Image accuracy improvements in microwave tomographic thermometry: phantom experience

, , , &
Pages 534-550 | Published online: 09 Jul 2009

  • Van der Zee J, Gonzalez DG, van Rhoon GC, van Dijk JDP, van Putten WLJ, Hart AAM. Comparison of radiotherapy alone with radiotherapy plus hyperthermia in locally advanced pelvic tumors: a prospective, randomised multicentre trial. Lancet 2000; 355: 1119-25.
  • Overgaard J, Gonzalez-Gonzales D, Hulshof MCCM, Arcangeli G, Dahl O, Mella O, Bentzen SM. Randomized trial of hyperthermia as adjuvant to radiotherapy for recurrent or metastatic malignant melanoma. Lancet 1995; 345: 540-3.
  • Paulsen KD. Noninvasive monitoring and assessment of hyperthermia treatments: trends in current technology. In: Moriarty M, Mothersill C, Seymour C, Edington M, Ward JF, Fry RJM, eds. Radiation Research, Volume 2: Proceedings 11th International Congress of Radiation Research, 18-23 July, Dublin, 1999, 841-44, Lawrence, Kansas: Alien Press.
  • Carter DL, MacFall JR, Clegg ST, Wan X, Prescott DM, Charles HC, Samulski TV. Magnetic resonance thermometry during hyperthermia for human high-grade sarcoma. Int J Radiat Oncol Biol Phys 1998; 40: 815-22.
  • MacFall J, Prescott DM, Fullar E, Samulski TV. Temperature dependence of canine brain tissue diffusion coefficient measured in vivo with magnetic resonance echo-planar imaging. Int J Hyperthermia 1995; 11: 73-86.
  • DePorter J, De Wagter C, De Deene Y, Thomsen C, Stahlberg TF, Achten E. The protonresonance-frequency-shift method compared with molecular diffusion for quantitative measurement of two-dimensional time dependent temperature distributions in a phantom. J Magn Reson Ser B 1994; 103: 2340-1.
  • Webb AG, Wong M, Niesman M, Kolbeck KJ, Wilmes LJ, Magin RL, Suslick KJ. In-vivo NMR thermometry with liposomes containing Co complexes. Int J Hyperthermia 1995; 11:821-7.
  • Wust P, Konstanczak P, Sander B, Knappe V, Schrunder S, Wlodarczyk W, Frenzel T, Muller G, Felix R. Non-invasive thermometry performed by measuring the chemical shift of a lanthanide complex. In: Franconi C, Arcangeli G, Cavaliere R, eds. Proceedings of the 7th International Congress of Hyperthermic Oncology, 9-13 April, Rome, 1996, II 436-68, Rome: Torvergata Post.
  • McDannold N, King RL, Jolesz FA, Hynynen K. The use of quantitative temperature images to predict the optimal power for focused ultrasound surgery: in vivo verification in rabbit muscle and brain. Med Phys 2002; 29: 356-65.
  • Siep R, Ebbini ES. Noninvasive estimation of tissue temperature response of heating fields using diagnostic ultrasound. IEEE Trans Biomed Eng 1995; 42: 828-39.
  • Siep R, VanBaren P, Cain CA, Ebbini ES. Noninvasive real-time multipoint temperature control for ultrasound phased array treatments. IEEE Trans Ultrason Ferroelec Freq Control 1996; 43: 1063-73.
  • Simon C, VanBaren P, Ebbini ES. Motion compensation algorithm for two-dimensional temperature estimation using diagnostic pulse-echo ultrasound. Surgical Applications of Energy, Proceedings of SPIE, 1998; 3249: 182-92.
  • Chive M. Use of microwave radiometry for hyperthermia monitoring and as a basis for thermal dosimetry. In: Gautherie M, ed. Methods of Hyperthermia Control, Clinical Thermology Series (Thermotherapy). New York: Springer-Verlag, 1990; 113-28.
  • Dubois L, Pribetich J, Fabre J, Chive M, Moschetto Y. Non-invasive microwave multifrequency radiometry used in microwave hyperthermia for bi-dimensional reconstruction of temperature patterns. Int J Hyperthermia 1993; 9: 415-43.
  • Maruyma K, Mizushina S, Sugiura T, Van Leeuwen GMJ, Hand JW, Marrocco G, Bardati F, Edwards AD, Azzopardi D, Land D. Feasibility of noninvasive measurement of deep brain temperature in newborn infants by multifrequency microwave radiometry. IEEE Trans Microwave Theory Techniques 2000; 48: 2141-7.
  • Stauffer PR, Jacobsen S, Neuman D, Rossetto F. Progress toward radiometry controlled conformai microwave array hyperthermia applicator. 22nd Annual EMBS International Conference. Chicago, IL, 2000; 1613-16, Piscataway, NJ: IEEE Publications.
