References
- BARTZOKIS G., ARAVAGIRI M., OLDENDORF W. H., MINTZ J. & MARDER A. R.: Field dependent transverse relaxation rate increase may be a specific measure of tissue iron stores. Magn. Reson. Med. 29 (1993), 459.
- BOTTOMLEY P A., FOSTER T. H., ARGERSINGER R. E. & PFEIFER L. M.: A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz. Dependence on tissue type, NMR frequency, tem-perature, species, excision and age. Med. Phys. 11 (1984), 425.
- BROOKS R. A., VYMAZAM J., BULTE J. W. M., BAUGARNER C. D. & TRAN V.: Comparison of T2 relaxation in blood, brain and ferritin. JMRI 4 (1995), 446.
- DIXON R. M. & STYLES P.: An assessment of spin echo rotating-frame imaging for spatially localized determi-nation of short T2 relaxation times in vivo. Magn. Reson. Med. 29 (1993), 110.
- DOUSSET V, GROSSMAN R. I., RAMER K. N. et al.: Experi-mental allergic encephalomyelitis and multiple sclerosis. Lesion characterization with magnetization transfer im-aging. Radiology 182 (1992), 483.
- FOLTZ W. D., STAINBY J. A. & WRIGHT G. A.: T2 accuracy on a whole-body imager. Magn. Reson. Med. 38 (1997), 759.
- GOMORI J. M., HOREV G., TAMARY H. et al.: Hepatic iron overload. Quantitative MR imaging. Radiology 179 (1991), 367.
- GOWLAND P A., LEACH M. 0. & TANNER S. F: Technical note. Reducing motion artefacts in in vivo magnetic reson-ance imaging measurements of relaxation times. Br. J. Radiol. 67 (1994), 1249.
- HARDY P. & HENKELMAN R. M.: Transverse relaxation rate enhancement caused by magnetic particles. Magn. Reson. Imaging 7 (1989), 265.
- KALTWASSER J. P, GOTTSCHALK R., SCHALK K. P & HARTL W: Non-invasive quantitation of liver iron-overload by magnetic resonance imaging. Br. J. Haematol. 74 (1990), 360.
- KURKI T., LUNDBOM N., Komu M. & KORMANO M.: Tissue characterization of intracranial tumors by magnetization transfer and spin-lattice relaxation parameters in vivo. JMRI 6 (1996), 573.
- Liu P, HENKELMAN M., JOSHI J. et al.: Quantification of cardiac and tissue iron by nuclear magnetic resonance re-laxometry in a novel murine thalassemia-cardiac iron over-load model. Can. J. Cardiol. 12 (1996), 155.
- LOESBERG A. C., KORMANO M. & LIPTON M. J.: Magnetiza-tion transfer imaging of normal and abnormal liver at 0.1 T. Invest. Radiol. 28 (1993), 726.
- PAPAKOSTANTINOU 0. G., MARTS T. G., KOSTARIDOU V. et al.: Assessment of liver iron overload by T2-quantitative magnetic resonance imaging. Correlation of T2-QMRI measurements with serum ferritin concentration and histo-logic grading of siderosis. Map. Reson. Imaging 13 (1995), 967.
- SALUSTRI C.: Lack of magnetization transfer from the fern-tin molecule. J. Magn. Reson. B 111 (1996), 171.
- STARK D. D., MOSELEY M. E., BACON B. R. et al.: Magnetic resonance imaging and spectroscopy of hepatic iron over-load. Radiology 192 (1994), 593.
- WOLFF S. D. & BALABAN R. S.: Magnetization transfer im-aging. Practical aspects and clinical applications. Radi-ology 192 (1994), 593.
- YE F. Q., MARTIN W. R. & ALLEN P S.: Estimation of brain iron in vivo by means of the interecho time dependence of image contrast. Magn. Reson. Med. 36 (1996), 153.