Publication Cover
Hemoglobin
international journal for hemoglobin research
Volume 41, 2017 - Issue 2
271
Views
4
CrossRef citations to date
0
Altmetric
Short Communication

Detection of Hb Rothschild HBB: c.[112T>A or 112T>C], Through High Index of Suspicion on Abnormal Pulse Oximetry

, , , &
Pages 137-139 | Received 24 Feb 2017, Accepted 01 Apr 2017, Published online: 16 Jun 2017

References

  • Neff TA. Routine oximetry. A fifth vital sign? Chest. 1988;94(2):227.
  • Gacon G, Belkhodja O, Wajcman H, et al. Structural and functional studies of Hb Rothschild β37(C3)Trp→Arg. A new variant of the α1β2 contact. FEBS Lett. 1977;82(2):243–246.
  • Sharma VS, Newton GL, Ranney HM, et al. Hemoglobin Rothschild (β37(C3)Trp→Arg): high/low affinity hemoglobin mutant. J Mol Biol. 1980;144(3):267–280.
  • Perutz FM, Muirhead H, Cox JM, et al. Three-dimensional Fourier synthesis of horse oxyhaemoglobin at 2.8 Å resolution: the atomic model. Nature. 1968;219(5150):131–139.
  • Craik CS, Vallette I, Beychok S, et al. Refolding defects in Hemoglobin Rothschild. J Biol Chem. 1980;255(13):6219–6223.
  • Kavanaugh JS, Rogers PH, Case DA, et al. High-resolution X-ray study of deoxyhemoglobin Rothschild 37 β Trp→Arg: a mutation that creates an intersubunit chloride-binding site. Biochemistry. 1992;31(16):4111–4121.
  • Rivetti C, Mozzarelli A, Rossi GL, et al. Effect of chloride on oxygen binding to crystals of Hemoglobin Rothschild (β37 Trp→Arg) in the T quaternary structure. Biochemistry. 1993;32(25):6411–6418.
  • Clark BE, Thein SL. Molecular diagnosis of haemoglobin disorders. Clin Lab Haematol. 2004;26(3):159–176.
  • Barker SJ, Tremper KK, Hyatt JH. Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry. Anesthesiology. 1989;70(1):112–117.
  • Eisenkraft JB. Pulse oximeter desaturation due to methemoglobinemia. Anesthesiology. 1988;68(2):279–282.
  • Barker S, Tremper K. The effect of carbon monoxide inhalation on pulse oximetry and transcutaneous pO2. Anesthesiology. 1987;66(5):677–679.
  • Cote CJ, Goldstone EA, Fuchsman WH, et al. The effect of nail polish on pulse oximetry. Anesth Analg. 1988;67(7):683–686.
  • Hanowell L, Eisele JH Jr, Downs D. Ambient light affects pulse oximeters. Anesthesiology. 1987;67(5):864–865.
  • Bruns CM, Thet LA, Woodson RD, et al. Hemoglobinopathy case finding by pulse oximetry. Am J Hematol. 2003;74(2):142–143.
  • Hladik A, Lynshue K. Dyshemoglobinemias and pulse oximetry: a therapeutic challenge. J Pediatr Hematol Oncol. 2008;30(11):850–852.
  • Shirasawa T, Izumizaki M, Suzuki Y, et al. Oxygen affinity of hemoglobin regulates O2 consumption, metabolism, and physical activity. J Biol Chem. 2003;278(7):5035–5043.
  • Stamatoyannoupoulos G, Parer JT, Finch CA. Physiologic implications of a hemoglobin with decreased oxygen affinity (Hemoglobin Seattle). N Engl J Med. 1969;281(17):916–919.
  • Berjis M, Sharma VS. Double mixing stopped-flow method for the study of equilibria and kinetics of dimer-tetramer association of hemoglobins: studies on Hb Carp, Hb A, and Hb Rothschild. Anal Biochem. 1991;196(2):223–228.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.