151
Views
2
CrossRef citations to date
0
Altmetric
Innovations

Biomedical invasive pressure sensor coatings: calibration and waveform perspectives

, ORCID Icon & ORCID Icon
Pages 203-209 | Received 08 Mar 2020, Accepted 20 Apr 2020, Published online: 05 Jun 2020

References

  • Zhou G, Wang Y, Cui L. Biomedical sensor, device and measurement systems. Adv Bioeng. 2015; [cited 2020 Feb 3]; Available from: https://www.intechopen.com/books/advances-in-bioengineering/biomedical-sensor-device-and-measurement-systems.
  • Galiè N, Humbert M, Vachiery J-L, et al. 2015 ESC/ERS guidelines for the diagnosis and treatment of pulmonary hypertension: the Joint Task Force for the Diagnosis and Treatment of Pulmonary Hypertension of the European Society of Cardiology (ESC) and the European Respiratory Society (ERS): Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC), International Society for Heart and Lung Transplantation (ISHLT). Eur Heart J. 2016;37(1):67–119.
  • Balestrieri E, Rapuano S. Calibration of automated non invasive blood pressure measurement devices. In: Mukhopadhyay SC, Lay-Ekuakille A, editors. Advances in biomedical sensing, measurements, instrumentation and systems. Berlin, Heidelberg: Springer; 2010. p. 281–304.
  • Tolonen H, Koponen P, Naska A, et al. Challenges in standardization of blood pressure measurement at the population level. BMC Med Res Methodol. 2015;15(1):15.
  • Pickering TG, Hall JE, Appel LJ, et al. Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Circulation. 2005;111(5):697–716.
  • Rithalia S, Sun M, Jones R. Blood pressure measurement. In: Webster J, editor. The Measurement, Instrumentation and Sensors Handbook. Boca Raton, FL, USA: CRC Press LLC; 1999.
  • Dyer I, Williams DJ. Common errors in clinical measurement. Anaesth Intens Care Med. 2005;6(12):405–407.
  • Al-Zaben A, Arafat I. Estimation and compensation of a biomedical sensor’s response delay using extended Kalman filter. Proceedings of the 2016 3rd Middle East Conference on Biomedical Engineering (MECBME), Beirut, Lebanon; 2016; 42–45.
  • Wenzel MJ, Mensah-Brown A, Josse F, et al. Online drift compensation for chemical sensors using estimation theory. IEEE Sensors J. 2011;11(1):225–232.
  • Sasaki I, Josowicz M, Janata J, et al. Enhanced performance of a filter-sensor system. Analyst. 2006;131(6):751–756.
  • Wenzel MJ, Josse F, Yaz E, et al. Rapid detection of analytes with improved selectivity using coated microcantilever chemical sensors and estimation theory. Proceedings of the Sensors. Atlanta, GA, USA: IEEE; 2007; 91–94.
  • Qin Y, Howlader MMR, Deen MJ, et al. Polymer integration for packaging of implantable sensors. Sens Actuators, B. 2014;202:758–778.
  • Jiang G, Zhou DD. Technology advances and challenges in hermetic packaging for implantable medical devices. New York, NY: Springer; 2009.
  • Deen MJ, Murji R, Fakhr A, et al. Low-power CMOS integrated circuits for radio frequency applications. IEE Proc Circuits Devices Syst. 2005;152(5):509–522.
  • Zigiotti GL, Cavarretta S, Morara M, et al. Standard enucleation with aluminium oxide implant (bioceramic) covered with patient’s sclera. Sci World J. 2012;2012:1–4.
  • Ljung R, Petrini P, Lindgren AK, et al. Implantable central venous catheter facilitates prophylactic treatment in children with haemophilia. Acta Paediatr. 1992;81(11):918–920.
  • Donaldson PE. The Cooper cable: an implantable multiconductor cable for neurological prostheses. Med Biol Eng Comput. 1983;21(3):371–374.
  • Boock R, Rixman M. Silicone based membranes for use in implantable glucose sensors; 2013 [cited 2020 Feb 3]. Available from: https://patents.google.com/patent/US8543184B2/en.
  • Kim J, Lee H, Cha S, et al. Fabrication and evaluation of implantable pressure sensor using strain gauge. Proceedings of the The 5th 2012 Biomedical Engineering International Conference, Ubon Ratchathani, Thailand; 2012; 1–4.
  • Gwon TM, Min KS, Kim JH, et al. Fabrication and evaluation of an improved polymer-based cochlear electrode array for atraumatic insertion. Biomed Microdevices. 2015;17(2):32.
  • Boeser F, Ordonez J, Schuettler M, et al. Non-hermetic encapsulation for implantable electronic devices based on epoxy. Conf Proc IEEE Eng Med Biol Soc. 2015;2015:809–812.
  • Trantidou T, Prodromakis T, Toumazou C. Oxygen plasma induced hydrophilicity of Parylene-C thin films. Appl Surf Sci. 2012;261:43–51.
  • Sun Y, Lacour SP, Brooks RA, et al. Assessment of the biocompatibility of photosensitive polyimide for implantable medical device use. J Biomed Mater Res. 2009;90A(3):648–655.
  • Wang N, Burugapalli K, Song W, et al. Electrospun fibro-porous polyurethane coatings for implantable glucose biosensors. Biomaterials. 2013;34(4):888–901.
  • de Vecchi A, Clough RE, Gaddum NR, et al. Catheter-induced errors in pressure measurements in vessels: an in-vitro and numerical study. IEEE Trans Biomed Eng. 2014;61(6):1844–1850.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.