2,913
Views
415
CrossRef citations to date
0
Altmetric
Research Article

Electrical impedance tomography (EIT): a review

Pages 97-108 | Published online: 09 Jul 2009

  • HENDERSON, R. P., and WEBSTER, J. G., 1978, An impedance camera for spatially specific measurements of the thorax. JFKF. Transactions on Biomedical Engineering, 25, 250-254.
  • BARBER, D. C., BROWN, B. H., and FREESTON, I. L., 1983, Imaging spatial distributions of resistivity using applied potential tomography. Electronics Letters, 19, 93-95.
  • BROWN, B. H., 1983, Tissue impedance methods. Imaging with Non-ionising Radiations edited by D. F. Jackson (Guilford: Surrey University Press).
  • BARBER, D. C., and BROWN, B. H., 1984, Applied potential tomography. Journal of Physics E: Scientific Instruments, 17, 723-733.
  • SEACAR, A. D., BARBER, D. C., and BROWN, B. H., 1987, Electrical impedance imaging. IEE Proceedings, Part A, No. 2, pp. 201-210.
  • BROWN, B. H., BARBER, D. C., and TARRASENKO, L.DS), 1987, Clinical Physics & Physiological Measurement, S (Suppl. A), ISOpp (special issue on Electrical Impedance Tomography-applied potential tomography).
  • BROWN, B. H., BARBER, D. C., and JOSSINET, J.DS), 1988, Clinical Physics & Physiological Measurement, 9 (Suppl. A), 147pp (special issue on Electrical Impedance Tomography-applied potential tomography).
  • BROWN, B. H., and BARBER, D. C. (eds), 1992, Clinical Physics & Physiological Measurement, 13 (Suppl. A), 207pp (special issue on Electrical Impedance Tomography).
  • BARBER, D. C., and BROWN, B. H.DS), 1994, Physiological Measurement, 15 (Suppl. A), 224pp (special issue on Electrical Impedance Tomography).
  • BARBER, D. C., and BROWN, B. H. (eds), 1995, Physiological Measurement, 16 (Suppl. 3A), 266pp (special issue on Electrical Impedance Tomography).
  • BOONE, K., BARBER, D., and BROWN, B., 1997, Review, imaging with electricity, report of the European Concerted Action on impedance tomography. Journal of Medical Engineering and Technology, 21, 201-232.
  • SCHWAN, H. P., 1999, The practical success of impedance techniques from an historical perspective. Annals of the New York Academy of Science, 83, 1-12.
  • SCHWAN, H. P., 1963, Detection of biological impedances. Physiological Techniques in Biological Research, Vol. 6 (New York: Academic Press), pp. 323-406.
  • DUCK, F. A., 1990, Physical Properties of Tissue (New York, London: Academic Press).
  • GEDDES, L., and BAKER, L. E., 1967, The specific resistance of biological materials: a compendium of data for the biomedical engineer and physiologist Medical & Biological Engineering, 5, 271-93.
  • FOSTER, K. R., and SCHWAN, H. P., 1989, Dielectric properties of tissues and biological materials-a critical review. Critical Reviews in Biomedical Engineering, 17, 25-104.
  • QERSING, E., 1999, Monitoring temperature induced changes in tissue during hyperthermia by impedance methods. Annals of the New York Academy of Science, 83, 1320.
  • WANG, W. Q., and YORK, T. A., 1999, New AC-based capacitance tomography system. IEE Proceedings, Scientific Measurement and Technology, 146, 47-53.
  • GRIFTTTHS, H., STEWART, W. R-, and GOUGH, W., 1999, Magnetic induction tomography: a measurement system for biological tissue. Annals of the New York Academy of Science, 873, 335-345.
  • KORJENEVSKY, A., CHEREPENIN, V., and SAPETSKY, A., 2000, 'Magnetic induction tomography': experimental realisation. Physiological Measurement, 21, 89-94.
  • McCANN, H., YANG, W. Q., and POLYDORIDES, N. P., 1999, Information retrieval by electrical capacitance tomography, evaluation of an alternative algorithm and the importance of boundary conditions. 1st World Congress on Industrial Process Tomography, (Buxton, UK), April 14-17, ISBN 085316 193 3, pp. 206-210.
