References
- Sardanelli F, Zandrino F, Parodi RC, De Caro G. MR angiography of internal carotid arteries: breath-hold Gd-enhanced 3D fast imaging with steady-state precession versus unenhanced 2D and 3D time-of-flight techniques. J Comput Assist Tomogr 1999; 23: 208–15
- Snidow JJ, Aisen AM, Harris VJ, Trerotola SO, Johnson MS, Sawchuk AP, et al. Iliac artery MR angiography: comparison of three-dimensional gadolinium-enhanced and two-dimensional time-of-flight techniques. Radiology 1995; 196: 371–8
- Wikstrom J, Wasser MN, Pattynama PM, Bonomo L, Hamm B, Del Maschio A, et al. Gadobenate dimeglumine-enhanced magnetic resonance angiography of the pelvic arteries. Invest Radiol 2003; 38: 504–15
- Vosshenrich R, Kopka L, Castillo E, Bottcher U, Graessner J, Grabbe E. Electrocardiograph-triggered two-dimensional time-of-flight versus optimized contrast-enhanced three-dimensional MR angiography of the peripheral arteries. Magn Reson Imaging 1998; 16: 887–92
- High WA, Ayers RA, Chandler J, Zito G, Cowper SE. Gadolinium is detectable within the tissue of patients with nephrogenic systemic fibrosis. J Am Acad Dermatol 2007; 56: 21–6
- Thomsen HS, Morcos SK, Dawson P. Is there a causal relation between the administration of gadolinium based contrast media and the development of nephrogenic systemic fibrosis (NSF)?. Clin Radiol 2006; 61: 905–6
- Oshinski JN, Ku DN, Pettigrew RI. Turbulent fluctuation velocity: the most significant determinant of signal loss in stenotic vessels. Magn Reson Med 1995; 33: 193–9
- Furst G, Hofer M, Sitzer M, Kahn T, Muller E, Modder U. Factors influencing flow-induced signal loss in MR angiography: an in vitro study. J Comput Assist Tomogr 1995; 19: 692–9
- Meaney JF. Magnetic resonance angiography of the peripheral arteries: current status. Eur Radiol 2003; 13: 836–52
- Maki JH, Prince MR, Chenevert TC. Optimizing three-dimensional gadolinium-enhanced magnetic resonance angiography. Original investigation. Invest Radiol 1998; 33: 528–37
- Gatenby JC, McCauley TR, Gore JC. Mechanisms of signal loss in magnetic resonance imaging of stenoses. Med Phys 1993; 20: 1049–57
- Mustert BR, Williams DM, Prince MR. In vitro model of arterial stenosis: correlation of MR signal dephasing and trans-stenotic pressure gradients. Magn Reson Imaging 1998; 16: 301–10
- Sebok NR, Sebok DA, Wilkerson D, Mezrich RS, Zatina M. In-vitro assessment of the behavior of magnetic resonance angiography in the presence of constrictions. Invest Radiol 1993; 28: 604–10
- Westenberg JJ, van der Geest RJ, Wasser MN, Doornbos J, Pattynama PM, de Roos A, et al. Objective stenosis quantification from post-stenotic signal loss in phase-contrast magnetic resonance angiographic datasets of flow phantoms and renal arteries. Magn Reson Imaging 1998; 16: 249–60