  • Jacobsen S, Stauffer PR, Neuman DG. Dual-mode antenna design for microwave heating and noninvasive thermometry of superficial tissue disease. IEEE Trans Biomed Eng 2000; 47: 1500-9.
  • Bolomey J, Hawley M. Non-invasive control of hyperthermia. In: Gautherie M, ed. Methods of Hyperthermia Control, Clinical Thermology Series (Thermotherapy). New York: Springer-Verlag, 1990; 35-111.
  • Blad B, Persson B, Lindstrom K. Quantitative assessment of impedance tomography for temperature measurements in hyperthermia. Int J Hyperthermia 1992; 8: 33-43.
  • Hawley MS, Conway J, Amasha H, Mangnall YF, Van Rhoon GC. Electrical impedance tomography: prospects for non-invasive control of deep hyperthermia treatments. Frontiers Med Bioll Eng 1992; 4; 119-28.
  • Paulsen KD, Moskowitz MJ, Ryan TP, Mitchell SE, Hoopes PJ. Initial in-vivo experience with EIT as a thermal estimator during hyperthermia. Int J Hyperthermia 1996; 12: 57391.
  • Moskowitz MJ, Paulsen KD, Ryan TP, Pang D. Temperature field estimation using electrical impedance profiling methods: II experimental system description and phantom results. Int J Hyperthermia 1994; 10: 229-45.
  • Moskowitz MJ, Ryan TP, Paulsen KD, Mitchell SE. Clinical implementation of electrical impedance tomography with hyperthermia. Int J Hyperthermia 1995; 11: 141-9.
  • Chang JT, Paulsen KD, Meaney PM, Fanning M. Noninvasive thermal assessment of tissue phantoms using an active near field microwave imaging technique. Int J Hyperthermia 1998; 14: 513-34.
  • Mallorqui JJ, Broquetas A, Jofre L, Cardama A. Noninvasive active microwave thermometry with a microwave tomographic scanner in hyperthermia treatments. In: Fleming AHJ, Joyner KH, eds. ACES Special Issue an Bioelectromagnetic Computations, ACES J 1992; 7: 121-7.
  • Miyakawa M. Tomographic measurement of temperature change in phantoms of the human body by chirp radar-type microwave computed tomography. Med Biol Eng Comput 1993; 31: 531-6.
  • Bertero M, Miyakawa M, Boccacci P, Conte F, Orikasa K, Furutani M. Image restoration in chirp-pulse microwave CT (CP-MCT). IEEE Trans Biomed Eng 2000; 47: 690-9.
  • Duck FA. Physical properties of tissues: a comprehensive reference book. London: Academic Press, 1990.
  • Hasted JB. Aqueous Dielectrics. London: Chapman and Hall, 1972.
  • Von Hippel AR. Dielectric Materials and Applications. New York: The Technology Press of MIT and Wiley & Sons, Inc., 1954.
  • Stogryn A. Equations for calculating the dielectric constant of saline water. IEEE Trans Microwave Theory Techniques 1971; 19: 733-6.
  • Meaney PM, Paulsen KD, Ryan TP. Two-dimensional hybrid element image reconstruction for TM illumination. IEEE Trans Antennas Propagation 1995; 43: 239-47.
  • Meaney PM, Paulsen KD, Chang JT. Near-field microwave imaging of biologically-based materials using a monopole transceiver system. IEEE Trans Microwave Theory Techniques 1998; 46: 31-45.
  • Meaney PM, Demidenko E, Yagnamurthy NK, Li D, Fanning MW, Paulsen KD. A twostage microwave image reconstruction procedure for improved internal feature extraction. Med Phys 2001; 28: 2358-69.
  • Meaney PM, Paulsen KD, Pogue BW, Miga MI. Microwave image reconstruction utilizing log-magnitude and unwrapped phase to improve high-contrast object recovery. IEEE Trans Medlmag 2001; 20: 104-16.
  • Joachimowicz N, Pichot C, Hugonin R. Inverse scattering: an iterative numerical method for electromagnetic imaging. IEEE Trans Antennas Propagation 1991; 39: 1742-52.
  • Meaney PM, Yagnamurthy NK, Paulsen KD. Pre-scaling of reconstruction parameter components to reduce imbalance in image recovery process. Phys Med Biol 2002; 47: 1101-19.
  • Jacobsen S, Stauffer PR. Non-parametric 1-D temperature restoration in lossy media using Tikhonov regularization on sparse radiometry data. IEEE Trans Biomed Eng 2002; 50: 178-88.
  • Kaltenbacher B. Newton-type methods for ill-posed problems. Inverse Problems 1997; 13: 729-53.
  • Marquardt DW. An algorithm for least-squares estimation of non linear parameters. / Soc IndAppl Math 1963; 11: 431-41.
  • McRae DA, Esrick, MA. Deconvolved electrical impedance spectra track distinct cell morphology changes. IEEE Trans Biomed Eng 1996; 43: 607-18.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.