  • YORK, T., 2001, Status of electrical tomography in industrial applications. Journal of Electronic Imaging, 20, 608-619.
  • BROWN, B. H., 2001, Medical impedance tomography and process impedance tomography, a brief review. Measurement Science and Technology, 12, 991-996.
  • WILSON, A. J., MILNES, P., WATERWORTH, A. R., and BROWN, B. H., 2001, Mk3.5 a modular, multi-frequency successor to the MkSa EIS/EIT system. Physiological Measurement, 22, 4954.
  • NEWELL, J. C., ISAACSON, D., CHENEY, M., SAULNIER, G. J., GISSER, D., GOBLE, G., COOK, R. D., EDIC, P. M., and NEWTON, A. M., 1993, In vivo impedance images using sinusoidal current patterns. Clinical and Physiological Applications of Electrical Impedance Tomography, edited by D. S. Holder (London: UCL Press).
  • ISAACSON, D., 1986, Distinguishability of conductivities by electric current computed tomography. JKFK Transactions on Medical Imaging, 5, 91-95.
  • BROWN, B. H., BARBER, D. C., LEATHARD, A. D., Lu, L., WANG, W., SMALLWOOD, R. H., and WILSON, A. J., 1994, High frequency EIT data collection and parametric imaging. Innovation et Technologie en Biologie et Medicine, 15, 1-9.
  • BROWN, B. H., TIDY, J., BOSTON, K., BLACKETT, A. D., SMALLWOOD, R. H., and SHARP, F., 2000, The relationship between tissue structure and imposed electrical current flow in cervical neoplasia. The Lancet, 355, 892-895.
  • COLE, K. S., and COLE, R. H., 1941, Dispersion and absorption in dielectrics. Journal of Chemical Physics, 9, 341-351.
  • WATERWORTH, A. R., 2000, Data analysis techniques of measured biological impedance. PhD thesis, University of Sheffield, UK.
  • BARBER, D. C., 1993, An overview of image reconstruction. Clinical and Physiological Applications of Electrical Impedance Tomography, edited by D. S. Holder (London: UCL Press).
  • MUELLER, J. L., SILTANEN, S., and ISAACSON, D., 2002, A direct reconstruction algorithm for electrical impedance tomography. TRRF. Transactions on Medical Imaging, 6, 555-559.
  • BORCEA, L., BERRYMAN, J. G., and PAPANICOLAOU, 1996, High contrast impedance tomography. Inverse Probability, 12, 835-859.
  • DOBSON, D. C., and SANTOSA, F., 1994, An image enhancement technique for electrical impedance tomography. Inverse Probability, 10, 317-334.
  • AVILL, R., MANGNALL, Y. F., BIRD, N. C., BROWN, B. H., BARBER, D. C., SEAGAR, A. D., JOHNSON, A. G., and READ, N. W., 1987, Applied potential tomography, a new non invasive technique for measuring gastric emptying. Gastroenterology, 92, 1019-1026.
  • Commentary, 1987, Electrical resistance can follow soup and potato. New Scientist, 42 (June)> 25.
  • EVANS, D. F., and WRIGHT, J. W., 1990, Is acid suppression necessary when measuring gastric emptying using applied potential tomography? Proceedings of the Copenhagen Meeting on Electrical Impedance Tomography, edited by T. J. Hames (Sheffield: Sheffield University) pp. 249-255.
  • MANGNALL, Y. F., BAXTER, A. J., AVILL, R., BIRD, N. C., BROWN, B. H., BARBER, D. C., SEAGAR, A. D., JOHNSON, A. G., and READ, N. W., 1987, Applied potential tomography, a new technique for assessing gastric function. Clinical Physics & Physiological Measurement, 8 (Suppl. A), 131-140.
  • MANGNALL, Y. F., BARNISH, C., BROWN, B. H., BARBER, D. C., JOHNSON, A. G., and READ, N. W., 1988, Comparison of applied potential tomography and impedance epigastrography as methods of measuring gastric emptying. CPPM, 9, 249-254.
  • DEVANE, S. P., 1993, Application of EIT to gastric emptying in infants: validation against residual volume method. Clinical and Physiological Applications of Electrical Impedance Tomography, edited by D. S. Holder (London: UCL Press).
