7
Views
4
CrossRef citations to date
0
Altmetric
Research Article

Automatic adjustment of biphasic pulse duration in transthoracic defibrillation

Pages 210-214 | Published online: 09 Jul 2009

References

  • BARDY, G. H., MARCHLINSKI, F. E., SHARMA, A D., WORLEY, S. J., LucERI, R M., YEE, R., HALPERIN, B. D., FELLOWS, C. L, AHERN, T. S., CHILSON, D. A, PACKER, D. L, WLBER, D. J., MATTIONI, T. A., REDDY, R, KRoNmAL, R A, and LAZARRA, L, 1996, Multicenter comparison of truncated biphasic shocks and standard damped sine wave monophasic shocks for transthoracic defibrillation. Circulation, 94, 2507–2514.
  • CANSELL, A, 1997, Efficacite et securite des formes d'ondes des impulsions de defibrillation cardiaque transthoracique. La Revue des SAMU, 5, 229–237.
  • CLELAND, B. G., 1996, A conceptual basis for defibrillation waveforms. Pacing and Clinical Electrophysiology, 19, 1186–1195.
  • KROLL, M W, 1994, A minimal model of the single capacitor biphasic defibrillation waveform. Pacing and Clinical Electrophysiology, 17, 1782–1792.
  • KROLL, M W, and BREWER, J. E., 1997, Automated external defibrillators: design considerations. New Horizons, 5, 128 — 136.
  • SWERDLOW, C. D., BREWER, J. E., KAss, R M, and KRoLL, M W, 1997, Application of models of defibrillation to human defibrillation data. Implications for optimising implantable defibrillator capacitance. Circulation, 96, 2813 —2822.
  • YAMANOUSHI, Y, BREWER, J. E., MOWREY, K. A, DONOHOO, M, WLKOFF, B. L., and TCHOU, P., 1998, Optimal small capacitor biphasic waveform for external defibrillation. Circulation, 22, 2487–2499.
  • SWERDLOW, C. D., FAN, W, and BREWER, J. E., 1996, Charge-burping theory correctly predicts optimal ratios of phase duration for biphasic defibrillation waveforms. Circulation, 94, 2278–2284.
  • YAMANOUSHI, Y, MOWREY, K. A, NAZDAM, G. R, HILLS, D. G., KRoLL, M W, BREWER, J. E., DONOHOO, M S., VOLKOFF, B. L., and TCHOU, P., 1996, Large change in voltage at phase reversal improves biphasic defibrillation thresholds. Parallel-series mode switching. Circulation, 94, 1768–1773.
  • COOPE RR. A S., WALLENIUS, S. T., SMITH, W M, and IDEKER, R. E., 1993, The effect of phase separation on biphasic waveform defibrillation. Pacing and Clinical Electrophysiology, 16, 471–482.
  • GLINER, B. E., CAMERON, D., COLE, C. S., LYSTER, T. D., POWERS, D. J., and MORGAN, C. B., 1998, Electrotherapy method and apparatus for external defibrillation. US Patent No. 5593427.
  • IDEKER, R E., TANG, A S. L., FRAZIER, D. W, SHIBATA, N., CHEN, P.-S., and WHARTON, J. M, 1991, Ventricular defibrillation: basic concepts. Cardiac Pacing and Electra-physiology edited by N. El Sherif and P. Samet (Orlando, USA Saunders), pp. 713–726.
  • SWEENEY, R. J., GILL, R M, and REID, P. R., 1991, Characterization of refractory period extension by transcardiac shocks. Circulation, 83, 2057–2066.
  • GEDDES, L. A, 1994, Electrodes for transchest and ICD defibrillation and multifiinctional electrodes. Defibrillation of the Heart ICDs, AMs and Manual, edited by W. A Tacker Jr (St Louis, USA Mosby-Year Book Inc.), pp. 82–118.
  • AL HATIB, F., TRENDAFILOV4 E., and DASICALOV, I., 2000, Transthoracic electrical impedance during external defi-brillation: comparison of measured and modelled waveforms. Physiological Measurement, 21, 145–153.
  • KRASTEVA, V., CANSELL, A, and DASICALOV, I., 2000, Modelling transthoracic defibrillation waveforms. Journal of Medical Engineering and Technology, 24, 63 —67.
  • GEDDES, L. A, TACKER, W A, SCHOENLEIN, B. S., MINTON, M, GRUBBS, S., and WLCOX, P., 1976, The prediction of the impedance of the thorax to defibrillating current. Medical Instrumentation, 10, 159–162.
  • KERBER, R. E., KOUBA, C., MARTINS, J., KELLY, K, Low, R, HOYT, R., FERGUSON, D., BAILEY, L, BENNETT, P., and CHARBONNIER, F., 1984, Advance prediction of transthoracic impedance in human defibrillation and cardioversion: importance of impedance in determining the success of lowenergy shocks. Circulation, 70, 303–308.
  • AYATI, S., and LOPIN, M, 1997, Electrotherapy current waveform. International Patent No. 98/26841.
  • DAL7FI L, G. W N., CUNNINGHAM, S. R., ANDERSON, J., and ADGEY, A A J., 1989, Initial experience with microprocessor controlled current based defibrillator. British Heart Journal, 61, 502–505.
  • ZIMMERMAN, D., FARICIIANI, F., and WESLEY, R C., 1994, Automated precision current delivery an alternative method for cardiac defibrillation. Pacing and Clinical Electrophysiology, 17, 222–239.
  • KERBER, R. E., KIESO, R A, KIENZLE, M G., OLSHANSKY, B., WALDO, A L., CARLSON, M D., WLBER, D. J., ASCHOFF, A M, BIRGER, S., and CHARBONNIER, F., 1996, Current-based transthoracic defibrillation. American Journal of Cardiology, 78, 1113–1118.
  • KERBER, R. E., MARTINs, J. B., KIENZLE, M G., CONSTAI\ITIN, L, OLCHGANSKY, B., HOPSON, R., and CHARBONNIER, F., 1998, Energy, current, and success in defibrillation and cardioversion: clinical studies using an automated impedance-based method of energy adjustment. Circulation, 77, 1038–1046.
  • SWEENEY, R. J., GILL, R. M and REID, P. R., 1996, Post-shock spatial gradients of transmembrane potential as a source for post-shock activation during failed defibrillation. Computers in Cardiology, 23, 353–356.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.