References
- Aceti , A , Celestino , D , Teggi , A , Caferro , M , Pennica , A , Grilli , A , Sebastiani , A and De Rosa , F . 1989 . Histamine release test in the diagnosis of human hydatidosis . Clinical & Experimental Allergy , 19 : 335 – 9 .
- Alam , MK , Sasaki , M , Watanabe , T and Maeyama , K . 1995 . Simultaneous determinations of histamine and N tau-methylhistamine by high-performance liquid chromatography-chemiluminescence coupled with immobilized diamine oxidase . Analytical Biochemistry , 229 : 26 – 34 .
- Arakawa , Y and Tachibana , S . 1986 . A direct and sensitive determination of histamine in acid-deproteinized biological samples by high-performance liquid chromatography . Analytical Biochemistry , 158 : 20 – 7 .
- Bettero , A , Angi , MR , Moro , F and Benassi , CA . 1984 . Histamine assay in tears by fluorescamine derivatization and high-performance liquid chromatography . Journal of Chromatography , 310 : 390 – 5 .
- Czerwonka , R , Tsikas , D and Brunner , G . 1988 . High-performance liquid chromatographic determination of plasma histamine after pre-column derivatisation with o-phthalaldialdehyde . Chromatographia , 25 : 219 – 22 .
- Devalia , JL , Sheinman , BD and Davies , RJ . 1985 . Highly sensitive high-performance liquid chromatographic technique for the simultaneous measurement of histamine, 1-methylhistamine and other biogenic amines . Journal of Chromatography , 343 : 407 – 12 .
- Frattini , V and Lionetti , C . 1998 . Histamine and histidine determination in tuna fish samples using high-performance liquid chromatography. Derivatization with omicronphthalaldehyde and fluorescence detection or UV detection of “free” species . Journal of Chromatography A , 809 : 241 – 5 .
- Granerus , G and Wass , U . 1984 . Urinary excretion of histamine, methylhistamine (1-MeHi) and methylimidazoleacetic acid (MeImAA) in mastocytosis: Comparison of new HPLC methods with other present methods . Agents Actions , 14 : 341 – 5 .
- Guesdon , JL , Chevrier , D , Mazie , JC , David , B and Avrameas , S . 1986 . Monoclonal anti-histamine antibody. Preparation, characterization and application to enzyme immunoassay of Ristaniney . Journal of Immunological Methods , 87 : 69 – 78 .
- Harsing , LG , Nagashima , H Jr , Duncalf , D , Vizi , ES and Goldiner , PL . 1986 . Determination of histamine concentrations in plasma by liquid chromatography/electrochemistry . Clinical Chemistry , 32 : 1823 – 7 .
- Harvima , RJ , Harvima , IT , Tuomisto , L , Horsmanheimo , M and Fraki , JE . 1989 . Comparison of histamine assay methods in measuring in vitro-induced histamine release in patients with allergic rhinitis . Allergy , 44 : 235 – 9 .
- Inoue , H , Hisamatsu , KI , Yamauchi , M and Kumagai , N . 2001 . Rapid and simple determination of histamine-N-methyl transferase activity by high-performance liquid chromatography with UV detection . Mediators of Inflammation , 10 : 273 – 7 .
- Itoh , Y , Oishi , R , Adachi , N and Saeki , K . 1992 . A highly sensitive assay for histamine using ion-pair HPLC coupled with postcolumn fluorescent derivatization: Its application to biological specimens . Journal of Neurochemistry , 58 : 884 – 9 .
- Leino , L , Juhakoski , A and Lauren , L . 1990 . The determination of histamine in challenged human leukocyte preparations by high-performance liquid chromatography . Agents Actions , 31 : 178 – 82 .
- May , S , Sturman , G and Perrett , D . 1999 . Determination of histamine in tissues using reversed phase-HPLC with post column fluorimetric detection . Inflammation Research , 48 : 94 – 5 .
- Mita , H , Yasueda , H and Shida , T . 1980 . Simultaneous determination of histamine and N tau-methylhistamine in human plasma and urine by gas chromatography–mass spectrometry . Journal of Chromatography , 221 : 1 – 7 .
- Nishi , H , Nishimura , S , Higashiura , M , Ikeya , N , Ohta , H , Tsuji , T , Nishimura , M , Ohnishi , S and Higashi , H . 2000 . A new method for histamine release from purified peripheral blood basophils using monoclonal antibody-coated magnetic beads . Journal of Immunological Methods , 240 : 39 – 46 .
- Robert , JC , Vatier , J , Nguyen Phuoc , BK and Bonfils , S . 1983 . Determination of histamine, methylhistamines and histamine-o-phthaldialdehyde complexes by two high-performance liquid chromatographic procedures. Application to biological samples . Journal of Chromatography , 273 : 275 – 87 .
- Takeda , J , Ueda , E , Takahashi , J and Fukushima , K . 1995 . Plasma N-methylhistamine concentration as an indicator of histamine release by intravenous d-tubocurarine in humans: Preliminary study in five patients by radioimmunoassay kits . Anesthesia & Analgesia , 80 : 1015 – 7 .
- Tsuruta , Y , Kohashi , K and Ohkura , Y . 1981 . Simultaneous determination of histamine and N tau-methylhistamine in human urine and rat brain by high-performance liquid chromatography with fluorescence detection . Journal of Chromatography , 224 : 105 – 10 .
- van Haaster , CM , Engels , W , Lemmens , PJ , Hornstra , G and van der Vusse , GJ . 1993 . Rapid and highly sensitive high-performance liquid chromatographic method for the determination of histamine and 3-methylhistamine in biological samples using fluorescamine as the derivatizing agent . Journal of Chromatography , 617 : 233 – 40 .
- Walters , DL , James , JE , Vest , FB and Karnes , HT . 1994 . A comparison of fluorescence versus chemiluminescence detection for analysis of the fluorescamine derivative of histamine by HPLC . Biomedical Chromatography , 8 : 207 – 11 .
- Withington , DE and Aranda , JV . 1997 . Measurement of plasma histamine by high performance liquid chromatography and radioimmunoassay . Inflammation Research , 46 : S77 – 8 .