174
Views
1
CrossRef citations to date
0
Altmetric
Research Articles

Microwave sensor for the investigation of glucose-dependent reflection properties in aqueous samples

ORCID Icon, , &
Pages 217-222 | Received 04 Aug 2018, Accepted 04 Aug 2019, Published online: 29 Aug 2019

References

  • Renard E. Monitoring glycemic control: the importance of self-monitoring of blood glucose. Am J Med. 2005;118:12S–19S.
  • Caduff A, Hirt E, Feldman Y, et al. First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system. Biosens Bioelectron. 2003;19:209–217.
  • Caduff A, Livshits L, Hayashi Y, et al. Cell membrane response on d-glucose studied by dielectric spectroscopy. Erythrocyte and ghost suspensions. J Phys Chem B. 2004;108:13827–13830.
  • Tura A, Sbrignadello S, Barison S, et al. Impedance spectroscopy of solutions at physiological glucose concentrations. Biophys Chem. 2007;129:235–241.
  • Sbrignadello S, Tura A, Ravazzani P. Electroimpedance spectroscopy for the measurement of the dielectric properties of sodium chloride solutions at different glucose concentrations. J Spectrosc. 2013;2013:1–6.
  • Park J, Kim CS, Choi B, et al. The correlation of the complex dielectric constant and blood glucose at low frequency. Biosens Bioelectron. 2003;19:321–324.
  • Costanzo S. Loss tangent effect on the accurate design of microwave sensors for blood glucose monitoring. European Conference on Antenna and Propagation (EUCAP); 2017 March 19–24; Paris, France; p. 661–663.
  • Choi H, Nylon J, Luzio S, et al. Design of continuous non-invasive blood glucose monitoring sensor based on a microwave split ring resonator. IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications; Dec 8-10; London; 2014. p. 4–6.
  • Kim NY, Dhakal R, Adhikari KK, et al. A reusable robust radio frequency biosensor using microwave resonator by integrated passive device technology for quantitative detection of glucose level. Biosens Bioelectron. 2015;67:687–693.
  • Baghbani R, Rad MA, Pourziad A. Microwave sensor for non-invasive glucose measurements design and implementation of a novel linear. IET Wirel Sens Syst. 2015;5:51–57.
  • Jean BR, Green EC, McClung MJ. A microwave frequency sensor for non-invasive blood glucose measurement. IEEE Sensors Applications Symposium; 2008 Feb 12–14; Atlanta, Georgia. IEEE; 2008. p. 4–7.
  • Hofmann M, Fischer G, Weigel R, et al. Microwave-based noninvasive concentration measurements for biomedical applications. IEEE Trans Microwave Theory Techn. 2013;61:2195–2204.
  • Yilmaz T, Brizzi A, Foster R, et al. A patch resonator for sensing blood glucose changes; 2014 31th URSI General Assembly and Scientific Symposium; 2014 Aug 16–23; Beijing, China. URSI GASS; 2014. p. 1–4.
  • Schwerthoeffer U, Weigel R, Kissinger D. Microwave sensor for precise permittivity characterization of liquids used for aqueous glucose detection in medical applications. Microw Conf. 2014;1:1–2.
  • IEEE standard for safety levels with 3 kHz to 300 GHz frequency electromagnetic fields, respect to human exposure to radio amendment; 2010 March 16, IEEE.
  • Meriakri VV, Chigrai EE, Kim D, et al. Dielectric properties of glucose solutions in the millimetre-wave range and control of glucose content in blood. Meas Sci Technol. 2007;18:977–982.
  • Caduff A, Talary MS, Feldman Y. Comment on experimental methods and conclusions of impedance spectroscopy of solutions at physiological glucose concentrations by A. Tura, S. Sbrignadello, S. Barison, S. Conti, G. Pacini. Biophys Chem. 2008;132:165–166.
  • Yoon G. Dielectric properties of glucose in bulk aqueous solutions: influence of electrode polarization and modeling. Biosens Bioelectron. 2011;26:2347–2353.
  • Satish S, Malik K, Sen S, et al. Measurement of dielectric properties of ringer lactate solution with respect to d-glucose. IEEE International Conference on Electrical, Computer and Communication Technologies (ICECCT); 2015 Mar 05–07; Coimbatore, Tamil Nadu, India; 2015. p. 1–4.
  • Satish S, Sen K, Anand S. Determination of glucose-dependent dielectric properties of ringer lactate using open-ended coaxial probe method. MAPAN. 2016;31:225–230.
  • Satish, K. Sen, and S. Anand. Impedance spectroscopy of aqueous solution samples of different glucose concentrations for the exploration of non-invasive- continuous-blood glucose monitoring, Mapan-JMSI. 2018;33(2):185–190.
  • Satish S., Sen K, Anand S. Design of microstrip sensor for non invasive blood glucose monitoring. International Conference on Emerging Trends & Innovation in ICT (ICEI); 2017 Feb 3–5; Pune, India; 2017. p. 5–8.
  • Garg R, Bhartia P, Bahl I, et al. Microstrip antenna design handbook. Norwood: Artech House; 2001.
  • Balanis CA. Advanced engineering electromagnetics. New York: John Wiley & Sons, Inc.; 1989.
  • Hammerstad E. Equations for microstrip circuit design. European Microwave Conference; 1975 Sep 1–4; Hamburg, Germany; 1975. p. 268–272.
  • Balanis CA. Antenna theory analysis and design. 3rd ed. Hoboken, New Jersey: John Wiley & Sons, Inc.; 2005.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.