7,405
Views
84
CrossRef citations to date
0
Altmetric
Original Articles

History of Impactors—The First 110 Years

Pages 247-292 | Received 01 Sep 2003, Accepted 01 Oct 2003, Published online: 17 Aug 2010

REFERENCES

  • ACGIH . 1960 . Air Sampling Instruments , 1st ed. , Cincinnati, Ohio : American Conference of Governmental Industrial Hygienists .
  • ACGIH . 1962 . Air Sampling Instruments , 2nd ed. , Cincinnati, Ohio : American Conference of Governmental Industrial Hygienists .
  • ACGIH . 1967 . Air Sampling Instruments , 3rd ed. , Cincinnati, Ohio : American Conference of Governmental Industrial Hygienists .
  • ACGIH . 1972 . Air Sampling Instruments , 4th ed. , Cincinnati, Ohio : American Conference of Governmental Industrial Hygienists .
  • ACGIH . 1978 . Air Sampling Instruments , 5th ed. , Cincinnati, Ohio : American Conference of Governmental Industrial Hygienists .
  • ACGIH . 1983 . Air Sampling Instruments , 6th ed. , Cincinnati, Ohio : American Conference of Governmental Industrial Hygienists .
  • ACGIH . 1989 . Air Sampling Instruments , 7th ed. , Cincinnati, Ohio : American Conference of Governmental Industrial Hygienists .
  • ACGIH . 1995 . Air Sampling Instruments , 8th ed. , Cincinnati, Ohio : American Conference of Governmental Industrial Hygienists .
  • ACGIH . 2001 . Air Sampling Instruments , 9th ed. , Cincinnati, Ohio : American Conference of Governmental Industrial Hygienists .
  • Aitken , J. 1888 . On the Number of Dust Particles in the Atmosphere . Transactions of the Royal Society of Edinburgh , Vol. XXXV (from the Collected Papers of John Aitken, by C. Knott for the Royal Society of Edinburgh, 1923, pp. 187–206)
  • Aitken , J. 1889 . On Improvements in the Apparatus for Counting the Dust Particles in the Atmosphere . Transactions of the Royal Society of Edinburgh , Vol. XVI (from the Collected Papers of John Aitken, by C. Knott for the Royal Society of Edinburgh, 1923, pp. 207–235)
  • Andersen , A. A. 1956 . “ Development Work on the Andersen Sampler ” . In Dugway Proving Ground Research Report 108 , Utah : Dugway . November 13, 1956
  • Andersen , A. A. 1958 . New Sampler for the Collection, Sizing, and Enumeration of Viable Airborne Particles . J. Bact. , 76 : 471 – 484 .
  • Andersen , A. A. 1966 . A Sampler for Respiratory Health Hazard Assessement . Am. Ind. Hyg. Assoc. J. , 27 : 160 – 165 .
  • Beadle , D. G. 1951 . An Investigation of the Performance and Limitations of the Konimeter . J. Chem. Metallurg. Mining Soc. of South Africa , 51 : 265 – 293 .
  • Berner , A. , Lürzer , C. H. , Pohl , L. , Preining , O. and Wagner , P. 1979 . The Size Distribution of the Urban Aerosol in Vienna . Sci. Total Environ. , 13 : 245 – 261 .
  • Bourdillon , R. B. , Lidwill , O. M. and Thomas , J. C. 1941 . A Slit Sampler for Collecting and Counting Air-Borne Bacteria . J. Hygiene , XLI : 197 – 224 .
  • Brink , J. A. 1958 . Cascade Impactor for Adiabatic Measurements . Indus. Eng. Chem. , 50 ( 4 ) : 645 – 648 .
  • Buchholz , H. 1970a . An Underpressure Cascade Impactor . Staub Reinhalt. Luft , 30 ( 4 ) : 17 – 20 .
  • Buchholz , H. 1970b . On the Separation of Airborne Matter by Inertia Effect in the Submicronic Range . Staub Reinhalt. Luft , 30 ( 5 ) : 15 – 22 .
  • Chaun , R. L. 1970 . An Instrument for the Direct Measurement of Particulate Mass . Aerosol Sci. , 1 : 111 – 114 .
