208
Views
2
CrossRef citations to date
0
Altmetric
Original Article

64-slice Computed Tomography Assessment of Coronary Artery Stents: a Phantom Study

, , , , , , & show all
Pages 36-42 | Accepted 15 Sep 2005, Published online: 09 Jul 2009

References

  • Anonymous. Heart disease and stroke statistics – 2004 update. American Heart Association, Dallas 2003
  • Antoniucci D., Valenti R., Santoro G. M., Bolognese L., Trapani M., Cerisano G., et al. Restenosis after coronary stenting in current clinical practice. Am Heart J 1998; 135: 510–18
  • Buckwalter K., Rydberg J., Rankin J. Parameters affecting isotropic visualization with 4, 16, and 40 slice multi-channel CT scanners: relevance to small joint imaging. Radiology 2004; 233: S200
  • Buecker A., Spuentrup E., Ruebben A., Guenther R. W. Artifact-free in-stent lumen visualization by standard magnetic resonance angiography using a new metallic magnetic resonance imaging stent. Circulation 2002; 105: 1772–5
  • Fattori R., Piva T. Drug-eluting stents in vascular intervention. Lancet 2003; 361: 247–9
  • Flohr T., Bruder H., Stierstorfer K., Simon J., Schaller S., Ohnesorge B. New technical developments in multislice CT. Part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging. Rofo 2002; 174: 1022–7
  • Grube E., Silber S., Hauptmann K. E., Mueller R., Buellesfeld L., Gerckens U., et al. TAXUS I: six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions. Circulation 2003; 107: 38–42
  • Knollmann F. D., Moller J., Gebert A., Bethge C., Felix R. Assessment of coronary artery stent patency by electron-beam CT. Eur Radiol 2004; 14: 1341–7
  • Kruger S., Mahnken A. H., Sinha A. M., Borghans A., Dedden K., Hoffmann R., et al. Multislice spiral computed tomography for the detection of coronary stent restenosis and patency. Int J Cardiol 2003; 89: 167–72
  • Maintz D., Botnar R. M., Fischbach R., Heindel W., Manning W. J., Stuber M. Coronary magnetic resonance angiography for assessment of the stent lumen: a phantom study. J Cardiovasc Magn Reson 2002; 4: 359–67
  • Maintz D., Juergens K. U., Wichter T., Grude M., Heindel W., Fischbach R. Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation. Eur Radiol 2003; 13: 830–5
  • Maintz D., Grude M., Fallenberg E. M., Heindel W., Fischbach R. Assessment of coronary arterial stents by multislice-CT angiography. Acta Radiol 2003; 44: 597–603
  • Mahnken A. H., Buecker A., Wildberger J. E., Ruebben A., Stanzel S., Vogt F., et al. Coronary artery stents in mutislice computed tomography: in vitro artifact evaluation. Invest Radiol 2004; 39: 27–33
  • Mahnken A. H., Seyfarth T., Flohr T., Herzog C., Stahl J., Stanzel S., et al. Flat-panel detector computed tomography for the assessment of coronary artery stents: phantom study in comparison with 16-slice spiral computed tomography. Invest Radiol 2005; 40: 8–13
  • Mollet N. R., Cademartiri F., Nieman K., Saia F., Lemos P. A., McFadden E. P., et al. Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris. J Am Coll Cardiol 2004; 43: 2265–70
  • Pump H., Mohlenkamp S., Sehnert C. A., Schimpf S. S., Schmidt A., Erbel R., et al. Coronary arterial stent patency: assessment with electron-beam CT. Radiology 2000; 214: 447–52
  • Regar E., Serruys P. W., Bode C., Holubarsch C., Guermonprez J. L., Wijns W., et al. Angiographic findings of the multicenter randomized study with the sirolimus-eluting Bx Velocity balloon-expandable stent (RAVEL): sirolimus-eluting stents inhibit restenosis irrespective of the vessel size. Circulation 2002; 106: 1949–56
  • Ropers D., Baum U., Pohle K., Anders K., Ulzheimer S., Ohnesorge B., et al. Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 2003; 107: 664–6
  • Schuijf J. D., Bax J. J., Jukema J. W., Lamb H. J., Warda H. M., Vliegen H. W., et al. Feasibility of assessment of coronary stent patency using 16-slice computed tomography. Am J Cardiol 2004; 94: 427–30
  • Willoteaux S., Negawi Z., Lions C., Gaxotte V., Beregi J. P. Observations from multidetector CT imaging of different types of renal artery stents. J Endovasc Ther 2004; 11: 560–9
  • Flohr T., Stierstorfer K., Raupach R., Ulzheimer S., Bruder H. Performance evaluation of a 64-slice CT system with z-flying focal spot. Rofo 2004; 176: 1803–10

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.