REFERENCES
- J. Hernandez, R. R. Morris, and R. W. Picard, “Call center stress recognition with person-specific models,” Affective Computing and Intelligent Interaction, Vol. 6974, pp. 125–34, 2011. doi: https://doi.org/10.1007/978-3-642-24600-5_16
- F. Mokhayeri, M. R. Akbarzadeh-T, and S. Toosizadeh, “Mental stress detection using physiological signals based on soft computing techniques,” Iranian Conference of Biomedical Engineering (ICBME), Tehran, Iran, 2011.
- S. Thomee, A. Harenstam, and M. Hagberg, “Mobile phone use and stress, sleep disturbances, and symptoms of depression among young adults–a prospective cohort study,” BMC Public Health, Vol. 11, no. 66, 2011.
- M. V. Villarejo, B. G. Zapirain, and A. M. Zorrilla, “A stress sensor based on Galvanic skin response (GSR) controlled by ZigBee,” Sensors, Vol. 12, no. 5, pp. 6075–101, 2012. doi: https://doi.org/10.3390/s120506075
- G. Appelboom, E. Camacho, M. E. Abraham, S. S. Bruce, E. L. Dumont, B. E. Zacharia, and E. S. Connolly, “Smart wearable body sensors for patient self-assessment and monitoring,” Archives of Public Health, Vol. 72, no. 1, pp. 28, 2014. doi: https://doi.org/10.1186/2049-3258-72-28
- P. A. Haddad, A. Servati, S. Soltanian, F. Ko, and P. Servati, “Effects of flexible Dry electrode design on electrodermal activity Stimulus response detection,” IEEE Trans. Biomed. Eng., Vol. 64, no. 12, pp. 2979–87, 2017. doi: https://doi.org/10.1109/TBME.2017.2754220
- C. Setz, B. Arnrich, J. Schumm, R. L. Marca, G. Troster, and U. Ehlert, “Discriminating stress from cognitive load using a wearable EDA device,” IEEE Trans. Inf. Technol. Biomed., Vol. 14, pp. 410–7, 2010. doi: https://doi.org/10.1109/TITB.2009.2036164
- K. Khalfallah, H. Ayoub, J. H. Calvet, X. Neveu, P. Brunswick, S. Griveau, V. Lair, M. Cassir, and F. Bedioui, “Noninvasive galvanic skin sensor for early diagnosis of Sudomotor dysfunction: application to diabetes,” IEEE Sensor J., Vol. 12, pp. 456–63, 2010. doi: https://doi.org/10.1109/JSEN.2010.2103308
- C. Y. Chang, J. Y. Zheng, and C. J. Wang, “Based on support vector regression for emotion recognition using pshysiological signals,” in International Joint conference on Neural Networks, Spain, 2010.
- R. Zangróniz, A. Martínez-Rodrigo, J. M. Pastor, M. T. López, and A. Fernández-Caballero, “Electrodermal activity sensor for Classification of Calm/distress Condition,” Sensors, Vol. 17, no. 10, pp. 2324, 2017. doi: https://doi.org/10.3390/s17102324
- S. Yoon, J. K. Sim, and Y. H. Cho, “A flexible and wearable human stress monitoring patch,” Sci. Rep., Vol. 6, no. 23468, 2016.
- E. Roh, B. U. Hwang, D. Kim, B. Y. Kim, and N. E. Lee, “Stretchable, transparent, ultrasensitive, and patchable strain sensor for human–machine interfaces comprising a nanohybrid of carbon nanotubes and conductive elastomers,” ACS Nano, Vol. 9, no. 6, pp. 6252–61, 2015. doi: https://doi.org/10.1021/acsnano.5b01613
- M. Schubert, M. Schmidt, P. Wolter, H. Malberg, S. Zaunseder, and K. Bock, “Additively manufactured Pneumatically Driven skin electrodes,” Materials. (Basel), Vol. 11, no. 1, pp. 19, 2017. doi: https://doi.org/10.3390/ma11010019
- J. C. Lotters, W. Olthuis, P. H. Veltink, and P. Bergveld, “The mechanical properties of the rubber elastic polymer polydimethylsiloxane for sensor applications,” J. Micromech. Microeng., Vol. 7, no. 145, 1997.
