506
Views
10
CrossRef citations to date
0
Altmetric
Education

Inhalation technique and asthma outcomes with different corticosteroid-containing inhaler devices

, MPharm, , MPharm, PhD & , MPharm, PhD
Pages 654-662 | Received 24 Sep 2018, Accepted 03 Mar 2019, Published online: 27 Mar 2019

References

  • WHO. Asthma. 2017 [updated April 2017]. Available from: http://www.who.int/mediacentre/factsheets/fs307/en/.
  • GINA. Global Strategy for Asthma Management and Prevention. 2006 [cited 6 September 2017]. Available from: www.ginasthma.org.
  • Labiris NR, Dolovich MB. Pulmonary drug delivery. Part II: the role of inhalant delivery devices and drug formulations in therapeutic effectiveness of aerosolized medications. Br J Clin Pharmacol 2003;56:600–612. doi:10.1046/j.1365-2125.2003.01893.x.
  • Labiris NR, Dolovich MB. Pulmonary drug delivery. Part I: physiological factors affecting therapeutic effectiveness of aerosolized medications. Br J Clin Pharmacol 2003;56:588–599. doi:10.1046/j.1365-2125.2003.01892.x.
  • Johnson JL, Guthrie D, Hyde J, Hanson T, Karlage K, Myrdal PB. The effect of a holding chamber on albuterol metered-dose inhaler product differences. Ann Allergy Asthma Immunol 2016;117:246–250. doi:10.1016/j.anai.2016.07.016.
  • Padron GT, Hernandez-Trujillo VP. The effect of a holding chamber on albuterol metered-dose inhaler product differences. Pediatrics 2017;140:218–219.
  • Morisky DE, Ang A, Krousel-Wood M, Ward HJ. Predictive validity of a medication adherence measure in an outpatient setting. J Clin Hypertens (Greenwich) 2008;10:348–354. doi:10.1111/j.1751-7176.2008.07572.x.
  • Krousel-Wood M, Islam T, Webber LS, Re RN, Morisky DE, Muntner P. New medication adherence scale versus pharmacy fill rates in seniors with hypertension. Am J Manag Care 2009;15:59–66.
  • Morisky DE, DiMatteo MR. Improving the measurement of self-reported medication nonadherence: response to authors. J Clin Epidemiol 2011;64:255–257. doi:10.1016/j.jclinepi.2010.09.002.
  • Janezic A, Locatelli I, Kos M. Criterion validity of 8-item Morisky Medication Adherence Scale in patients with asthma. PLoS One 2017;12:e0187835.doi:10.1371/journal.pone.0187835.
  • Schatz M, Sorkness CA, Li JT, Marcus P, Murray JJ, Nathan RA, Kosinski M, et al. Asthma Control Test: reliability, validity, and responsiveness in patients not previously followed by asthma specialists. J Allergy Clin Immunol 2006;117:549–556. doi:10.1016/j.jaci.2006.01.011.
  • Jones PW, Quirk FH, Baveystock CM, Littlejohns P. A self-complete measure of health status for chronic airflow limitation. The St. George's Respiratory Questionnaire. Am Rev Respir Dis 1992;145:1321–1327. doi:10.1164/ajrccm/145.6.1321.
  • Lavorini F, Magnan A, Dubus JC, Voshaar T, Corbetta L, Broeders M, Dekhuijzen R, et al. Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD. Respir Med 2008;102:593–604. doi:10.1016/j.rmed.2007.11.003.
  • Chrystyn H, van der Palen J, Sharma R, Barnes N, Delafont B, Mahajan A, Thomas M. Device errors in asthma and COPD: systematic literature review and meta-analysis. NPJ Prim Care Respir Med 2017;27:22.
  • Armour CL, Lemay K, Saini B, Reddel HK, Bosnic-Anticevich SZ, Smith LD, Burton D, et al. Using the community pharmacy to identify patients at risk of poor asthma control and factors which contribute to this poor control. J Asthma 2011;48:914–922. doi:10.3109/02770903.2011.615431.
