References
- Baron , P. A. ( 1986 ). Calibration and Use of the Aerodynamic Particle Sizer (APS 3300) . Aerosol Sci. Technol. 5 : 55 – 67 .
- Bell , J. H. , Brown , K. , and Glasby , J. ( 1973 ). Variation in Delivery of Isoprenaline Form Various Pressurized Inhalers . J. Pharm. Pharmac. 25 ( Suppl. ): 32P – 36P .
- Byron , P. R. , Kelly , E. L. , Kontny , M. J. , Lovering , E. G. , Poochikian , G. K. , Sethi , S. , Thiel , C. G. , and Vadas , E. B. ( 1994 ). Recommendations of the USP Advisory Panel on Aerosols on the USP General Chapters on Aerosols ⟨601⟩ and Uniformity of Dosage Units ⟨905⟩ . Pharm. Forum 20 : 7477 – 7503 .
- Clark , A. R. , and Hollingworth , A. M. ( 1993 ). The Relationship Between Powder Inhaler Resistance and Peak Inspiratory Conditions in Healthy Volunteers—Implications fo. In Vitro Testing. J. Aerosols Med. 6 : 99 – 110 .
- Ganderton , D. ( 1996 ). The Revision of the “Inhalanda” Monograph of the European Pharmacopoeia . Pharmeuropa 8 : 245 – 258 .
- Kenny , L. C. , and Lideacuten , G. ( 1991 ). A Technique for Assessing Size-selective Dust Samplers Using the APS and Polydisperse Test Aerosols . J. Aerosol Sci. 22 : 91 – 100 .
- Lodge , J. P. , and Chan , T. L. ( 1986 ). Cascade Impactor . American Industrial Hygiene Association (ISBN 0932627-24-2).
- May , K. R. ( 1966 ). Multistage Liquid Impinger . Bacteriological Rev. 30 : 559 – 570 .
- Mitchell , J. P. , Costa , P. A. , and Waters , S. ( 1988 ). An Assessment of an Andersen Mark-II Cascade Impactor . J. Aerosol Sci. 19 : 213 – 221 .
- Olsson , B. , and Lundbäck , H. ( 1991 ). A Multistage Liquid Impinger for Particle Size Fractionation of Inhalation Aerosols. Proceedings of Regulatory Issues in Aerosol Drug Development. College of Pharmacy , University of Kentucky.
- Olsson , B. , and Asking , L. ( 1994 ). A Model for the Effect of Inhalation Device Flow Resistance on the Peak Inspiratory Flow Rate and Its Application in Pharmaceutical Testing . J. Aerosols Med. 7 : 201 – 204 .
- Olsson , B. , Aiache , J-M. , Bull , H. , Ganderton , D. , Haywood , P. , Meakin , B. J. , Schorn , P. J. , and Wright , P. ( 1996 ). The Use of Inertial Impactors to Measure the Fine Particle Dose Generated by Inhalers . Pharmeuropa 8 : 291 – 298 .
- Petchey , C. R. F. , Booker , D. R. , and Marshall , I. A. ( 1995 ). The Calibration of the Astra Draco Multi-stage Liquid Impinger (MLI) . J. Aerosol Sci. 26 : 1324 .
- Ph. Eur. ( 1995 ). Preparations for Inhalation: Aerodynamic Assessment of Fine Particles. European Pharmacopeia , 2nd ed. Section V. 5.9.1 , Maisonneuve S. A ., Sainte Ruffine , France , pp. 8 – 15 .
- Zhengyong , L. , Aiwu , L. , and Cuiming , F. ( 1995 ). Experimental Verification of Using Cumulative Efficiency Curves for Determining Stage Constants of a Cascade Impactor . Aerosol Sci. Technol. 23 : 253 – 256 .