- H. K. Lee, J. Chung, S. I. Chang, and E. Yoon, “Normal and shear force measurement using a flexible polymer tactile sensor with embedded multiple capacitors,” J. Microelectromech. Syst., Vol. 17, pp. 934–42, 2008. doi: https://doi.org/10.1109/JMEMS.2008.921727
- E. S. Hwang, J. H. Seo, and Y. J. Kim, “A polymer-based flexible tactile sensor for both normal and shear load detections and its application for robotics,” J. Microelectromech. Syst., Vol. 16, pp. 556–63, 2007. doi: https://doi.org/10.1109/JMEMS.2007.896716
- M. Paranjape, J. Garra, S. Brida, T. Schneider, R. White, and J. Currie, “A PDMS dermal patch for non-intrusive transdermal glucose sensing,” Sens. Actuators, A, Vol. 104, pp. 195–204, 2003. doi: https://doi.org/10.1016/S0924-4247(03)00049-9
- S. Sang, and H. Witte, “A novel PDMS micro membrane biosensor based on the analysis of surface stress,” Biosens. Bioelectron., Vol. 25, pp. 2420–4, 2010. doi: https://doi.org/10.1016/j.bios.2010.03.035
- C. L. Choong, et al., “Highly stretchable resistive pressure sensors using a conductive elastomeric composite on a micropyramid array,” Adv. Mater., Vol. 26, pp. 3451–8, 2014. doi: https://doi.org/10.1002/adma.201305182
- S. V. R. Kaipu, J. Dsa, D. Sachan, and M. Goswami, “Fabrication of flexible sensors for electrodermal activity measurement,” International Conference on Microelectronics (ICM), IEEE, Beirut, Lebanon, 2017.
- A. Sano and R. W. Picard, “Stress recognition using wearable sensors and mobile phones,” Humaine Association Conference on Affective Computing and Intelligent Interaction (ACII), IEEE, Geneva, Switzerland, 2013.
- W. Simm, M. A. Ferrario, A. Gradinar, M. T. Smith, S. Forshaw, I. Smith, and J. Whittle, “Anxiety and autism: towards personalized digital health,” CHI Conference on Human Factors in Computing Systems, ACM, CA, USA, 2016.
- J. L. Fritz, and M. J. Owen, “Hydrophobic recovery of plasma-treated polydimethylsiloxane,” J. Adhes., Vol. 54, pp. 33–45, 1995. doi: https://doi.org/10.1080/00218469508014379
- S. M. Hong, S. H. Kim, J. H. Kim, and H. I. Hwang, “Hydrophilic surface modification of PDMS using atmospheric RF plasma. Journal of physics: conference series,” IOP Publishing, Vol. 34, 2006.
- M. Van Dooren, J. J. De Vries, and J. H. Janssen, “Emotional sweating across the body: comparing 16 different skin conductance measurement locations,” Physiol. Behav., Vol. 106, pp. 298–304, 2012. doi: https://doi.org/10.1016/j.physbeh.2012.01.020
- W. Boucsein, Electrodermal Activity. 2nd ed. New York, NY: Springer Science & Business Media, 2012.
- V. Justin, “Adaptive threshold based frequency domain filter for periodic noise reduction,” AEU-Int. J. Electron. Commun., Vol. 70, pp. 1692–701, 2016. doi: https://doi.org/10.1016/j.aeue.2016.10.008
- J. Dsa, M. Goswami, B. R. Singh, N. Bhatt, P. Sharma, and M. K. Chauhan, “Design and fabrication of a magnetically actuated non-invasive reusable drug delivery device,” Drug Dev. Ind. Pharm., 1–8, 2018.
- Y. Hao and R. Foster, “Wireless body sensor networks for health monitoring applications,” Phys. Meas., Vol. 29, pp. R27–R56, 2008.
- R. Frischer, et al., “Precise temperature measurement for increasing the survival of newborn babies in incubator environments,” Sensors, Vol. 14, no. 12, pp. 23563–80, 2014. doi: https://doi.org/10.3390/s141223563
- J. Jeon, H.-B.-R. Lee, and Z. Bao, “Flexible wireless temperature sensors based on Ni microparticle-filled binary polymer composites,” Adv. Mater., Vol. 25, no. 6, pp. 850–5, 2013. doi: https://doi.org/10.1002/adma.201204082