References
- Zervas N, Cosman E, Cosman B. A pressure-balanced radio-telemetry system for the measurement of intracranial pressure. A preliminary design report. J Neurosurg 1977;47:899–911.
- Frischholz M, Sarmento L, Wenzel M, et al. Telemetric implantable pressure sensor for short- and long-term monitoring of intracranial pressure. Proceedings of the 29th Annual International Conference of the IEEE EMBS, Cité Internationale; 2007 Aug 23–26; Lyon, France.
- Wilson M, Milledge J. Direct measurement of intracranial pressure at high altitude and correlation of ventricular size with acute mountain sickness: Brian Cummins' results from the 1985 Kishtwar expedition. Neurosurgery 2008;63:970–5.
- Chapman P, Cosman E, Arnold M. Telemetric ICP monitoring after surgery for posterior fossa and third ventricular tumors. Technical note. J Neurosurg 1984;60:649–51.
- Welschold S, Schmalhausen E, Dodier P, et al. First clinical results with a new telemetric intracranial pressure-monitoring system. Neurosurgery 2012;70:44–49.
- Lilja A, Andresen M, Hadi A, et al. Clinical experience with telemetric intracranial pressure monitoring in a Danish neurosurgical centre. Clin Neurol Neurosurg 2014;120:36–40.
- Antes S, Tschan C, Kunze G, et al. Clinical and radiological findings in long-term intracranial pressure monitoring. Acta Neurochir 2014;156:1009–19.
- Magnéli S, Howells T, Saiepour D, et al. Telemetric intracranial pressure monitoring: a noninvasive method to follow-up children with complex craniosynostoses. Childs Nerv Syst 2016;32:1311–5.
- Schmitt M, Kiefer M, Antes S, Eymann R. Detection of hidden pseudotumour cerebri behind chiari 1 malformation: value of telemetric ICP monitoring. Childs Nerv Syst 2012;28:1811–13.
- Andresen M, Hadi A, Petersen L, Juhler M. Effect of postural changes on ICP in healthy and ill subjects. Acta Neurochir (Wien) 2015;157:109–13.
- Freimann FB, Schulz M, Haberl H, Thomale U-W. Feasibility of telemetric ICP-guided valve adjustments for complex shunt therapy. Childs Nerv Syst 2014;30:689–97.
- Antes S, Tschan CA, Oertel JM. An operative technique combining endoscopic third ventriculostomy and long-term ICP monitoring. Childs Nerv Syst 2014;30:331–5.
- Kiefer M, Antes S, Schmitt M, et al. Long-term performance of a CE-approved telemetric intracranial pressure monitoring. Proceedings of the 33rd Annual International Conference of the IEEE EMBS; 2011 Aug 30–Sep 3; Boston, Massachusetts USA.
- Freimann FB, Sprung C, Chopra SS, et al. Large-scale referencing of the telemetric neurovent-P-tel intracranial pressure sensor in a porcine model. Pediatric Neurosurg 2013;49:29–32.
- Andresen M, Juhler M. Intracranial pressure following complete removal of a small demarcated brain tumor: a model for normal intracranial pressure in humans. J Neurosurg 2014;121:797–801.
- Rapoport BI, Kedzierski JT, Sarpeshkar R. A glucose fuel cell for implantable brain–machine interfaces. PLoS One 2012;7:e38436.
- Zebda A, Cosnier S, Alcaraz J-P, et al. Single glucose biofuel cells implanted in rats power electronic devices. Nat Sci Rep 2013;3:1516
- Roseman JM, Lin J, Ramakrishnan S, et al. Hybrid integrated biological–solid-state system powered with adenosine triphosphate. Nat Commun 6:10070.
- Oxley TJ, Opie NL, John SE, et al. Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity. Nat Biotechnol 2016;34:320–7.
- Kang S-K, Murphy RKJ, Hwang S-W, et al. Bioresorbable silicon electronic sensors for the brain. Nature 2016;530:71–6.