  • NOUR, S., 1992, Measurement of gastric emptying in infants using APT. PhD Dissertation, (University of Sheffield, UK).
  • LAMONT, G. L., WRIGHTJ. W., EVANS, D. F., and KAPILA, L. A., 1988, An evaluation of applied potential tomography in the diagnosis of infantile hypertrophie pyloric stenosis. Clinical Physics and Physiological Measurement, 9A, 65-69.
  • WRIGHT, J. W., EVANS, D. F., BUSH, D., and LEDINGHAM, S., 1993, The effect of nutritient and non-nutrient test meals on gastric emptying as measured by EIT. Clinical and Physiological Applications of Electrical Impedance Tomography, edited by D. S. Holder (London: UCL Press), pp. 100-106.
  • BAXTER, A. J., MANGNALL, Y. F., LOJ, E. J., BROWN, B. H., BARBER, D. C., JOHNSON, A. G., and READ, N. W., 1988, Evaluation of applied potential tomography as a new noninvasive gastric secretion test. GVT, 30, 1730-1735.
  • SMALLWOOD, R. H., NOUR, S., MANGNALL, Y. F., and SMYTHE, A., 1990, Impedance imaging and gastric motility. Clinical and Physiological Applications of Electrical Impedance Tomography, edited by D. S. Holder (London: UCL Press), pp. 145153.
  • SMALLWOOD, R. H., MANGNALL, Y. F., and LEATHARD, A. D., 1994, Transport of gastric contents. Physiological Measurement, 15 (Suppl. 2A), 175-188.
  • METHERALL, P., BARBER, D. C., SMALLWOOD, R. H., and BROWN, B. H., 1996, Three-dimensional electrical impedance tomography. Nature, 380, 509-512.
  • EYUBOGLU, B. M., BROWN, B. H., and BARBER, D. C., 1989, Invivo imaging of cardiac related impedance changes. TRRR Engineering in Medicine & Biology, 8, 39-45.
  • BROWN, B. H., BARBER, D. C., MORICE, A. H., and LEATHARD, A. D., 1994, Cardiac and respiratory related electrical impedance changes in the human thorax. TRRF. Transactions on Biomedical Engineering, 41, 729-734.
  • LEATHARD, A. D., BROWN, B. H., CAMPBELL, J. H., ZHANG, F., MORICE, A. H., and TAYLER, D., 1994, A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboli. Physiological Measurement, 15 (Suppl. 2A), 137-146.
  • HARRIS, N. D., SUGGETT, A. J., BARBER, D. C., and BROWN, B. H., 1987, Applications of applied potential tomography (APT) in respiratory medicine. Clinical Physics and Physiological Measurement, 8 (Suppl. A), 155-165.
  • SERRANO, R. E., CASAS, O., LEMA, B. D., FEIXAS, R., CALAF, N., CASAN, P., and RIU, P. J., 2001, Unilateral lung ventilation assessment by means of impedance tomography in a clinical environment. Proceedings of the XI International Conference on Electrical Bio-impedance, Oslo, June 17-21, ISBN 82 91853 05 3, pp. 433-437.
  • FRERICHS, I., HINZ, J., DUDYKEWCH, T., BODENSTEIN, M., HAN, G., and HELLIGE, G., 2001, Effect of weightlessness on regional lung ventilation determined by functional EIT. Proceedings of the XI International Conference on Electrical Bioimpedance, Oslo, June 17-21, ISBN 8291853 05 3, pp. 439443.
  • LINDLEY, E. J., BROWN, B. H., BARBER, D. C., GRUNDY, D., KNOWLES, R., MCARDLE, F. J., and WILSON, A. J., 1992, Monitoring body fluid distribution in microgravity using impedance tomography (APT). Clinical Physics and Physiological Measurement, 13A, 181-184.
  • VAN GENDERINGEN, H. R., FAES, T. J. C., JANSEN, J. R. C., and HEETHAAR, R. M., 2001, Lung volume estimation by electrical impedance tomography in experimental lung injury. Proceedings of the XI International Conference on Electrical Bio-impedance, Oslo, June 17-21, ISBN 8291853053, pp. 451-457.
  • NOBLE, T. J., MORICE, A. H., CHANNER, K. S., MILNES, P., HARRIS, N. D., and BROWN, B. H., 1999, Monitoring patients with left ventricular failure by electrical impedance tomography. European Journal of Heart Failure, 1, 379-384.