  • Chaun , R. L. 1976 . “ Rapid Measurement of Particulate Size Distribution in the Atmosphere ” . In Fine Particles Aerosol Generation, Measurement, Sampling and Analysis , Edited by: Liu , B. Y. H. pp. 763 – 775 . New York : Academic Press, Inc. .
  • Cohen , J. J. and Montan , D. N. 1967 . Theoretical Considerations, Design, and Evaluation of a Cascade Impactor . American Indus. Hygiene Assoc. J. , 28 : 95 – 104 .
  • Davies , C. N. and Aylward , M. 1951 . The Trajectories of Heavy, Solid Particles in a Two-Dimensional Jet of Ideal Fluid Impinging Normally upon a Plate . Pro. Phys. Soc. (London) , B 64 : 889 – 911 .
  • Davies , C. N. , Aylward , M. and Leacey , D. 1951 . Impingement of Dust from Air Jets . A.M.A. Arch. Ind. Hyg. Occupational Med. , 4 : 354 – 397 .
  • Fairchild , C. I. and Wheat , L. D. 1984 . Calibration and Evaluation of a Real-Time Cascade Impactor . Am. Ind. Hyg. Assoc. J. , 45 ( 4 ) : 205 – 211 .
  • Flesch , J. P. , Norris , C. H. and Nugent , A. T. 1967 . Calibrating Particulate Air Samplers with Monodisperse Aerosols: Application to the Andersen Cascade Impactor . Am. Ind. Hyg. Assoc. J. , 28 : 507 – 516 .
  • Franzen , H. and Fissan , H. 1979 . Evaluation of Cascade Impactor Measurements Taking into Account Wall Losses and Non-Ideal Collection Efficiencies . Staub Reinhalt Luft. , 39 : 50
  • Gosman , A. D. , Pun , W. M. , Runchal , A. K. , Spalding , D. B. and Wolfshtein , W. 1969 . Heat and Mass Transfer in Recirculating Flows , New York : Academic Press .
  • Green , H. L. and Watson , H. H. 1935 . “ Physical Methods for the Estimation of the Dust Hazard in Industry (with Special Reference to the Occupation of the Stonemason) ” . In Medical Research Council, Special Report Series, No. 199 London
  • Greenburg , L. and Bloomfield , J. J. 1932 . The Impinger Dust Sampling Apparatus as Used by the United States . Public Health Service, Public Health Reports , 47 ( 12 ) : 654 – 675 .
  • Greenburg , L. and Smith , G. W. 1922 . “ A New Instrument for Sampling Aerial Dust ” . In U. S. Bureau of Mines, Reports of Investigations, Serial No. 2392 , Department of the Interior .
  • Gurney , S. W. , Williams , C. R. and Meigs , R. R. 1938 . Investigation of the Characteristics of the Bausch & Lomb Dust Counter . J. Indus. Hygiene Toxicol. , 20 ( 1 ) : 24 – 35 .
  • Gussman , R. A. and Gordon , D. 1966 . Notes on the Modification and Use of a Cascade Impactor for Sampling in Ducts . Amer. Indus. Hygiene Assoc. J. , 27 : 252 – 255 .
  • Hatch , T. , Warren , H. and Drinker , P. 1932 . Modification of the Greenburgh-Smith Impinger for Field Use, with a Study of its Operating Characteristics . J. Indus. Hygiene , 14 ( 8 ) : 301 – 311 .
  • Hering , S. V. , Flagan , R. C. and Friedlander , S. K. 1978 . Design and Evaluation of New Low-Pressure Impactor. 1 . Environ. Sci. Technol. , 12 ( 6 ) : 667 – 673 .
  • Hering , S. V. , Friedlander , S. K. , Collins , J. J. and Richards , L. W. 1979 . Design and Evaluation of New Low-Pressure Impactor. 2 . Environ. Sci. Technol. , 13 ( 2 ) : 184 – 188 .
  • Hillamo , R. E. and Kaupinen , E. I. 1991 . On the Performance of the Berner Low Pressure Impactor . Aerosol Sci. Technol. , 14 : 33 – 47 .
