References
- Kleesattel C, Gladwell GML. The contact-impedance metre-3. Ultrasonics. 1969;7:57–62.
- Kleesattel C, Gladwell GML. The contact-impedance metre-1. Ultrasonics. 1968;6:175–180.
- Kleesattel C. Contact impedance metre. Part IV. Ultrasonics. 1970;8:39–48.
- Gladwell GML, Kleesattel C. The contact-impedance metre-2. Ultrasonics. 1968;6:244–251.
- Vidic M, Harb SM, Smith ST. Observations of contact measurements using a resonance-based touch sensor. Precision Eng. 1998;22:19–36.
- Daugela A, Fujii H, Misaki A. Non-destructive mechanical contact impedance and compliance testing of rubberlike materials. JSME. 1996;39:640–648.
- Haefliger D, Muenchinger M, Schitter G, et al. An integrated piezo-acoustic shear-force distance sensor with nanometre resolution for a micropipette tool. Sensor Actuat A. 2003;103:353–358.
- Miyoshi T, Masui Y, Terashima K. Development of high-stiffness touch sensor and its application to measuring instruments. Control Eng Pract. 2007;15:851–862.
- Kanda T, Morita T, Kurosawa MK, et al. A flat type touch probe sensor using PZT thin film vibrator. Sensor Actuat A. 2000;83:67–75.
- Kanda T, Kurosawa MK, Higuchi T. Sensitivity of a miniaturized touch probe sensor using PZT thin film vibrator. Ultrasonics. 2002;40:61–65.
- Kanda T, Morita T, Kurosawa MK, et al. A rod-shaped vibro touch sensor using PZT thin film. IEEE Trans Ultrason Ferroelectr Freq Control. 1999;46:875–882.
- Woody SC, Smith ST. Resonance-based vector touch sensors. Precision Eng. 2003;27:221–233.
- Gehin C, Barthod C, Teisseyre Y. Design and characterisation of a new force resonant sensor. Sensor Actuat A. 2000;84:65–69.
- Barthod C, Teisseyre Y, Gehin C, et al. Resonant force sensor using a PLL electronic. Sensor Actuat A. 2003;104:143–150.
- Weinmann M, Radius R, Assmus F, et al. Measuring profile and position by means of vibrating quartz resonators used as tactile and nontactile sensors. Sensor Actuat A. 1993;37–38:715–722.
- Harb SM, Vidic M. Resonator-based touch-sensitive probe. Sensor Actuat A. 1995;50:23–29.
- Muraoka S. Application of a quartz resonator to a force sensor built in a robot finger for use in a grasp or recognition environment. Measurement. 2003;34:229–244.
- Lindahl OA, Constantinou CE, Eklund A, et al. Tactile resonance sensors in medicine. J Med Eng Technol. 2009;33:263–273.
- Omata S, Murayama Y, Constantinou CE. Real time robotic tactile sensor system for the determination of the physical properties of biomaterials. Sensor Actuat A. 2004;112:278–285.
- Murayama Y, Haruta M, Hatakeyama Y, et al. Development of a new instrument for examination of stiffness in the breast using haptic sensor technology. Sensor Actuat A. 2008;143:430–438.
- Lindahl OA, Omata S. Impression technique for the assessment of oedema – comparison with a new tactile sensor that measures physical-properties of tissue. Med Biol Eng Comput. 1995;33:27–32.
- Lindahl OA, Omata S, Angquist KA. A tactile sensor for detection of physical properties of human skin in vivo. J Med Eng Technol. 1998;22:147–153.
- Murayama Y, Omata S. Fabrication of micro tactile sensor for the measurement of micro-scale local elasticity. Sensor Actuat A. 2004;109:202–207.
- Murayama Y, Omata S. Considerations in the design and sensitivity optimization of the micro tactile sensor. IEEE Trans Ultrason Ferroelectr Freq Control. 2005;52:434–438.
- Murayama Y, Constantinou CE, Omata S. Micro-mechanical sensing platform for the characterization of the elastic properties of the ovum via uniaxial measurement. J Biomech. 2004;37:67–72.
- Murayama Y, Kamakura H, Fueta Y, Nakamura H, Mizuno J, Akaishi K, Omata S, Inui H, Watanabe A. Zona pellucida mechanically hardens following fertilisation. Hum Reprod. 2006;21:I102–I10I.
- Itoi F, Himaki T, Kubota C, et al. Differences exist in zona pellucida hardness between in vivo- and in vitro-generated bovine embryos. Reprod Fert Develop. 2007;19:207.
- Murayama Y, Yoshida M, Mizuno J, et al. Elasticity measurement of zona pellucida using a micro tactile sensor to evaluate embryo quality. J Mamm Ova Res. 2008;25:8–16.
- Murayama Y, Constantinou CE, Omata S. Development of tactile mapping system for the stiffness characterisation of tissue slice using novel tactile sensing technology. Sensor Actuat A. 2005;120:543–549.
- Oie T, Moriwaki T, Murayama Y, et al. Evaluation of mechanical properties of in vivo tissue-engineered prosthetic heart valves, “biovalves”. Int J Artif Organs. 2010;33:448.
- Oie T, Murayama Y, Fukuda T, et al. Development of tactile mapping system (TMS): microscale mapping of elasticity in vascular tissue. Int J Artif Organs. 2008;31:639.
- Oie T, Murayama Y, Fukuda T, et al. Local elasticity imaging of vascular tissues using a tactile mapping system. J Artif Organs. 2009;12:40–46.
- Oie T, Suzuki H, Murayama Y, et al. Surface elasticity imaging of vascular tissues in a liquid environment by a scanning haptic microscope. J Artif Organs. 2010;13:121–125.
- Suzuki H, Oie T, Murayama Y, et al. Development of tactile mapping system (tms): surface elasticity mapping of arteries in water. Int J Artif Organs. 2009;32:434.
- Moriwaki T, Oie T, Takamizawa K, et al. Variations in local elastic modulus along the length of the aorta as observed by use of a scanning haptic microscope (SHM). J Artif Organs. 2011;14:276–283.
- Mindlin RD. Compliance of elastic bodies in contact. J Appl Mech. 1949;16:259–268.
- Robertson AI. Forced vertical vibration of a rigid circular disc on a semi-infinite elastic solid. Proc Cambridge Philos Soc. 1966;62:547–553.
- Szilard J. Quicker, simpler hardness testing using ultrasonics. Ultrasonics. 1984;22:174–178.
- Pollard HF. Sound waves in solids. London: Pion Limited; 1977.
- Omata S, Murayama Y, Honda K, inventors; Nihon University, assignee. Operating frequency selection method for hardness measurement system, operating frequency selection apparatus, and hardness measurement system. United States patent US 7,565,841. 2009 Jul 28.