873
Views
43
CrossRef citations to date
0
Altmetric
Articles

Test–Retest Reliability and Minimum Detectable Change Using the K4b2: Oxygen Consumption, Gait Efficiency, and Heart Rate for Healthy Adults During Submaximal Walking

, &
Pages 223-231 | Received 20 May 2011, Accepted 05 Sep 2012, Published online: 22 May 2013

References

  • Amorim , P. R. S. , Byrne , N. M. and Hills , A. P. 2009 . Within- and between-day repeatability and variability in children's physiological responses during submaximal treadmill exercise . Research Quarterly for Exercise and Sport , 80 : 575 – 582 .
  • Baker , R. , Hausch , A. and McDowell , B. 2001 . Reducing the variability of oxygen consumption measurements . Gait & Posture , 13 : 202 – 209 .
  • Berryman , N. , Gayda , M. , Nigam , A. , Juneau , M. , Bherer , L. and Bosquet , L. 2012 . Comparison of the metabolic energy cost of overground and treadmill walking in older adults . European Journal of Applied Physiology and Occupational Physiology , 112 : 1613 – 1620 .
  • Blessinger , J. , Sawyer , B. , Davis , C. , Irving , B. A. , Weltman , A. and Gaesser , G. 2009 . Reliability of the VmaxST portable metabolic measurement system . International Journal of Sports Medicine , 30 : 22 – 26 .
  • Brehm , M. A. , Becher , J. and Harlaar , J. 2007 . Reproducibility evaluation of gross and net walking efficiency in children with cerebral palsy . Developmental Medicine & Child Neurology , 49 : 45 – 48 .
  • Brehm , M. A. , Harlaar , J. and Groepenhof , H. 2004 . Validation of the portable VmaxST system for oxygen-uptake measurement . Gait & Posture , 20 : 67 – 73 .
  • Brehm , M. A. , Nollet , F. and Harlaar , J. 2006 . Energy demands of walking in persons with postpoliomyelitis syndrome: Relationship with muscle strength and reproducibility . Archives of Physical Medicine and Rehabilitation , 87 : 136 – 140 .
  • Carter , J. and Jeukendrup , A. E. 2002 . Validity and reliability of three commercially available breath-by-breath respiratory systems . European Journal of Applied Physiology , 86 : 435 – 441 .
  • Compher , C. , Frankenfield , D. , Keim , N. and Roth-Yousey , L. 2006 . Best practice methods to apply to measurement of resting metabolic rate in adults: A systematic review . Journal of the American Dietetic Association , 106 : 881 – 903 .
  • Crouter , S. E. , Antczak , A. , Hudak , J. R. , DellaValle , D. M. and Haas , J. D. 2006 . Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems . European Journal of Applied Physiology , 98 : 139 – 151 .
  • da Cunha-Filho , I. T. , Henson , H. and Protas , E. J. 2007 . Reliability of a portable gas analyzer during a 5-min walk test . American Journal of Physical Medicine & Rehabilitation , 86 : 469 – 473 .
  • Dawes , H. , Collet , J. , Ramsbottom , R. , Howells , K. , Sackley , C. and Wade , D . 2004 . Measuring oxygen cost during level walking in individuals with acquired brain injury in the clinical setting . Journal of Sport Science and Medicine , 3 : 76 – 82 .
  • De Groot , J. F. , Takken , T. , Schoenmakers , M. A. , Tummers , L. , Vanhees , L. and Helders , P. J. 2010 . Reproducibility of energy cost of locomotion in ambulatory children with spina bifida . Gait & Posture , 31 : 159 – 163 .
  • de Mendonca , G. V. and Pereira , F. D. 2008 . Between-day variability of net and gross oxygen uptake during graded treadmill walking: Effects of different walking intensities on the reliability of locomotion economy . Applied Physiology Nutrition and Metabolism , 33 : 1199 – 1206 .
  • Dobrovolny , C. L. , Ivey , F. M. , Rogers , M. A. , Sorkin , J. D. and Macko , R. F. 2003 . Reliability of treadmill exercise testing in older patients with chronic hemiparetic stroke . Archives of Physical Medicine & Rehabilitation , 84 : 1308 – 1312 .
  • Duffield , R. , Dawson , B. , Pinnington , H. C. and Wong , P. 2004 . Accuracy and reliability of a Cosmed K4b2 portable gas analysis system . Journal of Science & Medicine in Sport , 7 : 11 – 22 .
  • Eisenmann , J. C. , Brisko , N. , Shadrick , D. and Welsh , S. 2003 . Comparative analysis of the Cosmed Quark b2 and K4b2 gas analysis systems during submaximal exercise . Journal of Sports Medicine & Physical Fitness , 43 : 150 – 155 .