  • CAMPBELL, J. H., HARRIS, N. D., ZHANG, F., MORICE, A. H., and BROWN, B. H., 1994, Detection of changes in thoracic fluid in man using electrical impedance tomography. Clinical Science, 87, 97-101.
  • NEWELL, J. C., ISAACSON, D., SAULNIER, G. J., CHENEY, M., and GISSER, D. G., 1994, Quantitative assessment of pulmonary oedema by impedance imaging. Proceedings of the 3rd meeting of the European Concerted Action on Impedance Tomography, Ankara, Turkey, September.
  • MORICE, A. H., HARRIS, N. D., CAMPBELL, J., ZHANG, F., and BROWN, B. H., 1993, EIT in the investigation of chest disease. Clinical and Physiological Applications of EIT, edited by D. S. Holder (London: UCL Press), pp. 236-242.
  • FRERICHS, L, HAHN, G., SCHIFFMANN, H., BERGER, C., and HELLIGE, G., 1999, Monitoring regional lung ventilation by functional electrical impedance tomography during assisted ventilation. Annals of the New York Academy of Science, 873, 493-505.
  • FRERICHS, L, 2000, Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities. Physiological Measurement, 21, R1-R21.
  • BROWN, B. H., BARBER, D. C., WANG, W., Lu, L., LEATHARD, A. D., SMALLWOOD, R. H., HAMPSHIRE, A. R., MACKAY, R., and HATZIGALANIS, K, 1994, Multi-frequency imaging and modelling of respiratory related electrical impedance changes. Physiological Measurement, 15 (Suppl. 2A), 1-12.
  • BROWN, B. H., LEATHARD, A. D., Lu, L., WANG, W., and HAMPSHIRE, A., 1995, Measured and expected Cole parameters from electrical impedance tomographic spectro scopy images of the human thorax. Physiological Measurement, 16A, 57-67.
  • NOPP, P., HARRIS, N. D., ZHAO, T. X., and BROWN, B. H., 1997, Model for the dielectric properties of human lung tissue against frequency and air content. Medical a? Biological Engineering & Computing, 35, 695-702.
  • BARDIN, V., CHEREPENIN, V., KARPOV, A., KORJENEVSKY, A., KORIENKO, V., KULTUASOV, Y., and MARSHKOV, V., 2001, Static EIT-images of new-born' lungs. Preliminary results. Proceedings of the XI International Conference on Electrical Bioimpedance, Oslo, June 17-21, ISBN 82 91853 05 3, pp. 457460.
  • NOPP, P., HARRIS, N. D., ZHAO, T. X., and BROWN, B. H., 1997, Model for the dielectric properties of human lung tissue against frequency and air content. Medical & Biological Engineering & Computing, 35, 695-702.
  • HAMPSHIRE, A. R., SMALLWOOD, R. H., BROWN, B. H., and PRIMHAK, R. A., 1995, Multi-frequency and parametric EIT images of neonatal lungs. Physiological Measurement, 16 A, 175-189.
  • MARVEN, S. S., HAMPSHIRE, A. R., SMALLWOOD, R. H., BROWN, B. H., and PRIMHAK, R. A., 1996, Reproducibilify of Electrical Impedance Tomographic Spectroscopy (EITS) parametric images of neonatal lungs. Physiological Measurement, 17, 205-212.
  • PRIMHAK, R. A., BROWN, B. H., JACKSON, M. J., MILNES, P., and SMALLWOOD, R. H., 2001, Maturational changes in lung impedance. Proceedings of the XIth International Conference on Electrical Bio-impedance, Oslo, June 17-21, ISBN 82 91853 05 3, pp. 297-300.
  • BROWN, B. H., PRIMHAK, R. A., SMALLWOOD, R. H., MILNES, P., NARRAOOTT, A. J., and JACKSON, M. J., 2002, Neonatal lungs-can absolute lung resistivity be determined noninvasively? Medical & Biological Engineering, 40, 388-394.
  • BROWN, B. H., PRIMHAK, R. A., SMALLWOOD, R. H., MILNES, P., NARRACOTT, A. J., and JACKSON, M. J., 2002, Neonatal lungs-maturational changes in lung resistivity spectra. Medical & Biological Engineering, 40, 506-511.
