References
- Chen, X., and J. Jiang. (2018). Retrieving the Ion Mobility Ratio and Aerosol Charge Fractions for a Neutralizer in Real-world Applications. Aerosol Sci. Technol. (in press) doi: 10.1080/02786826.2018.1498587
- Fuchs, N. A. (1963). On the Stationary Charge Distribution on Aerosol Particles in a Bipolar Ionic Atmosphere. Geofis. Pura Appl., 56:185–193.
- Hagen, D. E., and D. J. Alofs. (1983). Linear Inversion Method to Obtain Aerosol Size Distributions from Measurements with a Differiential Mobility Analyzer. Aerosol Sci. Technol., 2:465–475.
- Hoppel, W. A., and G. M. Frick. (1986). Ion-Aerosol Attachment Coefficients and the Steady-State Charge Distribution on Aerosols in a Bipolar Ion Environment. Aerosol Sci. Technol., 5:1–21.
- Jiang, J., M. Chen, C. Kuang, M. Attoui, and P. H. McMurry. (2011). Electrical Mobility Spectrometer Using a Diethylene Glycol Condensation Particle Counter for Measurement of Aerosol Size Distributions Down to 1 nm. Aerosol Sci. Technol., 45:510–521.
- Jiang, J., C. Kim, X. Wang, M. R. Stolzenburg, S. L. Kaufman, C. Qi, G. J. Sem, H. Sakurai, N., Hama, and P. H. McMurry. (2014). Aerosol Charge Fractions Downstream of Six Bipolar Chargers: Effects of Ion Source, Source Activity, and Flowrate. Aerosol Sci. Technol., 48:1207–1216.
- Knutson, E. O., and K. T. Whitby. (1975). Aerosol Classification by Electric Mobility: Apparatus, Theory, and Applications. J. Aerosol Sci., 6:443–451.
- Lopez-Yglesias, X., and R. C. Flagan. (2013). Ion-Aerosol Flux Coefficients and the Steady-State Charge Distribution of Aerosols in a Bipolar Ion Environment. Aerosol Sci. Technol, 47:688–704.
- Steiner, G., T. Jokinen, H. Junninen, M. Sipila, T. Petaja, D. Worsnop, G. P. Reischl, and M. Kulmala. (2014). High-Resolution Mobility and Mass Spectrometry of Negative Ions Produced in a 241Am Aerosol Charger. Aerosol Sci. Technol., 48:261–270.
- Tigges, L., A. Jain, and H. J. Schmid. (2015). On the Bipolar Charge Distribution Used for Mobility Particle Sizing: Theoretical Considerations. J. Aerosol Sci., 88:119–134.
- Wang, S. C., and R. C. Flagan. (1990). Scanning Electrical Mobility Spectrometer. Aerosol Sci. Technol., 13: 230–240.
- Wiedensohler, A. (1988). An Approximation of the Bipolar Charge Distribution for Particles in the Sub-micron Size Range. J. Aerosol Sci., 19:387–389.
- Wiedensohler, A., A. Wiesner, K. Weinhold, W. Birmili, M. Hermann, M. Merkel, T. Müller, S. Pfeifer, A. Schmidt, T. Tuch, F. Velarde, P. Quincey, S. Seeger, and A. Nowak. (2018). Mobility Particle Size Spectrometers: Calibration Procedures and Measurement Uncertainties. Aerosol Sci. Technol., 52:146–164.