  • Hill , E. V. 1917 . Quantitative Determination of Air Dust . Heating Ventilating Magazine , 14 : 23 – 33 .
  • Horton , K. D. , Ball , M. H. E. and Mitchell , J. P. 1992 . The Calibration of a California Measurements PC-2 Quartz Crystal Cascade Impactor (QCM) . J. Aerosol Sci. , 23 ( 5 ) : 505 – 524 .
  • Iron & Coal Trades Review . 1934 . Selective Dust Sampling: Modified Ziess Konimeter . Iron & Coal Trades Rev. , 128 : 840
  • Jones , W. , Morring , K. , Morey , P. and Sorenson , W. 1985 . Evaluation of the Andersen Viable Impactor for Single Stage Sampling . Am. Ind. Hyg. Assoc. J. , 46 ( 5 ) : 294 – 298 .
  • Katz , S. H. , Smith , G. W. , Myers , W. M. , Trostel , L. J. , Ingels , M. and Greenburgh , L. 1925 . Comparative Tests of Instruments for Determining Atmospheric Dusts . U.S. Public Health Bulletin No. 144. ,
  • Katz , S. H. and Trostel , L. J. 1922 . Dustiness of the Air in Granite-Cutting Plants . Trans. Amer. Soc. Heating Ventilating Eng. , 28 : 235 – 263 . (Paper No. 632)
  • Keskinen , J. , Pietarinen , K. and Lehtimäki , M. 1992 . Electrical Low Pressure Impactor . J. Aerosol Sci. , 23 ( 4 ) : 353 – 360 .
  • Kotzé , R. N. 1923 . A New Method of Dust Determination . J. Chemical Metallurg. Mining Soc. , XXIV ( 1 ) : 1 – 6 .
  • Kusnetz , H. L. 1962 . “ Inertial Collectors ” . In Air Sampling Instruments , Second Edition , Cincinnati, Ohio : American Conference of Governmental Industrial Hygienists .
  • Laskin , S. 1949 . “ Measurement of Particle Size ” . In Pharmacology and Toxicology of Uranium Compounds , Edited by: Voegtlin , C. and Hodge , H. C. New York : McGraw Hill Book Co. .
  • Lidwell , O. M. and Noble , W. C. 1965 . A Modification of the Andersen Sampler for Use in Occupied Environments . J. Appl. Bacteriol. , 28 : 280 – 282 .
  • Lidwell , O. M. 1966 . Discussion . Bacteriol. Rev. , 30 : 573 – 575 .
  • Lilienfeld , P. and Dulchinos , J. 1972 . Portable Instantaneous Mass Monitor for Coal Mine Dust . American Indus. Hygiene Assoc. J. , 33 ( 3 ) : 136 – 145 .
  • Lippmann , M. 1959 . Review of Cascade Impactors for Particle Size analysis and a New Calibration for the Casella Cascade Impactor . Am. Indus. Hygiene Assoc. J. , 20 : 406 – 416 .
  • Lippmann , M. 1961 . A Compact Cascade Impactor for Field Survey Sampling . Am. Industrial Hygiene Assoc. J. , 22 : 348 – 353 .
  • Lundgren , D. A. 1967 . An Aerosol Sampler for Determination of Particle Concentration as a Function of Size and Time . J. Air Pollut. Control Assoc. , 17 ( 4 ) : 225 – 229 .
  • Maddox , R. L. 1870 . On the Apparatus for Collecting Atmospheric Particles . Monthly Microscopical J. , 1 : 286 – 290 .
  • Maddox , R. L. 1871 . Observations on the Use of the Aëroconiscope, or Air-dust Collecting Apparatus . Monthly Microscopical J. , 1 : 45 – 49 .
  • Marjamäki , M. , Keskinen , J. , Chen , D. and Pui , D. 2000 . Performance evaluation of the Electrical Low-Pressure Impactor (ELPI) . J. Aerosol Sci. , 31 ( 2 ) : 249 – 261 .
