References
- Liu L, Tang J, Peng H, et al. A long-term, prospective, cohort study on the performance of right ventricular pacing leads: comparison of active-fixation with passive-fixation leads. Sci Rep 2015;5:7662
- Rajappan K. Permanent pacemaker implantation technique: part II. Heart 2009;95:334-42
- Fahy GJ, Kleman JM, Wilkoff BL, et al. Low incidence of lead related complications associated with nonthoracotomy implantable cardioverter defibrillator systems. Pacing Clin Electrophysiol 1995;18(1 Pt 2):172-8
- Sadamatsu K. Complication of Pacemaker Implantation: An Atrial Lead Perforation. Available at: http://cdn.intechopen.com/pdfs-wm/13788.pdf [Last accessed 12 February 2016]
- Cano O, Osca J, Sancho-Tello MJ, et al. Failure of the active-fixation mechanism during removal of active-fixation pacing leads. Pacing Clin Electrophysiol 2011;34:1217-24
- Niazi I, Bajwa T, Sra J, Akhtar M. A review of innovative strategies for CRT implantation: part II – coronary venous stenting. J Innov Card Rhythm Manag 2011;2:159-64
- Das MR (ed.) Modern Pacemakers – Present and Future. Common Pacemaker Problems: Lead and Pocket Complications. Enes Elvin Gul and Mehmet Kayrak, 2011:300-18 http://cdn.intechweb.org/pdfs/13786.pdf
- Guo GBF. “What & How” About Implantation of AAI/R, DDD/R, and VVI/R Pacemakers. Acta Cardiol Sin 2005;21(Suppl II):9-17
- Connelly DT, Steinhaus DM, Handlin L, et al. Atrial pacing leads following open heart surgery: active or passive fixation? Pacing Clin Electrophysiol 1997;20(10 Pt 1):2429-33
- DeCaprio V, Hurzeler P, Furman S. Comparison of unipolar and bipolar electrograms for cardiac pacemaker. Circulation 1977;56:750-5
- Myers GH, Kresh YM, Parsonnet V. Characteristics of intracardiac electrograms. Pacing Clin Electrophysiol 1978;1:90-103
- Furman S. Sensing and timing the cardiac electrogram. Hayes DL (Ed.) A Practice of Cardiac Pacing, 3rd edn. Mount Kisco, NY: Futura Publishing Company, 1993;89-132
- Parsonnet V, Bilitch M, Furman S, et al. Early malfunction of transvenous pacemaker electrodes: a three-center study. Circulation 1979;60:590-6
- Witt CM, Lenz CJ, Shih HH, et al. Right atrial lead fixation type and lead position are associated with significant variation in complications. J Interv Card Electrophysiol 2016;47:313-319
- Levy T, Walker S, Rex S, Paul V. A comparison between passive and active fixation leads in the coronary sinus for biatrial pacing: initial experience. Europace 2000;2:228-32
- Fuertes B, Toquero J, Arroyo-Espliguero R, Lozano IF. Pacemaker lead displacement: mechanisms and management. Indian Pacing Electrophysiol J 2003;3:231-8
- Sterlinski M, Przybylski A, Maciag A, et al. Subacute cardiac perforations associated with active fixation leads. Europace 2009;11:206-12
- Hai-Bo Y, Yan-Chun L, Guo-Qing X, et al. The comparison between the active-fixation leads and passive-fixation leads in right ventricular apical pacing. Heart 2016;99:A8-9
- Kistler PM, Kalman JM, Fynn SP, et al. Rapid decline in acute stimulation thresholds with steroid-eluting active-fixation pacing leads. Pacing Clin Electrophysiol 2005;28:903-9
- Kistler PM, Liew G, Mond HG. Long-term performance of active-fixation pacing leads: a prospective study. Pacing Clin Electrophysiol 2006;29:226-30
- Bracke F. Complications and lead extraction in cardiac pacing and defibrillation. Netherlands Heart J 2008;16(Suppl 1):S28-S31
- Cohen MI, Bush DM, Vetter VL, et al. Permanent epicardial pacing in pediatric patients: seventeen years of experience and 1200 outpatient visits. Circulation 2001;103:2585-90
- Kubus P, Materna O, Gebauer RA, et al. Permanent epicardial pacing in children: long-term results and factors modifying outcome. Europace 2012;14:509-14
- Cano Ó, Andrés A, Alonso P, et al. Incidence and predictors of clinically relevant cardiac perforation associated with systematic implantation of active-fixation pacing and defibrillation leads: a single-centre experience with over 3800 implanted leads. Europace 2016;pii: euv410. [Epub ahead of print], doi: 10.1093/europace/euv410
- Sterlinski M, Przybylski A, Maciag A, et al. Subacute cardiac perforations associated with active fixation leads. Europace 2009;11:206-12
- Avcı A, Demir K, Altunkeser BB. [Right atrial perforation after an endocardial screw-in atrial lead implantation]. Turk Kardiyol Dern Ars 2013;41:541-4
- Lin YS, Chen TH, Hung SP, et al. Impact of pacemaker lead characteristics on pacemaker related infection and heart perforation: a nationwide population-based cohort study. PLoS One 2015;10:e0128320
- Piot O, Deballon R, Nitu D, et al. Factors predicting Sprint Fidelis lead fracture: results at 5 years from a French multicentre registry. Arch Cardiovasc Dis 2015;108:220-6