References
- Lever JV, Trott PA, Webb AJ. Fine needle aspiration cytology. J Clin Pathol 1985; 38: 1–11
- Mair S, Dunbar F, Becker PJ, Du Plessis W. Fine needle cytology: is aspiration suction necessary? A study of 100 masses in various sites. Acta Cytol 1989; 33: 809–13
- Kumarasinghe MP, Sheriffdeen AH. Fine needle sampling without aspiration. Pathology 1995; 27: 330–2
- Bhutani MS, Suryaprasad S, Moezzi J, Seabrook D. Improved technique for performing endoscopic ultrasound guided fine needle aspiration of lymph nodes. Endoscopy 1999; 31: 550–3
- Wallace MB, Kennedy T, Durkalski V, Eloubeidi MA, Etamad R, Matsuda K, et al. Randomized controlled trial of EUS-guided fine needle aspiration techniques for the detection of malignant lymphadenopathy. Gastrointest Endosc 2001; 54: 441–7
- Larghi A, Noffsinger A, Dye CE, Hart J, Waxman I. EUS-guided fine needle tissue acquisition by using high negative pressure suction for the evaluation of solid masses: a pilot study. Gastrointest Endosc 2005; 62: 768–74
- Knuth DE. The art of computer programming volume 2: seminumerical algorithms3rd ed. Addison-Wesley Professional, Boston 1997
- Cohen J. Power primer. Psychol Bull 1992; 112: 155–9
- Kate MS, Kamal MM, Bobhate SK, Kher AV. Evaluation of fine needle capillary sampling in superficial and deep-seated lesions. An analysis of 670 cases. Acta Cytol 1998; 42: 679–84
- Kinney TB, Lee MJ, Filomena CA, Krebs TL, Dawson SL, Smith PL, et al. Fine-needle biopsy: prospective comparison of aspiration versus nonaspiration techniques in the abdomen. Radiology 1993; 186: 549–52
- Dey P, Ray R. Comparison of fine needle sampling by capillary action and fine needle aspiration. Cytopathology 1993; 4: 299–303
- Akhtar SS, Imran-Ul-Huq S, Faiz-U-Din M, Reyes LM. Efficacy of fine-needle capillary biopsy in the assessment of patients with superficial lymphadenopathy. Cancer 1997; 81: 277–80
- Vetrani A, Fulciniti F, Di Benedetto G, Zeppa P, Troncone G, Boscaino A, et al. Fine-needle aspiration biopsies of breast masses. An additional experience with 1153 cases (1985 to 1988) and a meta-analysis. Cancer 1992; 69: 736–40
- Pothier DD, Narula AA. Should we apply suction during fine needle cytology of thyroid lesions? A systematic review and meta-analysis. Ann R Coll Surg Engl 2006; 88: 643–5
- Vilmann P, Hancke S, Henriksen FW, Jacobsen GK. Endoscopic ultrasonography with guided fine needle aspiration biopsy in pancreatic disease. A new diagnostic procedure. Gastrointest Endosc 1992; 38: 172–3
- Mortensen MB, Pless T, Durup J, Ainsworth AP, Plagborg GJ, Hovendal C. Clinical impact of endoscopic ultrasound-guided fine needle aspiration biopsy in patients with upper gastrointestinal tract malignancies. A prospective study. Endoscopy 2001; 33: 537–40
- Shah JN, Ahmad NA, Beilstein MC, Ginsberg GG, Kochman ML. Clinical impact of endoscopic ultrasonography on the management of malignancies. Clin Gastroenterol Hepatol 2004; 2: 1069–73
- Chang KJ. Maximizing the yield of EUS-guided fine-needle aspiration. Gastrointest Endosc 2002; 56: S28–34
- Vilmann P, Saftoiu A. Endoscopic ultrasound-guided fine needle aspiration biopsy: equipment and technique. J Gastroenterol Hepatol 2006; 21: 1646–55
- Storch IM, Sussman DA, Jorda M, Ribeiro A. Evaluation of fine needle aspiration vs. fine needle capillary sampling on specimen quality and diagnostic accuracy in endoscopic ultrasound-guided biopsy. Acta Cytol 2007; 51: 837–42
- Erickson RA, Sayage-Rabie L, Beissner RS. Factors predicting the number of EUS-guided fine-needle passes for the diagnosis of pancreatic malignancies. Gastrointest Endosc 2000; 51: 184–90
- LeBlanc JK, Ciaccia D, Al-Assi MT, McGrath K, Imperiale T, Tao LC, et al. Optimal number of EUS-guided fine-needle passes needed to obtain a correct diagnosis. Gastrointest Endosc 2004; 59: 475–81