  • Marple , V. A. 1970 . A Fundamental Study of Inertial Impaction , Minneapolis Minnesota, , USA : University of Minnesota . Ph.D. thesis
  • Marple , V. A. 1995 . “ History of Aerosol Impactors ” . In AAAR Abstracts of the 1995 Annual Conference pp. 203 Pittsburgh, PA October 9–13
  • Marple , V. A. , Roberts , D. L. , Romay , F. J. , Miller , N. C. , Truman , K. G. , Van Oort , M. , Olsson , B. , Holroyd , M. J. , Mitchell , J. P. and Hochrainer , D. 2003 . Next Generation Pharmaceutical Impactor (A New Impactor for Pharmeceutical Inhaler Testing)—Part I: Design . J. Aerosol Med. , 16 : 283 – 299 .
  • Marple , V. A. and Rubow , K. L. 1978 . An Evaluation of the GCA Respirable Dust Monitor 101–1 . Amer. Indus. Hygiene Assoc. J. , 39 ( 1 ) : 17 – 25 .
  • Marple , V. A. , Rubow , K. L. and Behm , S. M. 1991 . A Microorifice Uniform Deposit Impactor (MOUDI): Description, Calibration, and Use . Aerosol Sci. Technol. , 14 : 434 – 446 .
  • Mavrogordato , A. 1923 . The Value of the Konimeter—Being an Investigation into the Methods and Results of Dust-Sampling as at Present Practiced in the Mines . Pub. South African Inst. Med. Res. , 2 ( Pub. No. XVII ) : 215 – 286 .
  • May , K. R. 1945 . The Cascade Impactor: An Instrument for Sampling Coarse Aerosols . J. Sci. Instr. , 22 : 187 – 195 .
  • May , K. R. 1956 . A Cascade Impactor with Moving Slides . A. M. A. Archives of Indus. Health , 31 : 481 – 488 .
  • May , K. R. 1964 . Calibration of a Modified Andersen Bacterial Aerosol Sampler . Appl. Microbiol. , 12 ( 1 ) : 37 – 43 .
  • May , K. R. 1965 . An Eyepiece Graticule for Particle Sizing . J. Sci. Instr. , 42 : 500 – 501 .
  • May , K. R. 1966 . Multistage Liquid Impinger . Bacteriolog. Rev. , 30 ( 3 ) : 559 – 560 .
  • May , K. R. 1975 . Design of the Ultimate Impactor . J. Aerosol Sci. , 6 ( 1 ) : 413 – 419 .
  • May , K. R. 1977 . “ A Personal Note on the History of the Cascade Impactor Development ” . In 70th Annual Conference of the Air Pollution Control Association Toronto, Ontario June 20–24
  • May , K. R. 1982 . A Personal Note on the History of the Cascade Impactor . J. Aerosol Sci. , 13 ( 1 ) : 37 – 47 .
  • McFarland , A. R. , Wedding , J. B. and Cermak , J. E. 1977 . Wind Tunnel Evaluation of a Modified Andersen Impactor and an All Weather Sampler Inlet . Atmos. Environ. , 11 : 535 – 539 .
  • Mercer , T. T. and Chow , H. Y. 1968 . Impaction from Rectangular Jets . J. Colloid Interface Sci. , 27 ( 1 ) : 75 – 83 .
  • Mercer , T. T. and Stafford , R. G. 1969 . Impaction from Round Jets . Ann. Occup. Hyg. , 12 : 41 – 48 .
  • Mercer , T. T. , Tillery , M. T. and Newton , G. J. 1970 . A Multi-Stage, Low Flow Rate Cascade Impactor . J. Aerosol Sci. , 1 : 9 – 15 .
  • Michaelis , H. 1890 . Prufung der Wirksamkeit von Staubrespiratoren . Zietschrift für Hygiene. , 9 : 389 – 394 .
  • Miquel , M. P. 1879 . Etude sur les Poussieres Organisees de L'Atmosphere . Annales D'Hygiene Publique et De Medecine Legale , : p. 226 Janvier 1879
  • Mitchell , J. P. , Costa , P. A. and Waters , S. 1988 . An Assessment of an Andersen Mark-II Cascade Impactor . J. Aerosol Sci. , 19 ( 2 ) : 213 – 221 .
