References
- Kerkholffs W., Schumacher O., Meyns B., Verbeken E., Leunens V., Bollen H., Reul H. Design, development, and first in vivo results of an implantable ventricular assist device, MicroVad. Artificial Organs 2004; 28: 904–910
- DeBakey M. E., Noon G. P., Teitel E. R. The rotary blood pumps: Lessons learned and future directions. Artificial Organs 2004; 28: 865–868
- American Heart Association. International Cardiovascular Diseases Statistics. Statistical Fact Sheet—Populations. American Heart Association, Dallas, TX 2003; 1–10
- Goldowsky M. Mini hemoreliable axial flow LVAD with magnetic bearings. Parts 1, 2, 3. ASAIO Journal 2002; 48: 96–101
- Mueller J., Nuesser P., Weng Y. The first ventricular cardiac assist device without any wear and tear in a clinical multi-center trial. ASAIO Journal 2003; 49: 162
- Qian K. X., Zeng P., Ru W. M., Yuan H. Y., Feng Z. G., Li L. Permanent magnetic-levitation of rotating impeller: a decisive breakthrough in the centrifugal pump. Journal of Medical Engineering & Technology 2002; 26: 36–38
- Qian K. X., Zeng P., Ru W. M., Yuan H. Y. A novel permanent maglev impeller TAH: Most requirements on blood pumps have been satisfied. Journal of Biomaterials Applications 2003; 18: 53–62
- Mitamura H., Nakamura H., Okamoto E., Yozu R., Kawada S., Kim D. W. Development of the valvo pump: an axial flow pump implanted at the heart valve position. Artificial Organs 1999; 23: 566
- Li G., Zhao H., Zhu X., Ren B. Preliminary in vivo study of an intra-aortic impeller pump driven by an extracorporeal whirling magnet. Artificial Organs 2002; 26: 890
- Yamazaki K., Umezu M., Koyanagi H., Kitamura M., Eishi K., Kawai A., Tagusari O., Niinami H., Akimoto T., Nojiri C., Tsuchiya K., Mori T., Iiyama H., Endo M. A miniature intraventricular axial flow blood pump that is introduced through the left ventricular apex. Transactions of ASAIO 1992; 38: 679–683
- Qian K. X., Wang D. F., Topaz S., Ru W. M., Zeng P., Yuan H. Y., Zwischenberg J. B. World-unique totally implantable trans-ventricular and cross-valvular cannular pump with rolling bearing and purge system for recovery therapy. Journal of Medical Engineering & Technology, in press
- Qian K. X., Wang D. F., Topaz S., Zeng P., Ru W. M., Yuan H. Y., Zwischenberg J. B. World-first implantable aortic valvo-pump (IAVP) with sufficient haemo-dynamic capacity. Journal of Medical Engineering & Technology, 29: 302–304
- Qian K. X. Outer diameter and 31g weight implantable 23 mm valvo-pump for destination therapy. Journal of Engineering in Medicine, submitted. (English edition)
- Qian K. X., Wang S. S., Chu S. H. Streamlined design in impeller type and diaphragm type artificial heart. Chinese Journal of Medical and Biological Engineering 1993; 13: 165
- Qian K. X. An analytical and three-dimensional streamlined design of axial, radial and diagonal impeller pumps. In Proceedings of the 5th Asian Symposium on Fluid Machines; 6–8 October (Seoul) Korean Society of Mechanical Engineering. 1997; 1: 215–221
- Qian K. X., Yuan H. Y., Ru W. M., Zeng P. Experimental method to reveal the effect of rotor magnet size and air gap on artificial heart driving motor torque and efficiency. Journal of Medical Engineering & Technology 2002; 26: 199