147
Views
1
CrossRef citations to date
0
Altmetric
Cornea

Pneumotonometer Accuracy Using Manometric Measurements after Radial Keratotomy, Clear Corneal Incisions and Lamellar Dissection in Porcine Eyes

, , , , , & show all
Pages 1-6 | Received 12 Jan 2019, Accepted 24 Jul 2019, Published online: 22 Aug 2019

References

  • World Health Organization. Global data on visual impairments 2010. Geneva (Switzerland); 2012 [accessed 2018 Aug 18]. http://www.who.int/blindness/GLOBALDAT-AFINALforweb.pdf?ua=1.
  • Walker RE, Litovitz TL. An experimental and theoretical study of the pneumatic tonometer. Exp Eye Res. 1972;13(1):14–23.
  • Quigley HA, Langham ME. Comparative intraocular pressure measurements with the pneumatonograph and Goldmann tonometer. Am J Ophthalmol. 1975;80(2):266–73. doi:10.1016/0002-9394(75)90144-0.
  • Eisenberg DL, Sherman BG, McKeown CA, Schuman JS. Tonometry in adults and children. A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo. Ophthalmology. 1998;105(7):1173–81. doi:10.1016/S0161-6420(98)97016-6.
  • Molina N, Milla E, Bitrian E, Larena C, Martinez L. Comparison of Goldmann tonometry, pneumotonometry and the effect of central corneal thickness. Arch Soc Esp Oftalmol. 2010;85(10):325–28. doi:10.1016/j.oftal.2010.09.003.
  • Tonnu P, Ho T, Newson T, Sheikh AE, Sharma K, White E, Bunce C, Garway-Heath D. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol. 2005;89(7):851–54. doi:10.1136/bjo.2004.056622.
  • Recep OF, Hasiripi H, Cagil N, Sarikatipoglu H. Relation between corneal thickness and intraocular pressure measurement by noncontact and applanation tonometry. J Cataract Refract Surg. 2001;27(11):1787–91.
  • Lim KS, Wickremasinghe SS, Cordeiro MF, Bunce C, Khaw PT. Accuracy of intraocular pressure measurements in new zealand white rabbits. Invest Ophthalmol Vis Sci. 2005;46(7):2419–23. doi:10.1167/iovs.04-0610.
  • Mendelsohn AD, Forster RK, Mendelsohn SL, Dennis JJ, Heidemann DG, Levine IK, Parel JM, Di Maio JM. Comparative tonometric measurements of eye bank eyes. Cornea. 1987;6(3):219–25.
  • Acosta AC, Espana EM, Nose I, Orozco M, Yamamoto H, Venkatraman AS, Fantes F, Parel JM. Estimation of intraocular pressure in rabbits with commonly used tonometers. Ophthalmic Surg Lasers Imaging. 2007;38(1):43–49.
  • Abrams LS, Vitale S, Jampel HD. Comparison of three tonometers for measuring intraocular pressure in rabbits. Invest Ophthalmol Vis Sci. 1996;37(5):940–44.
  • Wright MM, Grajewski AL. Measurement of intraocular pressure after epikeratophakia. Br J Ophthalmol. 1997;81(6):448–51. doi:10.1136/bjo.81.6.448.
  • Abbasoglu OE, Bowman RW, Cavanagh HD, McCulley JP. Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy. Opthalmology. 1998;105(12):2193–96. doi:10.1016/S0161-6420(98)91215-5.
  • Tuunanen TH, Hämäläinen P, Mali M, Oksala O, Tervo T. Effect of photorefractive keratectomy on the accuracy of pneumatonometer readings in rabbits. Invest Ophthalmol Vis Sci. 1996;37(9):1810–14.
  • Vakili R, Choudhri SA, Tauber S, Shields MB. Effect of mild to moderate myopic correction by laser-assisted in situ keratomileusis on intraocular pressure measurements with goldmann applanation tonometer, tono-pen, and pneumatonometer. J Glaucoma. 2002;11(6):493–96.
  • Bayraktar S, Bayraktar Z. Central corneal thickness and intraocular pressure relationship in eyes with and without previous LASIK: comparison of goldmann applanation tonometer with pneumatonometer. Eur J Ophthalmol. 2005;15(1):81–88. doi:10.1177/112067210501500113.
  • Zadok D, Tran DB, Twa M, Carpenter M, Schanzlin DJ. Pneumotonometry versus goldmann tonometry after laser in situ keratomileusis for myopia. J Cataract Refract Surg. 1999;25(10):1344–48.
  • Duch S, Serra A, Castanera J, Abos R, Quintana M. Tonometry after laser in situ keratomileusis treatment. J Glaucoma. 2001;10(4):261–65.
  • Sastry SM, Sperduto RD, Waring GO III, Remaley NA, Lynn MJ, Blanco E, Miller DN. Radial keratotomy does not affect intraocular pressure. Refract Corneal Surg. 1993;9(6):459–64.
  • Faucher A, Gregoire J, Blondeau P. Accuracy of Goldmann tonometry after refractive surgery. J Cataract Refract Surg. 1997;23(6):832–38.
  • Scheuerle AF, Martin M, Voelcker HE, Auffarth G. Undetected development of glaucoma after radial keratotomy. J Refract Surg. 2008;24(1):51–54. doi:10.3928/1081597X-20080101-09.
