995
Views
30
CrossRef citations to date
0
Altmetric
Review Article

Age-adjusted D-dimer cut-off in the diagnostic strategy for deep vein thrombosis: a systematic review

&
Pages 568-573 | Received 27 Dec 2016, Accepted 06 Oct 2017, Published online: 18 Oct 2017

References

  • Wells PS, Anderson DR, Rodger M, Forgie M, Kearon C, Dreyer J, Kovacs G, Mitchell M, Lewandowski B, Kovacs MJ. Evaluation of d-dimer in the diagnosis of suspected deep-vein thrombosis. N Engl J Med 2003;349:1227–35.
  • Hendriksen JM, Geersing GJ, Lucassen WA, Erkens PM, Stoffers HE, van Weert HC, Büller HR, Hoes AW, Moons KG. Diagnostic prediction models for suspected pulmonary embolism: systematic review and independent external validation in primary care. BMJ 2015;351:h4438.
  • Konstantinides SV, Torbicki A, Agnelli G, Danchin N, Fitzmaurice D, Galiè N, Gibbs JS, Huisman MV, Humbert M, Kucher N, Lang I, Lankeit M, Lekakis J, Maack C, Mayer E, Meneveau N, Perrier A, Pruszczyk P, Rasmussen LH, Schindler TH, Svitil P, Vonk Noordegraaf A, Zamorano JL, Zompatori M. Task Force for the Diagnosis and Management of Acute Pulmonary Embolism of the European Society of Cardiology (ESC). 2014 ESC guidelines on the diagnosis and management of acute pulmonary embolism. Eur Heart J 2014;35:3033–69.
  • Righini M, Perrier A, De Moerloose P, Bounameaux H. D-dimer for venous thromboembolism diagnosis: 20 years later. J Thromb Haemost 2008;6:1059–71.
  • Anoop P, Chappell P, Kulkarni S, Shirley JA. Evaluation of an immunoturbidimetric D-dimer assay and pre-test probability score for suspected venous thromboembolism in a district hospital setting. Hematology 2009;14:305–10.
  • Douma RA, Le Gal G, Söhne M, Righini M, Kamphuisen PW, Perrier A, Kruip MJ, Bounameaux H, Büller HR, Roy PM. Potential of an age adjusted D-dimer cut-off value to improve the exclusion of pulmonary embolism in older patients: a retrospective analysis of three large cohorts. BMJ 2010;340:c1475.
  • Schouten HJ, Geersing GJ, Koek HL, Zuithoff NP, Janssen KJ, Douma RA, van Delden JJ, Moons KG, Reitsma JB. Diagnostic accuracy of conventional or age adjusted D-dimer cut-off values in older patients with suspected venous thromboembolism: systematic review and meta-analysis. BMJ 2013;346:f2492.
  • Righini M, Van Es J, Den Exter PL, Roy PM, Verschuren F, Ghuysen A, Rutschmann OT, Sanchez O, Jaffrelot M, Trinh-Duc A, Le Gall C, Moustafa F, Principe A, Van Houten AA, Ten Wolde M, Douma RA, Hazelaar G, Erkens PM, Van Kralingen KW, Grootenboers MJ, Durian MF, Cheung YW, Meyer G, Bounameaux H, Huisman MV, Kamphuisen PW, Le Gal G. Age-adjusted D-dimer cutoff levels to rule out pulmonary embolism: the ADJUST-PE study. JAMA 2014;311:1117–24.
  • Cini M, Legnani C, Frascaro M, Sartori M, Cosmi B, Palareti G. D-dimer use for deep venous thrombosis exclusion in elderly patients: a comparative analysis of three different approaches to establish cut-off values for an assay with results expressed in D-dimer units. Int J Lab Hematol 2014;36:541–7.
  • Crawford F, Andras A, Welch K, Sheares K, Keeling D, Chappell FM. D-dimer test for excluding the diagnosis of pulmonary embolism. Cochrane Database Syst Rev 2016;8:CD010864.
