References
- Accuracy (trueness and precision) of measurement., International Standard ISO 5725-1:1994. Switzerland; 1998
- Clarke J. C., Black K., Rennie C., Amstutz H. C. Can wear in total hip arthroplasties be assessed from radiographs?. Clin Orthop Relat Res 1976; 121: 126–42
- Devane P. A., Bourne R. B., Rorabeck C. H., Hardie R. M., Horne J. G. Measurement of polyethylene wear in metal-backed acetabular cups. I. Three-dimensional technique. Clin Orthop Relat Res 1995; 319: 303–16
- Gorniak R. J. T., Kramer E. L., Maguire G. Q Jr., Noz M. E., Schettino C. J., Zeleznik M. P. Evaluation of a semi-automatic 3D fusion technique applied to molecular imaging and MRI brain/frame volume data sets. J Med Syst 2003; 27: 141–56 ISO
- Maguire G. Q Jr., Noz M. E., Rusinek H., Jaeger J., Kramer E. L., Sanger J. J., et al. Graphics applied to image registration. IEEE Computer Graphics Appl 1991; 11: 20–9
- Martell J. M., Berkson E., Berger R., Jacobs J. Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty. J Bone Joint Surg Am 2003; 85-A((6))1111–17
- Noz M. E., Maguire G. Q Jr., Zeleznik M. P., Kramer E. L., Mahmoud F., Crafoord J. A versatile functional-anatomic image fusion method for volume data sets. J Med Syst 2001; 25: 297–307
- Olivecrona H., Weidenhielm L., Olivecrona L., Beckman M. O., Stark A., Noz M. E., et al. A new CT method to measure cup orientation after total hip arthroplasty. A study on 10 patients. Acta Orthop Scand 2004; 75: 3 253–60
- Olivecrona L., Crafoord J., Olivecrona H., Noz M. E., Maguire G. Q Jr., Zeleznik M. P., et al. Acetabular component migration in total hip arthroplasty using CT and a semi-automated program for volume merging. Acta Radiol 2002; 43: 517–27
- Olivecrona L., Olivecrona H., Weidenhielm L., Noz M. E., Maguire G. Q Jr., Zeleznik M. P. Model studies on acetabular component migration in total hip arthroplasty using CT and a semi-automated program for volume merging. Acta Radiol 2003; 44: 419–29
- Ranstam J., Ryd L., Onsten I. Accurate accuracy assessment. Review of basic principles. Acta Orthop Scand 2000; 71: 106–8
- Schewelov T., Sanzen L., Borlin N., Markusson P., Onsten I. Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses: an experimental study. Acta Orthop Scand 2004; 75: 691–700
- Stulberg S. D., Wixson R. L., Adams A. D., Hendrix R. W., Bernfield J. B. Monitoring pelvic osteolysis following total hip replacement surgery: an algorithm for surveillance. J Bone Joint Surg Am 2002; 84-A(Suppl 2)116–22