  • England , S. A. and Granata , K. P. 2007 . The influence of gait speed on local dynamic stability of walking . Gait & Posture , 25 : 172 – 178 .
  • Grabowski , A. , Farley , C. T. and Kram , R. 2005 . Independent metabolic costs of supporting body weight and accelerating body mass during walking . Journal of Applied Physiology , 98 : 579 – 583 .
  • Haley , S. M. and Fragala-Pinkham , M. A. 2006 . Interpreting change scores of tests and measures used in physical therapy . Physical Therapy , 86 : 735 – 743 .
  • Haugen , H. A. , Chan , L. N. and Li , F. 2007 . Indirect calorimetry: A practical guide for clinicians . Nutrition in Clinical Practice , 22 : 377 – 388 .
  • Larsson , P. U. , Wadell , K. M. , Jakobsson , E. J. , Burlin , L. U. and Henriksson-Larsen , K. B. 2004 . Validation of the MetaMax II portable metabolic measurement system . International Journal of Sports Medicine , 25 : 115 – 123 .
  • Laurent , C. M. , Meyers , M. C. , Robinson , C. A. , Strong , L. R. , Chase , C. and Goodwin , B. 2008 . Validity of the VmaxST portable metabolic measurement system . Journal of Sports Sciences , 26 : 709 – 716 .
  • Littlewood , R. A. , White , M. S. , Bell , K. L. , Davies , P. S. , Cleghorn , G. J. and Grote , R. 2002 . Comparison of the Cosmed K4 b(2) and the Deltatrac II metabolic cart in measuring resting energy expenditure in adults . Clinical Nutrition , 21 : 491 – 497 .
  • Macfarlane , D. J. 2001 . Automated metabolic gas analysis systems: A review . Sports Medicine , 31 : 841 – 861 .
  • McLaughlin , J. E. , King , G. A. , Howley , E. T. , Bassett , D. R. Jr and Ainsworth , B. E. 2001 . Validation of the COSMED K4 b2 portable metabolic system . International Journal of Sports Medicine , 22 : 280 – 284 .
  • McNaughton , L. R. , Sherman , R. , Roberts , S. and Bentley , D. J. 2005 . Portable gas analyser Cosmed K4b(2) compared to a laboratory based mass spectrometer system . Journal of Sports Medicine and Physical Fitness , 45 : 315 – 323 .
  • Meyer , T. , Georg , T. , Becker , C. and Kindermann , W. 2001 . Reliability of gas exchange measurements from two different spiroergometry systems . International Journal of Sports Medicine , 22 : 593 – 597 .
  • Perret , C. and Mueller , G. 2006 . Validation of a new portable ergospirometric device (Oxycon Mobile) during exercise . International Journal of Sports Medicine , 27 : 363 – 367 .
  • Pinnington , H. C. , Wong , P. , Tay , J. , Green , D. and Dawson , B. 2001 . The level of accuracy and agreement in measures of FEO2, FECO2 and VE between the Cosmed K4b2 portable, respiratory gas analysis system and a metabolic cart . Journal of Science & Medicine in Sport , 4 : 324 – 335 .
  • Portney , L. G. and Watkins , M. P. 2000 . “ Statistical measures of reliability ” . In Foundations of clinical research: Applications to practice , 2nd ed. , Edited by: L.G , Portney and M.P , Watkins . Upper Saddle River, NJ : Prentice Hall . pp. 565, 579–580
  • Prieur , F. , Castells , J. and Denis , C. 2003 . A methodology to assess the accuracy of a portable metabolic system (VmaxST) . Medicine & Science in Sports & Exercise , 35 : 879 – 885 .
  • Puthoff , M. L. , Darter , B. J. , Nielsen , D. H. and Yack , H. J. 2006 . The effect of weighted vest walking on metabolic responses and ground reaction forces . Medicine & Science in Sports & Exercise , 38 : 746 – 752 .
  • Schrack , J. A. , Simonsick , E. M. and Ferrucci , L. 2010 . Comparison of the Cosmed K4b(2) portable metabolic system in measuring steady-state walking energy expenditure . PLoS One , 5 : e9292
  • Schwartz , M. H. , Koop , S. E. , Bourke , J. L. and Baker , R. 2006 . A nondimensional normalization scheme for oxygen utilization data . Gait & Posture , 24 : 14 – 22 .
  • Terwee , C. B. , Bot , S. D. M. , de Boer , M. R. , van der Windt , D. A. W. M. , Knol , D. L. , Dekker , J. , … and de Vet , H. C. W. 2007 . Quality criteria were proposed for measurement properties of health status questionnaires . Journal of Clinical Epidemiology , 60 : 34 – 42 .
  • Thomas , S. S. , Buckon , C. E. , Schwartz , M. H. , Russman , B. S. , Sussman , M. D. and Aiona , M. D. 2009 . Variability and minimum detectable change for walking energy efficiency variables in children with cerebral palsy . Developmental Medicine and Child Neurology , 51 : 615 – 621 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.