165
Views
14
CrossRef citations to date
0
Altmetric
REVIEW

Does It Really Matter What Volume to Exhale Before Using Asthma Inhalation Devices?

, PharmD, , PharmD, , PharmD & , MS, MD, FCCP
Pages 212-216 | Published online: 02 Jul 2009

References

  • Guidelines for the Diagnosis and Mangement of Asthma. National Institutes of Health. NIH Publication, Bethesda, MD 2007, Expert Panel Report 3
  • Global Initiative for Asthma (GINA). Global strategy for asthma management and prevention. 2007, www.ginasthma.org
  • Saunders K B. Misuse of inhaled bronchodilator agents. Br Med J 1965; 1: 1037–1038
  • Orehek J, Gayrard P, Grimaud C H, Charpin J. Patient error in use of bronchodilator metered aerosols. Br Med J 1976; 1: 76
  • Epstein S W, Manning C PR, Ashley M J, Corey P N. Survey of the clinical uses of pressurized aerosol inhalers. Can Med Assoc J 1979; 120: 813–816
  • Shim C, Williams M H. The adequacy of inhalation of aerosol from canister nebulizers. Am J Med 1980; 69: 891–894
  • Self T H, Brooks J B, Lieberman P, Ryan M R. The value of demonstration and role of the pharmacist in teaching the correct use of pressurized bronchodilators. Can Med Assoc J 1983; 128: 129–131
  • Goodman D E, Israel E, Rosenberg M, Johnston R, Weiss S T, Drazen J M. The influence of age, diagnosis, and gender on proper use of metered-dose inhalers. Am J Respir Crit Care Med 1994; 150: 1256–1261
  • Newman S P, Pavia D, Clarke S W. How should a pressurized beta-adrenergic bronchodilator be inhaled?. Europ J Respir Dis 1981; 62: 3–21
  • Self T H, Arnold L B, Czosnowski L M, Swanson J M, Swanson H. Inadequate skill of healthcare professionals in using asthma inhalation devices. J Asthma 2007; 44: 593–598
  • Riley D J, Weitz B W, Edelman W H. The responses of asthmatic subjects to isoproterenol inhaled at differing lung volumes. Am Rev Respir Dis 1976; 114: 509–515
  • Riley D J, Liu R T, Edelman N H. Enhanced responses to aerosolized bronchodilator therapy in asthma using respiratory maneuvers. Chest 1979; 76: 501–507
  • Thomas P, Williams T, Reilly P A, Bradley D. Modifying delivery technique of fenoterol from a metered dose inhaler. Ann Allergy 1984; 52: 279–281
  • Newman S P, Pavia D, Clarke S W. Simple instructions for using pressurized aerosol bronchodilators. J Royal Soc Med 1980; 73: 776–779
  • Dolovich M, Ruffin R E, Roberts R, Newhouse M T. Optimal delivery of aerosols from metered dose inhalers. Chest 1981; 80(Dec suppl)911–915
  • Newman S P, Pavia D, Garland N, Clarke S P. Effects of various inhalation modes on the deposition of radioactive pressurized aerosols. Eur J Respir Dis 1982; 63(suppl 119)57–65
  • Lawford P, McKenzie D. Pressurized aerosol technique. Lancet 1981; 2: 1003–1004
  • Newman S P, Pavia D, Bateman J RM, Clarke S W. Bronchodilatory response after administration of pressurized aerosols at different lung volumes in patients with airways obstruction. Clinical Sciences 1979; 56: 10P–11P
  • Hindle M, Newton D AG, Chrystyn H. Investigations of an optimal inhaler technique with the use of urinary salbutamol excretion as a measure of relative bioavailability to the lung. Thorax 1993; 48: 607–610
  • Hindle M, Chrystyn H. Determination of the relative bioavailability of salbutamol to the lung following inhalation. Br J Clin Pharmacol 1992; 34: 311–315
  • Pavia D, Thomson M L, Clarke S W, Shannon H S. Effect of lung function and mode of inhalation on penetration of aerosol into the human lung. Thorax 1977; 32: 194–197
  • Gayrard P, Orehek J, Grimaud C, Charpin J. Bronchconstrictor effects of a deep inspiration in patients with asthma. Am Rev Resp Dis 1975; 111: 433–439