  • van Es N, van der Hulle T, van Es J, den Exter PL, Douma RA, Goekoop RJ, Mos IC, Galipienzo J, Kamphuisen PW, Huisman MV, Klok FA, Büller HR, Bossuyt PM. Wells rule and d-Dimer testing to rule out pulmonary embolism: A systematic review and individual-patient data meta-analysis. Ann Intern Med 2016;165:253–61.
  • Giannitsis E, Mair J, Christersson C, Siegbahn A, Huber K, Jaffe AS, Peacock WF, Plebani M, Thygesen K, Möckel M, Mueller C, Lindahl B. Biomarker Study Group of the European Society of Cardiology (ESC) Acute Cardiovascular Care Association (ACCA). How to use D-dimer in acute cardiovascular care. Eur Heart J Acute Cardiovasc Care 2017;6:69–80.
  • Raja AS, Greenberg JO, Qaseem A, Denberg TD, Fitterman N, Schuur JD. Clinical Guidelines Committee of the American College of Physicians. Evaluation of patients with suspected acute pulmonary embolism: Best practice advice from the Clinical Guidelines Committee of the American College of Physicians. Ann Intern Med 2015;163:701–11.
  • Moher D, Liberati A, Tetzlaff J, Altman DG. PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med 2009;6:e1000097.
  • Douma RA, Tan M, Schutgens RE, Bates SM, Perrier A, Legnani C, Biesma DH, Ginsberg JS, Bounameaux H, Palareti G, Carrier M, Mol GC, Le Gal G, Kamphuisen PW, Righini M. Using an age-dependent D-dimer cut-off value increases the number of older patients in whom deep vein thrombosis can be safely excluded. Haematologica 2012;97:1507–13.
  • Hamblin AD, Cairns K, Keeling DM. The use of age-dependent D-dimer cut-off values to exclude deep vein thrombosis. Haematologica 2012;97:e43–4.
  • Mullier F, Vanpee D, Jamart J, Dubuc E, Bailly N, Douxfils J, Chatelain C, Dogné JM, Chatelain B. Comparison of five D-dimer reagents and application of an age-adjusted cut-off for the diagnosis of venous thromboembolism in emergency department. Blood Coagul Fibrinolysis 2014;25:309–15.
  • Han C, Zhao Y, Cheng W, Yang J, Yuan J, Zheng Y, Yu X, Zhu T. The performance of age-adjusted D-dimer cut-off in Chinese outpatients with suspected venous thromboembolism. Thromb Res 2015;136:739–43.
  • Broen K, Scholtes B, Vossen R. Predicting the need for further thrombosis diagnostics in suspected DVT is increased by using age adjusted D-dimer values. Thromb Res 2016;145:107–8.
  • Kassim NA, Farid TM, Pessar SA, Shawkat SA. Performance Evaluation of Different d-Dimer Cutoffs in Bedridden Hospitalized Elderly Patients. Clin Appl Thromb Hemost 2017;23:998–1004.
  • Takach Lapner S, Julian JA, Linkins LA, Bates SM, Kearon C. Questioning the use of an age-adjusted D-dimer threshold to exclude venous thromboembolism: analysis of individual patient data from two diagnostic studies. J Thromb Haemost 2016;14:1953–9.
  • Righini M, Goehring C, Bounameaux H, Perrier A. Effects of age on the performance of common diagnostic tests for pulmonary embolism. Am J Med 2000;109:357–61.
  • Robier C, Edler E, Klescher D, Neubauer M. False-positive D-dimer result in a latex-enhanced immunoassay caused by interfering human anti-mouse antibodies. Clin Chem Lab Med 2014;52:e253–5.
  • Dempfle CE. Validation, calibration, and specificity of quantitative D-dimer assays. Semin Vasc Med 2005;5:315–20.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below: