77
Views
28
CrossRef citations to date
0
Altmetric
Original Article

A semiclosed-loop optimal control system for blood glucose level in diabetics

, &
Pages 189-196 | Published online: 09 Jul 2009

References

  • MCSHANE, M. J., RUSSELL, R. J., PISHKO, M. V., and COTE, G. L., 2000, Glucose monitoring using implanted fluorescent microspheres. JEFF Engineering in Medicine and Biology, November/December, 36 — 45.
  • ENDOCRINE WEB INC., 1998, The Diabetes Center. http:// www.endocrineweb.com.
  • GENNARO, A. R., CHASE, G. D., MARDEROSIAN, A. D., HARVEY, G. R., HUSSAR, D. A., MEDWICK, T. B., RIPPLE, E. J., SCHWARTS, J. B., SWINYARD, E. A. and ZINK, G. L. 1995, Remington: the science and practice of pharmacy, Vol. 1 (Easton, Pennsylvania: MACK Publishing).
  • GENUTH, S., and MARTIN, P., 1991, Control of hyperglycemia in adult diabetics by pulsed insulin delivery. Diabetes, 26, 571 —581.
  • KRAEGEN, E. W., CAMPBELL, L. V., CHIA, Y. O., MELER, H., and LAZARUS, L., 1991, Control of blood glucose in diabetics using an artificial pancreas. Australian & New Zealand journal of Medicine, 7, 280–286.
  • FISHER, M. E., 1991, A semiclosed-loop algorithm for the control of blood glucose levels in diabetics. JEFF Transac-tions on Biomedical Engineering, 38, 157–61.
  • FISHER, M. E., and TEO, K. L., 1989, Optimal insulin infusion resulting from a mathematical model of blood glucose dynamics. JEFF Transactions on Biomedical Engineering, 36, 479— 486.
  • CEnsoEm, D. J., KRAEGEN, E. W., BELL, D. J., and CHIPPS, D. R., 1984, A semi-closed loop computer-assisted insulin infusion system. Medical Journal of Australia, 141, 784— 789.
  • FURLER, S. M., KRAEGEN, E. W., SMALLWOOD, R. H., and CHisHoLm, D. J., 1985, Blood glucose control by inter-mittent loop closure in the basal mode: computer simula-tion studies with a diabetic model. Diabetes care, 8(6), 553 — 561.
  • BERGMAN, R. N., PHILLIPS, L. S., and COBELLI, C., 1981, Physiologic evaluation of factors controlling glucose toler-ance in man: measurement of insulin sensitivity and f3— cell glucose sensitivity from the response to intravenous glucose. Journal of Clinical Investigation, 68, 1456–1467.
  • BERGMAN, R. N., IDER, Y. Z., BOWDEN, C. R., and COBELLI, C., 1979, Quantitative estimation of insulin sensitivity. American Journal of Physiology, 236, 667–677.
  • BouE, V. W., 1961, Coefficients of normal blood glucose regulation. Journal of App lied Physiology, 16, 783–788.
  • ACKERMAN, E., GATEWOOD, L. C., ROSEVEAR, J. W., and MOLNAR, G. D., 1965, Model studies of blood glucose regulation. Bulletin of Mathematical Biophysics, 27, 21–37.
  • HOME, P. D., MASSI-BENEDETTI, M., GILL, G. V., CAPALDO, B., SHEPHERD, G. A. A., and ALBERTI, K. G. M. M., 1982, Impaired subcutaneous absorption of insulin in 'brittle' diabetics. Acta Endocrinologica, 101, 414–420.
  • KRAEGEN, E. W., and CinsoLm, D. J., 1984, Insulin responses to varying profiles of subcutaneous insulin infusion: Kinetic modeling studies. Diabetologia, 26, 208–213.
  • OLLERTON, R. L., 1989, Application of optimal control theory to diabetes mellitus. International Journal of Control, 50, 2503–2522.
  • IBBINI, M. S., and MASADEH, M. A., 2003, A Fuzzy Rule-Based Closed Loop System for Good Glucose Level Regulation in Diabetic Patients. Submitted for publication.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.