2,443
Views
22
CrossRef citations to date
0
Altmetric
Original Article

Medical reference dosimetry using EPR measurements of alanine: Development of an improved method for clinical dose levels.

, , &
Pages 216-222 | Received 25 May 2008, Published online: 08 Jul 2009

References

  • Chetty IJ, Curran B, Cygler JE, DeMarco JJ, Ezzell G, Faddegon BA, et al. Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning. Med Phys 2007; 34: 4818–53
  • Sharpe PHG, Rajendran K, Sephton JP. Progress towards an alanine/ESR therapy level reference dosimetry service at NPL. Appl Radiat Isot 1996; 47: 1171–5
  • Proceedings of the 216th PTB Seminar. Alanine Dosimetry for clinical applications. May 8th–9th 2006. Physikalisch-Technische Bundesanstalt, Seminarzentrum Kohlrausch-Bau, Bundesallee 100, 38116, Braunschweig, Germany.
  • Anton M. Development of a secondary standard for the absorbed dose to water based on the alanine EPR dosimetry system. Appl Radiat Isot 2005; 62: 779–95
  • Bradshaw WW, Cadena DG, Crawford GW, Spetzler HAW. The use of alanine as a solid dosimeter. Radiat Res 1962; 17: 11–21
  • Regulla DF, Deffner U. Dosimetry by ESR spectroscopy of Alanine. Int J Appl Radiat Isot 1982; 33: 1101–14
  • American Society for Testing and Materials ASTM. Standard practice for use of the Alanine-EPR dosimetry system, 1999. ASTM E1607–9, June.
  • McEwen MR, Niven D. Characterization of Virtual Water™ for dosimetry. Med Phys 2006; 33: 876–87
  • Anton M, Kapsch R-P, Krystek M, Renner F. Response of the alanine/ESR dosimetry system to MV x-rays relative to 60Co radiation. Phys Med Biol 2008; 53: 2753–70
  • Sharpe PHG. Progress report on radiation dosimetry at NPL, BIPM report CCRI(I)-03-14 (Sèvres).
  • Zeng GG, McEwen MR, Rogers DWO, Klassen NV. An experimental and Monte Carlo investigation of the energy dependence of alanine/EPR dosimetry: I. Clinical x-ray beams. Phys Med Biol 2004; 49: 257–70
  • Sharpe PHG, Sephton JP. Therapy level alanine dosimetry at the NPL. In: Proceedings of the 216th PTB Seminar, Alanine Dosimetry for clinical applications, 2006, PTB, Braunschweig, Germany.
  • Olsen KJ, Hansen JW, Wille M. Response of the alanine radiation dosimeter to high-energy photon and electron beams. Phys Med Biol 1990; 35: 43–52
  • IAEA TRS-398. Absorbed dose determination in external beam radiotherapy: An International Code of Practice for Dosimetry based on standards of absorbed dose to water. International Atomic Energy Agency, Vienna, 2000, ISSN 1011-4289.
  • Ramani R, Kohli K, Cao F, Heaton R. Dosimetric evaluation of Plastic Water Diagnostic Therapy. J Appl Clin Med Phys 2008; 9: 98–111
  • BJR Supplement 25. Central axis depth dose data for use in radiotherapy: 1996. Published by the British Institute of Radiology.
  • Østerås BH, Hole EO, Olsen DR, Malinen E. EPR dosimetry of radiotherapy photon beams in inhomogeneous media using alanine films. Phys Med Biol 2006; 51: 6315–28
  • Kuntz F, Pabst JY, Delpech JP, Wagner JP, Marchioni E. Alanine-ESR In Vivo dosimetry: A feasibility study and possible applications. Appl Radiat Isot 1996; 47: 1183–8
  • Feist H, Regulla D, Wieser A. Is Alanine/ESR dosimetry now an alternative to ferrous sulphate dosimetry?. Appl Radiat Isot 1993; 44: 47–51
  • Gustafsson H. Development of sensitive EPR dosimetry methods. Linköping University Medical Dissertations, No. 1044, 2008. Division of Radiation Physics, Department of Medical and Health Sciences, Faculty of Health Sciences, Linköping University, SE-58185 Linköping, Sweden.
  • Lund E, Gustafsson H, Danilczuk M, Sastry MD, Lund A, Vestad TA, et al. Formates and dithionates: Sensitive EPR-dosimeter materials for radiation therapy. Appl Radiat Isot 2005; 62: 317–24
  • Olsen KJ, Hansen JW, Waligórski MPR. ESR Dosimetry in calibration intercomparisons with high-energy photons and electrons. Appl Radiat Isot 1989; 40: 985–8
  • Bassler N, Hansen JW, Palmans H, Holzscheiter MH, Kovacevic S, the AD-4/ACE Collaboration. The antiproton depth-dose curve measured with alanine detectors. Nucl Instr Meth Phys Res B 2008;266:929–36.
  • Arber JM, Sharpe PHG. Fading characteristics of irradiated alanine pellets: The importance of pre-irradiation conditioning. Appl Radiat Isot 1993; 44: 19–22

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.