variants and Thalassemias. Available from: http://globin.bx.psu.edu/hbvar/menu.html [last accessed Dec 2016].
- Chen D, Crimmins DL, Hsu FF, Lindberg FP, Scott MG. Hemoglobin Raleigh as the cause of a falsely increased hemoglobin A1C in an automated ion-exchange HPLC method. Clin Chem 1998;44:1296–301.
- Moo-Penn WF, Bechtel KC, Schmidt RM, Johnson MH, Jue DL, Schmidt DE, Jr., Dunlap WM, Opella SJ, Bonaventura J, Bonaventura C. Hemoglobin Raleigh (beta1 valine replaced by acetylalanine). Structural and functional characterization. Biochemistry 1977;16:4872–9.
- Jain N, Kesimer M, Hoyer JD, Calikoglu AS. Hemoglobin Raleigh results in factitiously low hemoglobin A1c when evaluated via immunoassay analyzer. J Diabetes Complications 2011;25:14–18.