References
- ABE, M., HIRAOKA, M., TAKAHASHI, M., EGAWA, S., MATSUDA, C., ONOYAMA, Y., MORITA, K., KAKEHI, M., and SUGAHARA, T., 1986, Multi-institutional studies on hyperthermia using an 8-MHz radiofrequency capacitive heating device (Thermotron RF-8) in com-bination with radiation for cancer therapy. Cancer, 58, 1589–1595.
- BINI, M., IGNESTI, A., MILLANTA, L., OLMI, R., RUBINO, N., and VANNI, R., 1985, An un-balanced electric applicator for RF hyperthermia. IEEA Transactions on Biomedical Engineering, BME-32, 638–641.
- DE LEEUW, A. A. C., CREZEE, J., and LAGENDIJK, J. J. W., 1993, Temperature and SAR measurements in deep-body hyperthermia with thermocouple thermometry. International Journal of Hyperthermia, 9, 685–697.
- HIRAKI, Y., NAKAJO, M., TAKESHITA, T., and CHUREI, H., 2000, Change of the SAR and thermal distributions of the RF capacitive intracavitary hyperthermia with the position of the opposite flat applicator. International Journal of Hyperthermia, in press.
- KATO, H., 1991, Technology of RF capacitive heating. Japanese Journal of Hyperthermic Oncology, 7, 1–22.
- KATO,H., and ISHIDA, T., 1993, Present and future status of noninvasive selective deep heating using RF in hyperthermia Medical & Biological Engineering & Computing, Kyoto World Congress supplement, 31, S2—S11.
- OVERGAAARD,J.,1978. Biological effect of 27.12 MHz short-wave diathermy heating in experi-mental tumours. IEEA Transactions on Microwave Theory and Techniques, MT[-26, 523–529.
- SONG, C. W., RHEE, J. G., LEE, C. K. K., and LEVITT, S. H., 1986, Capacitive heating of phantom and human tumors with an 8 MHz radiofrequency applicator (Thermotron RF-8). International Journal of Radiation Oncology, Biology and Physics, 12, 365–372.
- TANAKA, H., KATO, H NISHIDA, T., KANO, E., SUGAHARA, T., and ISHIDA, T., 1981, Physical basis of RF hyperthermia for cancer therapy (2) Measurement of distribution of absorbed power from radiofrequency exposure in agar phantom. Journal of Radiation Research, 22, 101–108.
- TREMBLY, B. S.,1985, The effects of driving frequency and antenna length on power deposition within a microwave antenna array used for hyperthermia. IEEA Transactions on Biomedical Engineering, BME-32, 152–157.
- VISSER, A. G., and VAN RHOON, G. C., 1995, Technical and clinical quality assurance. Thermoradiotherapy and thermochemotherapy, Vol. 1. Biology, Physiology and Physics, edited by M. H. Seegenschmiedt, P. Fessenden and C. C. Vernon (Berlin: Springer), pp. 453–472.
- VRBA, J., FRANCONI, C and LAPES, M ., 1996, Theoretical limits for the penetration depth of intracavitary applicators. International Journal of Hyperthermia, 12, 737–742.