  • Zhang Z, Yu H, Dong H, Wang L, Jia YD, Zhang SH. Corneal biomechanical properties changes after coaxial 2.2-mm microincision and standard 3.0-mm phacoemulsification. Int J Ophthalmol. 2016;9(2):230–34. doi:10.18240/ijo.2016.02.08.
  • Ucakhan OO, Ozkan M, Kanpolat A. Anterior chamber parameters measured by the Pentacam CES after uneventful phacoemulsification in normotensive eyes. Acta Ophthalmol. 2009;87(5):544–48. doi:10.1111/j.1755-3768.2008.01305.x.
  • Doganay S, Bozgul Firat P, Emre S, Yologlu S. Evaluation of anterior segment parameter changes using the Pentacam after uneventful phacoemulsification. Acta Ophthalmol. 2010;88(5):601–06. doi:10.1111/j.1755-3768.2008.01446.x.
  • Altan C, Bayraktar S, Altan T, Eren H, Yilmaz OF. Anterior chamber depth, iridocorneal angle width, and intraocular pressure changes after uneventful phacoemulsification in eyes without glaucoma and with open iridocorneal angles. J Cataract Refract Surg. 2004;30(4):832–38. doi:10.1016/j.jcrs.2003.08.023.
  • Huang G, Gonzalez E, Lee R, Chen YC, He M, Lin SC. Association of biometric factors with anterior chamber angle widening and intraocular pressure reduction after uneventful phacoemulsification for cataract. J Cataract Refract Surg. 2012;38(1):108–16. doi:10.1016/j.jcrs.2011.06.037.
  • Mansberger SL, Gordon MO, Jampel H, Bhorade A, Brandt JD, Wilson B, Kass MA. Reduction in intraocular pressure after cataract extraction: the ocular hypertension treatment study. Ophthalmology. 2012;119(9):1826–31. doi:10.1016/j.ophtha.2012.02.050.
  • Issa SA, Pacheco J, Mahmood U, Nolan J, Beatty S. A novel index for predicting intraocular pressure reduction following cataract surgery. Br J Ophthalmol. 2005;89(5):543–46. doi:10.1136/bjo.2004.047662.
  • Pohjalainen T, Vesti E, Uusitalo RJ, Laatikainen L. Intraocular pressure after phacoemulsification and intraocular lens implantation in nonglaucomatous eyes with and without exfoliation. J Cataract Refract Surg. 2001;27(3):426–31.
  • Shingleton BJ, Pasternack JJ, Hung JW, O’Donoghue MW. Three and five year changes in intraocular pressure after clear corneal phacoemulsification in open angle glaucoma patients, glaucoma suspects, and normal patients. J Glaucoma. 2006;15(6):494–98. doi:10.1097/01.ijg.0000212294.31411.92.
  • Poley BJ, Lindstrom RL, Samuelson TW, Schulze R. Intraocular pressure reduction after phacoemulsification with intraocular lens implantation in glaucomatous and nonglaucomatous eyes: evaluation of a causal relationship between the natural lens and open angle glaucoma. J Cataract Refract Surg. 2009;35(11):1946–55. doi:10.1016/j.jcrs.2009.05.061.
  • Liu CJ, Cheng CY, Wu CW, Lau LI, Chou JC, Hsu WM. Factors predicting intraocular pressure control after phacoemulsification in angle-closure glaucoma. Arch Ophthalmol. 2006;124(10):1390–94. doi:10.1001/archopht.124.10.1390.
  • Mathalone N, Hyams M, Neiman S, Buckman G, Hod Y, Geyer O. Long-term intraocular pressure control after clear corneal phacoemulsification in glaucoma patients. J Cataract Refract Surg. 2005;31(3):479–83. doi:10.1016/j.jcrs.2004.06.046.
  • Guan H, Mick A, Porco T, Dolan BJ. Preoperative factors associated with IOP reduction after cataract surgery. Optom Vis Sci. 2013;90(2):179–84. doi:10.1097/OPX.0b013e31827ce224.
  • Bilak S, Simsek A, Capkin M, Guler M, Bilgin B. Biometric and intraocular pressure change after cataract surgery. Optom Vis Sci. 2015;92(4):464–70. doi:10.1097/OPX.0000000000000553.
  • Zetterström C, Behndig A, Kugelberg M, Montan P, Lundstöm M. Changes in intraocular pressure after cataract surgery: analysis of the Swedish national cataract register. J Cataract Refract Surg. 2015;41(8):1725–29. doi:10.1016/j.jcrs.2014.12.054.
  • Musa FU, Patil S, Rafiq O, Galloway P, Ball J, Morrell A. Long-term risk of intraocular pressure elevation and glaucoma escalation after deep anterior lamellar keratoplasty. Clin Exp Ophthalmol. 2012;40(8):780–85. doi:10.1111/j.1442-9071.2012.02796.x.
  • Ménage MJ, Kaufman PL, Croft MA, Landay SP. Intraocular pressure measurement after penetrating keratoplasty: minified goldmann applanation tonometer, pneumatonometer, and tono-pen versus manometry. Br J Ophthalmol. 1994;78(9):671–76. doi:10.1136/bjo.78.9.671.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.