References
- Austin J, Gupta A, McDonnell R, et al. A novel microwave sensor to determine particulate blend composition on-line. Anal Chim Acta. 2014;819:82–93.
- Gupta A, Austin J, Davis S, et al. A novel microwave sensor for real-time online monitoring of roll compacts of pharmaceutical powders online—a comparative case study with NIR. J Pharm Sci. 2015;104:1787–1794.
- Peters J, Taute W, Bartscher K, et al. Design, development and method validation of a novel multi-resonance microwave sensor for moisture measurement. Anal Chim Acta. 2017;961:119–127.
- Peters J, Bartscher K, Döscher C, et al. In-line moisture monitoring in fluidized bed granulation using a novel multi-resonance microwave sensor. Talanta. 2017;170:369–376.
- Hinz T, Menke F, Eggers R, et al. Development of a microwave moisture sensor for application in the food industry. LWT Food Sci Technol. 1996;29:316–325.
- Kent M, Knöchel R, Daschner F, et al. Composition of foods including added water using microwave dielectric spectra. Food Control. 2001;12:467–482.
- Knöchel R, Daschner F, Taute W. Resonant microwave sensors for instantaneous determination of moisture in foodstuffs. Food Control. 2001;12:447–458.
- Okamura S. Microwave technology for moisture measurement. Subsurf Sens Technol Appl. 2000;1:205–227.
- Kaatze U, Hübner C. Electromagnetic techniques for moisture content determination of materials. Meas Sci Technol. 2010;21:082001.
- Gradinarsky L, Brage H, Lagerholm B, et al. In situ monitoring and control of moisture content in pharmaceutical powder processes using an open-ended coaxial probe. Meas Sci Technol. 2006;17:1847.
- Buschmüller C, Wiedey W, Döscher C, et al. In-line monitoring of granule moisture in fluidized-bed dryers using microwave resonance technology. Eur J Pharm Biopharm. 2008;69:380–387.
- Buschmüller C, Wiedey W, Döscher C, et al. In-line monitoring of granule moisture and temperature throughout the entire fluidized-bed granulation process using microwave resonance technology: part I. Pharm Ind 2009;71:1403–1408.
- Buschmüller C, Wiedey W, Döscher C, et al. In-line monitoring of granule moisture and temperature throughout the entire fluidized-bed granulation process using microwave resonance technology: part II. Pharm Ind. 2009;71:6–12.
- Lourenço V, Herdling T, Reich G, et al. Combining microwave resonance technology to multivariate data analysis as a novel PAT tool to improve process understanding in fluid bed granulation. Eur J Pharm Biopharm. 2011;78:513–521.
- Lourenço V, Lochmann D, Reich G, et al. A quality by design study applied to an industrial pharmaceutical fluid bed granulation. Eur J Pharm Biopharm. 2012;81:438–447.
- Roßteuscher-Carl K, Fricke S, Hacker MC, et al. Influence of in line monitored fluid bed granulation process parameters on the stability of ethinylestradiol. Int J Pharm. 2015;496:751–758.
- Ennis BJ, Litster JD. Principles of size enlargement. In: Perry R, Green D, editors. Perry’s chemical engineers’ handbook. McGraw-Hill, New York; 1997. p. 73–82, Section 21.
- Iveson SM, Litster JD, Hapgood K, et al. Nucleation, growth and breakage phenomena in agitated wet granulation processes: a review. Powder Technol. 2001;117:3–39.
- Watano S, Terashita K, Miyanami K. Development and application of infrared moisture sensor to complex granulation, Bulletin of University of Osaka Prefecture. Ser A Eng Nat Sci. 1991;39:187–197.
- Watano S, Sato Y, Miyanami K. Application of fuzzy logic to moisture control in fluidized bed granulation. J Chem Eng Japan. 1995;28:282–287.
- Frake P, Greenhalgh D, Grierson SM, et al. Process control and end-point determination of a fluid bed granulation by application of near infra-red spectroscopy. Int J Pharm. 1997;151:75–80.
- Rantanen J, Lehtola S, Rämet P, et al. On-line monitoring of moisture content in an instrumented fluidized bed granulator with a multi-channel NIR moisture sensor. Powder Technol. 1998;99:163–170.
- U.S. Food and Drug Administration, Guidance for Industry: PAT – a framework for innovative pharmaceutical development, manufacturing, and quality assurance; 2004.
- Luypaert J, Massart DL, Vander Heyden Y. Near-infrared spectroscopy applications in pharmaceutical analysis. Talanta. 2007;72:865–883.
- Tok AT, Goh X, Ng WK, et al. Monitoring granulation rate processes using three PAT tools in a pilot-scale fluidized bed. AAPS PharmSciTech. 2008;9:1083–1091.
- Burggraeve A, Monteyne T, Vervaet C, et al. Process analytical tools for monitoring, understanding, and control of pharmaceutical fluidized bed granulation: a review. Eur J Pharm Biopharm. 2013;83:2–15.
- Reich G. Near-infrared spectroscopy and imaging: basic principles and pharmaceutical applications. Adv Drug Deliv Rev. 2005;57:1109–1143.
- Rinnan Å, van den Berg F, Engelsen SB. Review of the most common pre-processing techniques for near-infrared spectra. Trends Anal Chem. 2009;28:1201–1222.
- Meyer W, Schilz W. A microwave method for density independent determination of the moisture content of solids. J Phys D Appl Phys. 1980;13:1823–1830.
- Knöchel R, Taute W, Döscher C. Stray field ring resonators and a novel trough guide resonator for precise microwave moisture and density measurements. Meas Sci Technol. 2007;18:1061–1068.
- Knöchel R, Jahns R, Taute W, et al. A resonator-based moisture meter for high moisture levels. Proceedings of the First European Conference on Moisture Measurement. 2010;53–62.
- Wold S, Esbensen K, Geladi P. Principal component analysis. Chemom Intell Lab Syst. 1987;2:37–52.
- Wold S, Sjöström M, Eriksson L. PLS-regression: a basic tool of chemometrics. Chemom Intell Lab Syst. 2001;58:109–130.