738
Views
0
CrossRef citations to date
0
Altmetric
Research Articles

Analysis of HbA1c using microfluidic card (Capitainer qDBS card) as a pre-step before determination of the HbA1c value with an immunological method

, ORCID Icon &
Pages 11-15 | Received 10 Jul 2023, Accepted 01 Jan 2024, Published online: 19 Jan 2024

References

  • Lind M, Svensson AM, Kosiborod M, et al. Glycemic control and excess mortality in type 1 diabetes. N Engl J Med. 2014;371(21):1972–1982. doi:10.1056/NEJMoa1408214.
  • Eeg-Olofsson K, Cederholm J, Nilsson PM, et al. New aspects of HbA1c as a risk factor for cardiovascular diseases in type 2 diabetes: an observational study from the swedish national diabetes register (NDR). J Intern Med. 2010;268(5):471–482. doi:10.1111/j.1365-2796.2010.02265.x.
  • Paprott R, Schaffrath Rosario A, Busch MA, et al. Association between haemoglobin A1c and all-cause mortality: results of the mortality follow-up of the german national health interview and examination survey 1998. Diabetes Care. 2015;38(2):249–256. doi:10.2337/dc14-1787.
  • Weykamp C. HbA1c: a review of analytical and clinical aspects. Ann Lab Med. 2013;33(6):393–400. doi:10.3343/alm.2013.33.6.393.
  • Weykamp C, John WG, Mosca A. A review of the challenge in measuring hemoglobin A1c. J Diabetes Sci Technol. 2009;3(3):439–445. doi:10.1177/193229680900300306.
  • Colley J, Dambha-Miller H, Stuart B, et al. Home monitoring of haemoglobin A1c in diabetes: a systematic review and narrative synthesis on accuracy, reliability and patient acceptability. Diabet Med. 2023;40(4):e15033. doi:10.1111/dme.15033.
  • Rollborn N, Åkerfeldt T, Nordin G, et al. Analysis of HbA1c on an automated multicapillary zone electrophoresis system. Scand J Clin Lab Invest. 2017;77(1):15–18. doi:10.1080/00365513.2016.1238507.
  • Rollborn N, Nordin G, Mandic-Havelka A, et al. Good agreement Between Hba1c analyzed using capillary electrophoresis, HPLC, immunological and enzymatic methods. JDMC. 2019;1:1–7.
  • Method sheet. Tina-quant hemoglobin A1c gen. 3. Roche Diagnostics 2018-02, v.7. 2018.
  • Läkemedelsbehandling för glukoskontroll vid typ 2-diabetes – behandlingsrekommendation. Information från. Läkemedelsverket. 2017;28(4):29–48.
  • Fokkema MR, Bakker AJ, de Boer F, et al. HbA1c measurements from dried blood spots: validation and patient satisfaction. Clin Chem Lab Med. 2009;47(10):1259–1264. doi:10.1515/CCLM.2009.274.
  • Verougstraete N, Stove V, Stove CP. Remote HbA1c testing via microsampling: fit for purpose? Clin Chem Lab Med. 2023;62(1):3–17. in press doi:10.1515/cclm-2023-0228.
  • Jeppsson JO, Jerntorp P, Almër LO, et al. Capillary blood on filter paper for determination of HbA1c by ion exchange chromatography. Diabetes Care. 1996;19(2):142–145. doi:10.2337/diacare.19.2.142.
  • Carling RS, Emmett EC, Moat SJ. Evaluation of volumetric blood collection devices for the measurement of phenylalanine and tyrosine to monitor patients with phenylketonuria. Clin Chim Acta. 2022;535:157–166. doi:10.1016/j.cca.2023.117744.
  • Jones TG, Warber KD, Roberts BD. Analysis of hemoglobin A1c from dried blood spot samples with the tina-quant® II immunoturbidimetric method. J Diabetes Sci Technol. 2010;4(2):244–249. doi:10.1177/193229681000400203.
  • Nordin G. Kvalitetsmål för HbA1c-metoder som används för diagnostik av typ 2 diabetes, Equalis. https://www.equalis.se/media/m0ja141g/s006_kvalitetsm%C3%A5l-f%C3%B6r-hba1c_2-1.pdf
  • Nathan DM, Krause-Steinrauf H, Braffett BH, et al. Comparison of Central laboratory HbA1c measurements obtained from a capillary collection versus a standard venous whole blood collection in the GRADE and EDIC studies. PLoS ONE. 2021;16(11):e0257154. doi:10.1371/journal.pone.0257154.