References
- PIERARD, G. E., 1988, A critical approach of in vivo mechanical testing of the skin. Cutaneous investigation in health and disease: non invasive methods and instrumenta-tion, edited by J. L. Lévéque, (New York, Dekker), pp. 215–240.
- WHITE, D. J., and SCHNUR, P. L., 1995, Striae distensae after augmentation mammoplasty. Annal of Plastic Surgery, 34, 16–22.
- CUA, A. B., WILHELM, K. P., and MAIBACH, H. I., 1990, Elastic properties of human skin: relation to age, sex, and anatomical region. Archives of Dermatological Research, 282, 283–288.
- DELEIXHE-MAUHIN, F., PIERARD-FRANCHIMONT, C., RORIVE, G., and PIERARD, G. E., 1994, Influence of chronic haemodia-lysis on the mechanical properties of skin. Clinical and Experimental Dermatology, 19, 130–133.
- AURIOL, F., VAILLANT, L., PELUCIO-LOPES, C., MACHET, L., DIRIDOLLOU, S., BERSON, M., and LORETTE, G., 1994, Study of cutaneous extensibility in lymphoedema of the lower limbs. British Jaumal of Dermatology, 131, 265–269.
- PIERARD, G. E., NIKKELS-TASSOUDB, N., and PIERARD-FRANCHI-MONT, C., 1995, Influence of the test area on the mechanical properties of skin. Dermatology, 191, 9–15.
- VIATOUR, M., HENRY, F., and PIERARD, G. E., 1995, A computerized analysis of intrinsic forces in the skin. Clinical and Experimental Dermatology, 20, 308–312.
- PIERARD, G. E., and HENRY, F., 1995, Essai de classement catégoriel des propriétés biomécaniques de la peau. Evaluations par la méthode de succion. Nouvelles Dermato-logiques, 14, 630–636.
- ISHIAWA, T., and TAMURA, T., 1996, Measurement of skin elastic properties with a new suction device: systemic sclerosis. Journal of Dermatology, 23, 165–168.
- FONG, S. S. L., HUNG, L. K., and CHENG, J. C. Y, 1997, The cutometer and ultrasonography in the assessment of postburn hypertrophic scar. A preliminary study. Burns, 23, s12—s18.
- PIERARD, G. E., and LAPIERE, Ch. M., 1977, Physiopatholo-gical variations in the mechanical properties of skin. Archives of Dermatological Research, 260, 231–239.
- LEVEQUE, J. L., de RIGAL, J., AGACHE, P. G., and MONNEUR, C., 1980, Influence of ageing on the in vivo extensibility of human skin at a low stress. Archives of Dermatological Research, 260, 127–135.
- HENRY, F., PIERARD-FRANCHIMONT, C., PANS, A., and PIERARD, G. E., 1997, Striae distensae of pregnancy. An in vivo biomechanical evaluation. InJournal of Dermatol-ogy, 36, 506–508.
- PIERARD-FRANCHIMONT, C., HENRY, F., and PIERARD, G. E., 1997, Mechanical properties of primary anetoderma in a child. Skin Research and Technology, 3, 81–83.