References
- Gardner RM. Practical crime scene processing and investigation. 2nd ed. Boca Raton (FL): CRC Press; 2012.
- Barni F, Lewis A, Miskelly GM, Lago GM. Forensic application of luminol reaction as a presumptive test for latent blood detection. Talanta. 2007;72:896–913.
- Bodziak WJ. Use of leucocrystal violet to enhance shoe prints in blood. Forensic Sci Int. 1996;82:45–52. doi:https://doi.org/10.1016/0379-0738(96)01965-2.
- Farrugia KJ, Savage KA, Bandey H, Ciuksza T, Daeid NN. Chemical enhancement of footwear impressions in blood on fabric — Part 2: peroxidase reagents. Sci Just. 2011;51:110–121. doi:https://doi.org/10.1016/j.scijus.2010.11.002.
- Grodsky M, Wright K, Kirk P. Simplified preliminary blood testing – an improved technique and a comparative study of methods. J Crim Law Criminol. 1951;42:95–104. doi:https://doi.org/10.2307/1140307.
- DeHaan DJ, Clark JD, Spear TF, Oswalt R, Barney SS Chemical enhancement of fingerprints in blood: an evaluation of methods, effects on DNA and assessment of chemical hazards. 2011. Available from: www.latent-prints.com/cac_blood.html (Accessed 12/6/2020).
- Zweidinger R, Lytle LT, Pitt CG. Photography of bloodstains visualised by luminol. J Forensic Sci. 1973;18:296–302. doi:https://doi.org/10.1520/JFS10031J.
- Polacco S, Wilson P, Illes M, Stotesbury T. Quantifying chemiluminescence of the forensic luminol test for ovine blood in a dilution and time series. Forensic Sci Int. 2018;290:36–41. doi:https://doi.org/10.1016/j.forsciint.2018.06.026.
- Tobe SS, Watson N, Daeid NN. Evaluation of six presumptive tests for blood, their specificity, sensitivity, and effect on high molecular-weight DNA. J Forensic Sci. 2007;52:102–109. doi:https://doi.org/10.1111/j.1556-4029.2006.00324.x.
- Barni F, Lewis SW, Berti A, Miskelly GM, Lago G. Forensic application of the luminol reaction as a presumptive test for latent blood detection. Talanta. 2007;72:896–913.
- Swander CJ, Stites JG Evaluation of the ABAcard® Hematrace® for the forensic identification of human blood. Paper submitted to the Michigan Association of Forensic Science Annual Meeting, Michigan (USA); 1998.
- Horjan I, Barbaric L, Mrsic G. Applicability of three commercially available kits for forensic identification of blood stains. J Forensic Legal Med. 2016;38:101–105. doi:https://doi.org/10.1016/j.jflm.2015.11.021.
- Abacus Diagnostics, Inc. ABAcard® Hematrace® for the forensic identification of human blood at crime scenes. Technical Information Sheet, viewed 1 February 2016.
- Schweers BA, Old J, Boonlayangoor PW, Reich K. Development validation of a novel lateral flow strip test for rapid identification of human blood, Rapid stain identification-Blood, RSIDTM-Blood. Forensic Sci Int Gen. 2008;2:243–247. doi:https://doi.org/10.1016/j.fsigen.2007.12.006.
- Rosalia R Validation studies of a novel lateral flow strip test for rapid stain identification of bodily fluids at local conditions: from laboratory testing to non-destructive rapid confirmatory identification at a crime scene [Master’s thesis]. Amsterdam (The Netherlands): University of Amsterdam; 2010.
- Nicloux C, Bressler J. Effect of four latent blood visualization products on DNA. J Bloodstain Pattern Analysis. 2014;30:3–11.
- Turrina S, Filipponi G, Atzer R, Zaglia E, De Leo D. Validation studies of rapid stain identification-blood (RSID-blood) kit in forensic caseworks. Forensic Sci Int Gen Suppl Ser. 2008;1:74–75.
- Stewart V, Deacon P, Zahra N, Uchimoto ML, Farrugia KJ. The effect of mark enhancement techniques on the presumptive and confirmatory tests for blood. Sci Just. 2018;58:386–396. doi:https://doi.org/10.1016/j.scijus.2018.06.007.
- Brown LD, Cat TT, DasGupta A. Interval estimation for a proportion. Statistical Sci. 2001;16:101–133. doi:https://doi.org/10.1214/ss/1009213286.
- Sergeant ESG. (2016) Epitools epidemiological calculators. AusVet Pty Ltd. Available from: http://epitools.ausvet.com.au. (Accessed 12/6/2020).
- R Core Team. 2018 R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna (Austria). Available from: https://www.R-project.org. (Accessed 12/6/2020).
- Tate J, Ward G. Interferences in Immunoassay. Clinical Biochem Rev. 2004;25:105–120.
- Stolk LM, Scheijen JL. Urine adulteration with denture-cleaning tablets. J Analytical Toxicol. 1997;21:403. doi:https://doi.org/10.1093/jat/21.5.403.
- Hochmeister MN, Budowle B, Sparkes R, Rudin O, Gehrig C, Thali M, Schmidt L, Cordier A, Dirnhofer R. Validation studies of an immunochromatographic 1-step test for the forensic identification of human blood. J Forensic Sci. 1999;44:597–602. doi:https://doi.org/10.1520/JFS14516J.
- Fox A, Gittos M, Harbison S, Fleming R, Wivell R. Exploring the recovery and detection of messenger RNA and DNA from enhanced fingermarks in blood. Sci Just. 2014;54:192–198. doi:https://doi.org/10.1016/j.scijus.2014.01.001.