  • Mitchell , R. I. and Pilcher , J. M. 1959 . Improved Cascade Impactor for Measuring Aerosol Particle Sizes in Air Pollutants, Commercial Aerosols and Cigarette Smoke . Indus. Eng. Chem. , 51 : 1039 – 1042 .
  • Owens , J. S. 1922 . Suspended Impurity in the Air . Proc. Royal Soc. London, Series A , CI : 18 – 37 .
  • Owens , J. S. 1923 . Jet Dust Counting Apparatus . J. Indus. Hygiene , IV : 522 – 534 .
  • Pilat , M. J. , Ensor , D. S. and Bosch , J. C. 1970 . Source Test Cascade Impactor . Atmos. Environ. , 4 : 671 – 679 .
  • Pilcher , J. M. , Mitchell , R. I. and Thomas , R. E. 1955 . The Cascade Impactor for Particle-Size Analysis of Aerosols . Proceedings of the 42nd Annual Meeting of the Chemical Specialties Manufacturers Association , December 6–7
  • Ranz , W. E. and Wong , J. B. 1952a . Impaction of Dust and Smoke Particles . I & E Chem. , 44 : 1371
  • Ranz , W. E. and Wong , J. B. 1952b . Jet Impactors for Determining the Particle-Size Distributions of Aerosols . A.M.A. Achieves of Industrial Hygiene and Occupational Medicine. , 5 : 464 – 477 .
  • Rao , A. K. and Whitby , K. T. 1979 . Non-Ideal Collection Characteristics of Inertial Impactors—II. Cascade Impactors . J. Aerosol Sci. , 9 : 87 – 100 .
  • Riediger , G. 1974 . Uber den Einsatz des Andersen-Kaskadenimpaktors in der Gewerbehygeinischen Pruftechnik, Speziell zur Bestimmung des Fraktionsabscheidegrades . Staub. , 34 : 287 – 262 .
  • Solomon , W. R. and Gilliam , J. A. 1970 . A Simplified Application of the Andersen Sampler to the Study of Airborne Fungus Particles . J. Allergy Clin. Immunol. , 45 : 1 – 13 .
  • Sonkin , L. S. 1946 . A Modified Cascade Impactor . J. Indus. Hygiene Toxicol. , 28 ( 6 ) : 269 – 272 .
  • Stern , S. C. , Zeller , H. W. and Schedman , A. I. 1962 . Collection Efficiency of Jet Impactors at Reduced Pressures . I & EC Fundamentals , 1 ( 4 ) : 273 – 277 .
  • Tanaka , S. , Kobayashi , E. and Hashimoto , Y. 1983 . Aerosol Collection Characteristics of the Andersen Sampler for Different Collection Surfaces . Japan Soc. Air Pollut. J. , 18 : 256 – 262 .
  • Troop , R. J. , Kuhn , P. J. and Brock , J. R. 1980 . A New Method for Measuring the Particle Size Distribution of Aerosols . Rev. Sci. Instrum. , 51 ( 4 ) : 516 – 520 .
  • Vaughan , N. P. 1986 . The Andersen Impactor . Health and Safety Executive, internal report , IR/L/DS/86/7
  • Vaughan , N. P. 1989 . The Andersen Impactor: Calibration, Wall Losses and Numerical Simulation . J. Aerosol Sci. , 20 ( 1 ) : 67 – 90 .
  • Wang , H. and John , W. 1988 . Characteristics of the Berner Impactor for Sampling Inorganic Ions . Aerosol Sci. Technol. , 8 ( 2 ) : 157 – 172 .
  • Wells , B. J. 1967 . An Evaluation of the May Type Cascade Impactor . Health Phys. , 13 : 1001 – 1013 .
  • Wilcox , J. D. 1953 . Design of a New Five-Stage Cascade Impactor . Archive Indus. Hygiene Occupational Med. , 7 : 376 – 382 .
  • Wilcox , J. D. 1955 . A Sampling Technique for Small Air-Borne Particulates . A.M.A. Archives of Industrial Health , 11 : 422 – 424 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.