  • HOLDER, D., 2001, Electrical impedance tomography of brain function: overview and technical considerations. Proceedings of the XI International Conference on Electrical Bioimpedance, Oslo, June 17-21, ISBN 82 91853 05 3, pp. 467472.
  • BOONE, K. G., LEWIS, A. M., and HOLDER, D. S., 1994, Imaging of cortical spreading depression using EIT: implications for localisation of epileptic foci. Physiological Measurement, 15 (Suppl. 2A), 189-190.
  • HOLDER, D. S., RAO, A., and HANQUAN, Y., 1996, Imaging of physiologically evoked responses by electrical impedance tomography with cortical electrodes in the anaesthetised rabbit. Physiological Measurement, 17, A179-A186.
  • BAGSHAW, A. P., EADIE, L. H., BINNIE, C., TIDSWELL, R. J., YERWORTH, R. J., BAYFORD, R. H., and HOLDER, D. S., 2001, Imaging of interictal epileptiform activity using electrical impedance tomography. Proceedings of the XI International Conference on Electrical Bio-impedance, Oslo, June 17-21, ISBN 82 91853 05 3, pp. 473-477.
  • JOSSINET, J., and SCHMITT, M., 1999, A review of parameters for the bioelectrical characterisation of breast tissue. Annals of the New York Academy of Science, 873, 30-41.
  • KORJENEVSKY, A. V., CHEREPENIN, V. A., KARPOV, A., KORNIENKO, V. N., YiJ, S., and KULTIASOV, Y., 2001, An electrical impedance tomography system for 3-D breast tissues imaging. Proceedings of the XI International Conference on Electrical Bio-impedance, Oslo, June 17-21, ISBN 82 91853 05 3, pp. 403-407.
  • TROKHANOVA, O., KARPOV, A., CHEREPENIN, V., KORJENEVSKI, A., KORNIENKO, V., KULTUASOV, Y., and MARUSHKOV, V., 2001, Electro-impedance mammography testing at some physiological women's periods. Proceedings of the XI International Conference on Electrical Bio-impedance, Oslo, June 17-21, ISBN 82 91853 05 3, pp. 461-465.
  • Zou, Y., and Guo, Z., 2002, A review of electrical impedance techniques for breast cancer detection. Medical Engineering & Physics (in the press).
  • OSTERMAN, K. S., PAULSEN, K. D., and HOOPES, P. J., 1999, Application of linear circuit models to impedance spectra in irradiated muscle. Annals of the New York Academy of Science, 873, 21-29.
  • BROWN, B. H., KARATZAS NAKIELNV, R., and CLARKE, R. G., 1988, Determination of upper arm muscle and fat areas using electrical impedance measurements. Clinical Physics & Physiological Measurement, 9, 4755.
  • ELLEBV, B., KNUDSEN, L. F., BROWN, B. H., CROFTS, C. E., WOODS, M. J., and TROWBRIDGE, A. E., 1990, Electrical impedance assessment of muscle changes following exercise. CPPM, 11, 159-166.
  • EYUBOGLU, M., BIRGUL, O., and IDER, Y. Z., 2001, A dual modality system for high resolution-true conductivity imaging. Proceedings of the XI International Conference on Electrical Bio-impedance, Oslo, June 17-21, ISBN 82 91853 05 3, pp. 409-413.
  • VAUHKONEN, P. J., VAUHKONEN, M., SAVOLAINEN, T., and KAIPIO, J. P., 1999, Static three-dimensional electrical impedance tomography. Annals of the New York Academy of Science, 873, 472-481.
  • BAYFORD, R. H., GIBSON, A., TIZZARD, A., LISTON, A., TIDSWELL, T., BAGSHAW, A. P., and HOLDER, D. S., 2001, Modelling of the effect of eye sockets in the human head using I-DEAS and its implications for imaging impedance change using electrical impedance tomography. Proceedings of the XI International Conference on Electrical Bio-impedance, Oslo, June 17-21, ISBN 82 91853 05 3, 391-396.
  • METHERALL, P., BARBER, D. C., SMALLWOOD, R. H., and BROWN, B. H., 1996, Three-dimensional electrical impedance tomography. Nature, 380, 509-512.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.