References
- CHANDRAN, K. B., and YEARWOOD, T. L. P., 1983, Pulsatile flow experiments on heart valve prosthesis. Journal of Medical and Biological Engineering and Computing, 21, 529 — 537.
- CHANDRAN, K. B., and CABELL, G. N., 1984, Pulsatile flow past aortic valve bioprostheses in a model of human aorta. Journal of Biornechanics, 17(8), 609–619.
- IMACHI, K., FUJMASA, I., MABUCHI, K, CHINZEI, T., ABE, Y, and MADEA, K., 1988, A newly designed Jellyfish valve for an artificial heart blood pump. Transactions of American Society of Artificial Internal Organs, 34, 726–728.
- IMACHI, K., MABUCHI, K., CHINZEI, T., ABE, Y, IMANISHI, K., YONEZAWA, T., and MAEDA, K., 1989. In vitro and in vivo evaluation of a Jellyfish valve for practical use. Transactions of American Society of Artificial Internal Organs, 35, 298–301.
- DELLSPERGER, K. C., WIETING, D. W., DEBRA, A., BAEHR, B. S., ROBER, J., BARD, B. S., BURGGER, J. P., and HARRISON, M. D., 1983. Regurgitation of prosthetic heart valve: dependence on heart rate and cardiac output. The American Journal of Cardiology, 51, 321 —328.
- BLACK, M. M., 1991, Design and flow characteristics. Replacement Cardiac Valves (New York: Pergamon Press, Inc.), pp. 1–20.
- TEUEIRA, F. J., and MIKHAIL, A. A., 1992, Cardiac valve replacement with mechanical prosthesis: current status and trends. Advances in Cardiovascular Engineering, edited by Hwang et al. (New York: Plenum Press), pp. 197–226.
- KNOTT, E., REUL, H., KNO CH, M., STEINSEIFER, U., and RAU, G., 1988, In vitro comparison of aortic heart valve prostheses. Part I: mechanical valves. Journal of Thoracic and Cardiovascular Surgery, 96, 952–961.
- BALDWIN, J. T., DEUTSCH, S., PERIE, H. L., and TARBELL, J. M., 1993, Determination of principal Reynolds stresses in pulsatile flows after elliptical filtering of discrete velocity measurements. Transactions of American Society of Mechanical Engineering, 115, 396–403.
- SAKHAEIMANESH, A. A., MORSI, Y S., and TANSLEY, G. D., 1995, In Vitro steady flow velocity and shear stress measurements in the vicinity of a Jellyfish valve. Proceeding of the Twelfth Australasian Fluid Mechanics Conference, Sydney, Australia, 10–15 Dec., 1995 (Australia: University of Sydney) Vol. 2, pp. 887–890.
- SCHOEPHOERSTER, R. T., and CHANDRAN, K. B., 1991, Velocity and turbulence measurements past mitral valve prostheses in a model left ventricle. Journal of Biornechanics, 27, 549 — 562.
- IMAcHI, K, MABUCHI, K., CHINZEI, T., ME, Y, IMANISHI, K., and YoNEZAWA, T., 1992, Fabrication of a Jellyfish valve for use in an artificial heart. Transactions of American Society of Artificial Internal Organs, 38, M237 —M242.
- BLUESTEIN, M., and MOCKROS, L. F., 1969, Haemolytic effects of energy dissipation in flowing blood. Medical and Biological Engineering and Computing, 7, 1–16.
- BALDWIN, J. T., DEUTSCH, S., GESELOWITZ, D. B., and TARBELL, J. M., 1990, Estimation of Reynolds stresses within the Penn State left ventricular assist device. Transactions of American Society of Artificial Internal Organs, 36, M274 —M278.
- VAN DEN BRINK, R. B. A., VISSER, C. A., BASART, D. C., DUREN, D. R., DE JONG, A. P., and DUNNING, A. J., 1989, Comparison of transthoracic and transesophageal color Doppler flow imaging in patients with mechanical prostheses in mitral valve position. Americarn Journal of Cardiology, 63, 1471.