1,981
Views
20
CrossRef citations to date
0
Altmetric
Research Article

Multiple antenna placement in microwave ablation assisted by a three-dimensional fusion image navigation system for hepatocellular carcinoma

ORCID Icon, , , , , ORCID Icon, , , & show all
Pages 122-132 | Received 11 Nov 2017, Accepted 30 May 2018, Published online: 09 Oct 2018

References

  • Shibata T, Iimuro Y, Yamamoto Y, et al. Small hepatocellular carcinoma: comparison of radio-frequency ablation and percutaneous microwave coagulation therapy [Clinical Trial Comparative Study Evaluation Studies Randomized Controlled Trial]. Radiology. 2002;223:331–337.
  • Dong B, Liang P, Yu X, et al. Percutaneous sonographically guided microwave coagulation therapy for hepatocellular carcinoma: results in 234 patients [Evaluation Studies Research Support, Non-U.S. Gov't]. Am J Roentgenol. 2003;180:1547–1555.
  • Wright AS, Lee FT Jr, Mahvi DM. Hepatic microwave ablation with multiple antennae results in synergistically larger zones of coagulation necrosis. Ann Surg Oncol. 2003;10:275–283.
  • Xu HX, Xie XY, Lu MD, et al. Ultrasound-guided percutaneous thermal ablation of hepatocellular carcinoma using microwave and radiofrequency ablation [Evaluation Studies]. Clin Radiol. 2004;59:53–61.
  • Lu MD, Xu HX, Xie XY, et al. Percutaneous microwave and radiofrequency ablation for hepatocellular carcinoma: a retrospective comparative study. J Gastroenterol. 2005;40:1054–1060.
  • Meredith K, Lee F, Henry MB, et al. Microwave ablation of hepatic tumors using dual-loop probes: results of a phase I clinical trial [Clinical Trial, Phase I]. J Gastrointest Surg. 2005;9:1354–1360.
  • Simon CJ, Dupuy DE, Iannitti DA, et al. Intraoperative triple antenna hepatic microwave ablation [Clinical Trial, Phase I Multicenter Study Research Support, Non-U.S. Gov't]. Am J Roentgenol. 2006;187:W333–W340.
  • Martin RC, Scoggins CR, McMasters KM. Microwave hepatic ablation: initial experience of safety and efficacy [Clinical Trial, Phase II Research Support, Non-U.S. Gov't]. J Surg Oncol. 2007;96:481–486.
  • Jagad RB, Koshariya M, Kawamoto J, et al. Laparoscopic microwave ablation of liver tumors: our experience. Hepatogastroenterology. 2008;55:27–32.
  • Liang P, Wang Y. Microwave ablation of hepatocellular carcinoma [Review]. Oncology. 2007;72:124–131. Suppl doi: 10.1159/000111718.
  • Zhang X, Chen B, Hu S, et al. Microwave ablation with cooled-tip electrode for liver cancer: an analysis of 160 cases. Hepatogastroenterology. 2008;55:2184–2187.
  • Liang P, Wang Y, Yu X, et al. Malignant liver tumors: treatment with percutaneous microwave ablation–complications among cohort of 1136 patients. Radiology. 2009;251:933–940.
  • Liang P, Dong B, Yu X, et al. Prognostic factors for survival in patients with hepatocellular carcinoma after percutaneous microwave ablation [Research Support, Non-U.S. Gov't]. Radiology. 2005;235:299–307.
  • Wang ZL, Liang P, Dong BW, et al. Prognostic factors and recurrence of small hepatocellular carcinoma after hepatic resection or microwave ablation: a retrospective study [Comparative Study]. J Gastrointest Surg. 2008;12:327–337.
  • Liu LN, Xu HX, Lu MD, et al. Percutaneous ultrasound-guided thermal ablation for liver tumor with artificial pleural effusion or ascites [Evaluation Studies Research Support, Non-U.S. Gov't]. Chin J Cancer. 2010;29:830–835.
  • Eisele RM, Schumacher G, Lopez HE, et al. Role of B-mode ultrasound screening in detection of local tumor recurrence in the first year after radiofrequency ablation in the liver. Cancer Detect Prev. 2007;31:316–322.
  • Solbiati L, Ierace T, Tonolini M, et al. Guidance and monitoring of radiofrequency liver tumor ablation with contrast-enhanced ultrasound. Eur J Radiol. 2004;51:S19–S23.
  • Xu J, Jia ZZ, Song ZJ, et al. Three-dimensional ultrasound image-guided robotic system for accurate microwave coagulation of malignant liver tumours [Research Support, Non-U.S. Gov't]. Int J Med Robot . 2010;6:256–268.
  • Ward TJ, Goldman RE, Weintraub JL. Electromagnetic navigation with multimodality image fusion for image-guided percutaneous interventions. Tech Vasc Interv Radiol. 2013;16:177–181.
  • Ludwig DR, Menon PG, Schwartzman D. CT-electromagnetic three-dimensional tracking for renal endovascular sympathetic ablation catheter positioning in an animal model [Research Support, Non-U.S. Gov't]. J Vasc Interv Radiol. 2015;26:741–745.
  • Neshat H, Cool DW, Barker K, et al. A 3D ultrasound scanning system for image guided liver interventions [Research Support, Non-U.S. Med Phys. 2013;40:112903.
  • Abi-Jaoudeh N, Kruecker J, Kadoury S, et al. Multimodality image fusion-guided procedures: technique, accuracy, and applications [Review]. Cardiovasc Intervent Radiol. 2012;35:986–998.