  • Dolovich M, Rufin R, Corr D, Newhouse M T. Clinical evaluation of a simple demand inhalation MDI aerosol delivery device. Chest 1983; 84: 36–41
  • Tobin M J, Jenouri G, Danta I, Kim C, Watson H, Sackner M A. Response to bronchodilator drug administration by a new reservoir aerosol delivery system and a review of other auxiliary delivery systems. Am Rev Respir Dis 1982; 126: 670–675
  • Newman S P, Clark A R, Talaee N, Clarke S W. Pressurized aerosol deposition in the human lung with and without an “open” spacer device. Thorax 1989; 44: 706–710
  • Demirkan K, Tolley E, Mastin T, Soberman J, Burbeck J, Self T. Salmeterol administration by metered-dose inhaler alone vs metered-dose inhaler plus valved holding chamber. Chest 2000; 117: 1314–1318
  • Lavorini F, Magnan A, Dubus J C, Voshaar T, Corbetta L, Broeders M, Dekhuijzen R, Sanchis J, Viejo J L, Barnes P, Corrigan C, Levy M, Crompton G K. Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD. Respir Med 2008; 102: 593–604
  • Interiano B, Guntupalli K K. Metered-dose inhalers: Do health care providers know what to teach?. Arch Intern Med 1993; 153: 81–85
  • Van Beerendonk I, Mesters I, Mudde A N, Tan T D. Assessment of the inhalation technique in outpatients with asthma or COPD using a metered-dose inhaler or dry powder device. J Asthma 1998; 35: 273–279
  • Hagmolen of ten Have W, van De Berg N J, Bindels P JE, van Aalderen W MC, van der Palen J. Assessment of inhalation technique in children in general practice: increased risk of incorrect performance with new device. J Asthma 2008; 45: 67–71
  • Plaza V, Sanchis J, CESEA Group. Medical personnel and patient skill in the use of metered dose inhalers: A multicentric study. Respiration 1998; 65: 195–198
  • Ronmark E, Jogi R, Lindqvist A, Haugen T, Meren M, Loit H-M, Lairanen U, Sandahl A, Lundback B. Correct use of three powder inhalers: Comparison between Diskus, turbuhaler, and Easyhaler. J Asthma 2005; 42: 173–178
  • van d er, Palen J, Klein J J, Kerkhoff A HM, van Herwaarden C L. Evaluation of the effectiveness of four different inhalers in patients with chronic obstructive pulmonary disease. Thorax 1995; 50: 1183–1187
  • Molimard M, Rahersion C, Lignot S, Depont F, Abouelfath A, Moore N. Assessment of handling of inhaler devices in real life: an observational study of 3811 patients in primary care. J Aerosol Med 2003; 16: 249–254
  • Kelling J S, Strohl K P, Smith R L, Altose M D. Physician knowledge in the use of canister nebulizers. Chest 1983; 83: 612–614
  • Mas J C, Resnick D J, Firschein D E, Feldman B R, Davis W J. Misuse of metered dose inhalers by housestaff members. Am J Dis Child 1992; 146: 783–785
  • Self T H, Kelso T M, Arheart K L, Morgan J H, Meduri G U. Nurses' performance of inhalational technique with metered-dose inhaler plus spacer device. Ann Pharmacother 1993; 27: 185–187
  • Chafin C C, Tolley E, Demirkan K, Burbeck J, Self T H. Effect of a brief educational intervention on medical students' use of asthma devices. J Asthma 2000; 37: 585–588
  • Chopra N, Oprescu N, Fask A, Oppenheimer J. Does introduction of new “easy to use” inhalational devices improve medical personnel's knowledge of their proper use?. Ann Allergy Asthma Immunol 2002; 88: 395–400
  • Plaza V, Sanchis J, CESEA Group. Medical personnel and patient skill in the use of metered dose inhalers: A multicentric study. Respiration 1998; 65: 195–198
  • Hanania N A, Wittman R, Kesten S, Chapman K R. Medical personnel's knowledge of and ability to use inhaling devices. Metered-dose inhalers, spacing chambers, and breath-actuated dry powder inhalers. Chest 1994; 105: 111–116

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.