  • Molimard M, Raherison C, Lignot S, Depont F, Abouelfath A, Moore N. Assessment of handling of inhaler devices in real life: an observational study in 3811 patients in primary care. J Aerosol Med 2003;16:249–254.
  • Chrystyn H. The Diskus: a review of its position among dry powder inhaler devices. Int J Clin Pract 2007;61:1022–1036. doi:10.1111/j.1742-1241.2007.01382.x.
  • Palander A, Mattila T, Karhu M, Muttonen E. In vitro comparison of three salbutamol-containing multidose dry powder inhalers. Clin Drug Invest 2000;20:25–33. doi:10.2165/00044011-200020010-00004.
  • Hoppentocht M, Hagedoorn P, Frijlink HW, de Boer AH. Technological and practical challenges of dry powder inhalers and formulations. Adv Drug Deliv Rev 2014;75:18–31. doi:10.1016/j.addr.2014.04.004.
  • Newman SP, Busse WW. Evolution of dry powder inhaler design, formulation, and performance. Respir Med 2002;96:293–304.
  • Giraud V, Roche N. Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability. Eur Respir J 2002;19:246–251.
  • Newman SP, Weisz AW, Talaee N, Clarke SW. Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique. Thorax 1991;46:712–716. doi:10.1136/thx.46.10.712.
  • Vincken W, Levy ML, Scullion J, Usmani OS, Dekhuijzen PNR, Corrigan CJ. Spacer devices for inhaled therapy: why use them, and how? ERJ Open Res 2018;4:00065–2018.
  • Lavorini F, Usmani OS. Correct inhalation technique is critical in achieving good asthma control. Prim Care Respir J 2013;22:385–386. doi:10.4104/pcrj.2013.00097.
  • Melani AS, Bonavia M, Cilenti V, Cinti C, Lodi M, Martucci P. Inhaler mishandling remains common in real life and is associated with reduced disease control. Respir Med 2011;105:930–938.
  • Al Ammari M, Sultana K, Yunus F, Al Ghobain M, Al Halwan SM. A cross-sectional observational study to assess inhaler technique in Saudi hospitalized patients with asthma and chronic obstructive pulmonary disease. Saudi Med J 2016;37:570–574. doi:10.15537/smj.2016.5.14369.
  • Burgess S, Sly P, Devadason S. Adherence with preventive medication in childhood asthma. Pulm Med 2011;2011:973849.doi:10.1155/2011/973849.
  • Makela MJ, Backer V, Hedegaard M, Larsson K. Adherence to inhaled therapies, health outcomes and costs in patients with asthma and COPD. Respir Med 2013;107:1481–1490. doi:10.1016/j.rmed.2013.04.005.
  • Taylor TE, Zigel Y, Egan C, Hughes F, Costello RW, Reilly RB. Objective assessment of patient inhaler user technique using an audio-based classification approach. Sci Rep 2018;8:2164.
  • Taylor TE, Zigel Y, De Looze C, Sulaiman I, Costello RW, Reilly RB. Advances in audio-based systems to monitor patient adherence and inhaler drug delivery. Chest 2018;153:710–722. doi:10.1016/j.chest.2017.08.1162.
  • Sulaiman I, Greene G, MacHale E, Seheult J, Mokoka M, D'Arcy S, Taylor T, et al. A randomised clinical trial of feedback on inhaler adherence and technique in patients with severe uncontrolled asthma. Eur Respir J 2018;51:1701126.
  • Seheult JN, O’Connell P, Tee KC, Bholah T, Al Bannai H, Sulaiman I, MacHale E, et al. The acoustic features of inhalation can be used to quantify aerosol delivery from a Diskus™ dry powder inhaler. Pharm Res 2014;31:2735–2747.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.