  • Ries M, de Senneville BD, Roujol S, et al. Real-time 3D target tracking in MRI guided focused ultrasound ablations in moving tissues [Research Support, Non-U.S. Magn Reson Med. 2010;64:1704–1712.
  • Schmidt EJ, Mallozzi RP, Thiagalingam A, et al. Electroanatomic mapping and radiofrequency ablation of porcine left atria and atrioventricular nodes using magnetic resonance catheter tracking [Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't]. Circ Arrhythm Electrophysiol. 2009;2:695–704.
  • Boctor EM, Choti MA, Burdette EC, et al. Three-dimensional ultrasound-guided robotic needle placement: an experimental evaluation [Research Support, N.I.H., Extramural Research Support, U.S. Gov't, Non-P.H.S.]. Int J Med Robot Comput Assist Surg. 2008;4:180–191.
  • Lu T, Liang P, Wu WB, et al. Integration of the Image-Guided Surgery Toolkit (IGSTK) into the Medical Imaging Interaction Toolkit (MITK). J Digit Imaging. 2012;25:729–737.
  • Liu F, Liang P, Yu X, et al. A three-dimensional visualisation preoperative treatment planning system in microwave ablation for liver cancer: a preliminary clinical application [Clinical Trial Research Support, Non-U.S. Gov't]. Int J Hyperthermia. 2013;29:671–677.
  • Wu W, Xue J, Liang P, et al. The assistant function of three-dimensional information for I125 particle implantation [Research Support, Non-U.S. Gov't.]. IEEE J Biomed Health Inform. 2014;18:77–82.
  • Wu W, Xue Y, Wang D, et al. A simulator for percutaneous hepatic microwave thermal ablation under ultrasound guidance [Research Support, Non-U.S. Gov't]. Int J Hyperthermia. 2014;30:429–437.
  • Wu W, Xue Y, Wang D, et al. Application of 3D imaging in the real-time US-CT fusion navigation for minimal invasive tumor therapy. Int J Comput Assist Radiol Surg. 2015;10(10):1651–1658.
  • Liu F, Yu X, Liang P, et al. Contrast-enhanced ultrasound-guided microwave ablation for hepatocellular carcinoma inconspicuous on conventional ultrasound [Evaluation Studies Research Support, Non-U.S. Gov't]. Group. Int J Hyperthermia. 2011;27:555–562.
  • Qu P, Yu X, Liang P, et al. Contrast-enhanced ultrasound in the characterization of hepatocellular carcinomas treated by ablation: comparison with contrast-enhanced magnetic resonance imaging [Controlled Clinical Trial Research Support, Non-U.S. Gov't]. Ultrasound Med Biol. 2013;39:1571–1579.
  • Ahmed M, Solbiati L, Brace CL, et al. Image-guided tumor ablation: standardization of terminology and reporting criteria–a 10-year update [Consensus Development Conference]. J Vasc Interv Radiol. 2014;25:1691–1705 e4.
  • Dindo D, Demartines N, Clavien PA. Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey [Comparative Study Evaluation Studies Validation Studies]. Ann Surg. 2004;240:205–213.
  • Institute NC. Cancer therapy evaluation program: common toxicity evaluation manual. Version 2.0. 1999.
  • de Lope CR, Tremosini S, Forner A, Reig M, Bruix J. Management of HCC [Research Support, Non-U.S. Gov't Review]. J Hepatol. 2012;56:S75–S87.
  • Kudo M, Izumi N, Kokudo N, et al. Management of hepatocellular carcinoma in Japan: Consensus-Based Clinical Practice Guidelines proposed by the Japan Society of Hepatology (JSH) 2010 updated version [Practice Guideline]. Dig Dis. 2011;29:339–364.
  • Simpfendorfer T, Li Z, Gasch C, et al. Three-Dimensional Reconstruction of Preoperative Imaging Improves Surgical Success in Laparoscopy. J Laparoendosc Adv Surg Tech A. 2017;27:181–185.
  • Seitel A, Engel M, Sommer CM, et al. Computer-assisted trajectory planning for percutaneous needle insertions [Research Support, Non-U.S. Gov't]. Med Phys. 2011;38:3246–3259.
  • Poulou LS, Botsa E, Thanou I, Ziakas PD, Thanos L. Percutaneous microwave ablation vs radiofrequency ablation in the treatment of hepatocellular carcinoma [Review]. World J Hepatol. 2015;7:1054–1063.
  • Muller SA, Maier-Hein L, Mehrabi A, et al. Creation and establishment of a respiratory liver motion simulator for liver interventions [Research Support, Non-U.S. Gov't]. Med Phys. 2007;34:4605–4608.
  • Wagner M, Gondan M, Zollner C, et al. Electromagnetic organ tracking allows for real-time compensation of tissue shift in image-guided laparoscopic rectal surgery: results of a phantom study [Comparative Study Evaluation Studies Research Support, Non-U.S. Gov't]. Surg Endosc. 2016;30:495–503.
  • Tanner C, Zur Y, French K, et al. In vivo validation of spatio-temporal liver motion prediction from motion tracked on MR thermometry images. Int J Comput Assist Radiol Surg. 2016;11:1143–1152.
  • Schwenke M, Strehlow J, Haase S, et al. An integrated model-based software for FUS in moving abdominal organs [Research Support, Non-U.S. Gov't]. Int J Hyperthermia. 2015;31:240–250.