45
Views
5
CrossRef citations to date
0
Altmetric
Research Article

An instrumented object for evaluation of lateral hand grasp during functional tasks

Pages 207-211 | Published online: 09 Jul 2009

  • BUCKETT, J. R., PECKHAM, P. H., THROPE, G. B., BRASWEll, S. D., and KEITH, M. W., 1988, A flexible, portable system for neuromuscular stimulation in the paralyzed upper extremity. IEEE Transactions an Biomedical Engineering 35, 897904.
  • HANDA, Y., OHKUBO, K., and HOSHIMIYA, N., 1989, A portable multi-channel FES system for restoration of motor function of the paralyzed extremities. Automedica, 11, 221-231.
  • NATHAN, R. H., and OHRY, A., 1990, Upper limb functions regained in quadriplegia: a hybrid computerized neuromuscular stimulation system. Archives of Physical Medicine and Rehabilitation, 71, 415-421.
  • PROCHAZKA, A., GAUTHIER, M., WIELER, M., and KANWELL, Z., 1997, The bionic glove: an electrical stimulator garment that provides controlled grasp and hand opening in quadriplegia. Archives of Physical Medicine and Rehabilitation, 78, 608-614.
  • WIJMAN, C. A., STROH, K. C., VAN DOREN, C. L., THROPE, G. B., PECKHAM, P. H., and KEITH, M. W., 1990, Functional evaluation of quadriplegic patients using a hand neuroprosthesis. Archives of Physical Medicine and Rehabilitation, 71, 1053-1057.
  • HAUGLAND, M., LICKEI, A., HAASE, J., and SINKJá R, T., 1999, Control of FES thumb forces using slip information obtained from cutaneous electroneurogram in quadriplegic man. IEEE Transactions on Rehabilitation Engineering 7, 215-227.
  • INMANN, A., HAUGLAND, M., and SINKJá R, T., 2000, Application of grasp force during eating: comparison of healthy subjects with tetraplegics using a hand grasp neuroprosthesis incorporating natural sensory feedback. CD-ROM Proceedings of the 22nd Annual International Conference of IEEE/EMBS, July 23-28, Chicago, USA.
  • AN, K. N., CHAO, E. Y., and ASKEW, L. J., 1980, Hand strength measurement instruments. Archives of Physical Medicine and Rehabilitation, 61, 366-368.
  • PRONK, C. N., and NIESING, R., 1981, Measuring hand-grip force, using a new application of strain gauges. Medical Biological Engineering Computing, 19, 127-128.
  • SOLGAARD, S., KRISTIANSEN, B., and JENSEN, J. S., 1984, Evaluation of instruments for measuring grip strength. Acta Orthopaedica Scandinavica, 55, 569-572.
  • HEILIWELL, P., HOWE, A., and WRIGHT, V., 1987, Functional assessment of the hand: reproducibility, acceptability, and utility of a new system for measuring strength. Annals of the Rheumatic Diseases, 46, 203-208.
  • TCHENG, P., and ELLIOT, J., 1987, Hand-strength meter. NASA Tech Briefs, 4, 59.
  • KING, J. W., and BERRYHILL, B. H., 1988, A comparison of two static grip testing methods and its clinical applications: a preliminary study. Journal of Hand Therapy, 4, 204-208.
  • HERMSDORFER, J., MAI, N., and MARQUARDT, C., 1992, Evaluation of precision grip using pneumatically controlled loads. Journal of Neuroscience Methods, 45, 117-126.
  • RADHAKRISHNAN, S., and NAGARAVINDRA, M., 1993, Analysis of hand forces in health and disease during maximum isometric grasping of cylinders. Medical Biological Engineering Computing, 31, 372-376.
  • MEMBERG, W. D., and CRAGO, P. E., 1995, A grasp force and position sensor for the quantitative evaluation of neuroprosthetic hand grasp systems. IEEE Transactions on Rehabilitation Engineering, 3, 175-181.
  • RICHARDS, L., and PALMITER-THOMAS, P., 1996, Grip strength measurement: a critical review of tools, methods and clinical utility. Critical Reviews in Physical and Rehabilitation Medicine, 8, 87-109.
  • MEMBERG, W. D., and CRAGO, P. E., 1997, Instrumented objects for quantitative evaluation of hand grasp. Journal of Rehabilitation Research and Development, 34, 82-90.
  • CASTRO, M. C. F., and CLIQUET, A. Jr., 1997, A low-cost instrumented glove for monitoring forces during object manipulation. IEEE Transactions on Rehabilitation Engineering, 5, 140-147.
  • KILGORE, K. L., PECKHAM, P. H., THROPE, G. B., KEITH, M. W., and GALLAHER-STONE, K. A., 1989, Synthesis of hand grasp using functional neuromuscular stimulation. IEEE Transactions on Biomedical Engineering, 36, 761-770.
  • HINES, A. E., OWENS, N. E., and CRAGO, P. E., 1992, Assessment of input-output properties and control of neuroprosthetic hand grasp. IEEE Transactions on Biomedical Engineering, 39, 610-623.
  • CRAGO, P. E., CHIZECK, H. J., NEUMAN, M. R., and HAMBRECHT, F. T., 1986, Sensors for use with functional neuromuscular stimulation. IEEE Transactions on Biomedical Engineering, 33, 256-268.
  • HOFFMANN, K., 1989, An introduction to measurements using strain gages (Darmstadt, Germany: Hottinger Baldwin Messtechnik GmbH)
  • PERRY, C. C., and LISSNER, H. R., 1962, The strain gage primer (New York: McGraw-Hill Book Company)

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.